Description for Loxeal 30-55
Loxeal 30-55 is a 1-Part Pressure sensitive Modified acrylic Liquid used to Adhere Ceramics, Ferrite and Metal to metalApplication Type Bond 1 Part or 2 Part 1-Part Material Form Liquid Substrate Ceramics, Metal to metal, Some thermoplastics Manufacturer Loxeal Chemistry Modified acrylic, Versatile Cure Method Pressure sensitive, Heat cure, Room temperature curing Cure Temperature (°C) 120, 150, 175 Cure Time (min) 1,440, 20, 10, 5.00 Viscosity (cPs) 50-120 (Pa s), 30-60 (Pa s) Color Amber-like High Temperature Resistance (°C) 120 Low Temperature Resistance (°C) -40 Volume Resistivity (O) 2e13 (Ohm.cm) Durability Tough Can Be Used In Conjunction With These Materials Loxeal Activator -
Technical Data for Loxeal 30-55
Overview
-
Application Type
- Adhesive - Bond
-
1 Part or 2 Part
- 1-Part
-
Material Form
- Liquid
-
Industry
- Other - Used in a variety of structural bonding applications due to its versatile capabilities
-
Chemistry
- Acrylic - Modified acrylic
- Other - Versatile
-
Cure Method
- Pressure Sensitive (min) - Pressure sensitive
- Room Temperature / Air Dry - Room temperature curing
- Heat - Heat cure
-
Color
- Amber - Amber-like
-
Can Be Used In Conjunction With These Materials
- Other - Loxeal Activator
Specifications
Cure Specs
Cure Temperature (°C) 120, 150, 175 Test Method Cure Time (min) 1,440, 20, 10, 5.00 Test Method Viscosity (cPs) 50-120 (Pa s), 30-60 (Pa s) Test Method Fixture or Handling Strength Time (min) <2.00, 10, 20 Test Method Bond Strength
Peel Strength (piw) Outstanding peeling resistance, 0 to 0 3.5-5 (N/25mm) Test Method Shear Strength (psi) 1,740 to 3,626 Test Method Impact Strength (psi) 15 - 25 (kJ/m2) Test Method Tensile Strength (psi) High, 2,176 Test Method Material Resistance
High Temperature Resistance (°C) 120 Test Method Impact Resistance Outstanding impact resistance Low Temperature Resistance (°C) -40 Test Method Conductivity
Dielectric Strength (V/mil) 30 - 50 (KV/mm) Test Method Dielectric Constant 4.6 (Mhz) Test Method Thermal Conductivity (W/m°K) 0.10 Test Method Volume Resistivity (O) 2e13 (Ohm.cm) Test Method Hardness
Durability Tough Flexibility Excellent product flexibility Other Properties
Specific Gravity 1.0 (g/ml) Test Method Coefficient of Thermal Expansion (CTE) 80 e –6 (1/K) Test Method Flash Point (°F) 188.6 Test Method Business Information
Shelf Life Details 1 year (max storage temp. +25°C) in original unopened packaging. Shelf Life Temperature (°F) <77 Shelf Life (mon) 12 -
-
Best Practices for Loxeal 30-55
-
Surface Preparation
Clean and degrease surfaces to bond with Loxeal Cleaner 10.
-
Application
Apply enough product on one surface and apply Loxeal Activator on the other surface. Put together surfaces and put pressure unitl adhesion is reached. Clean the excess of product with organic solvent. For gaps over 0,50 mm put Loxeal Activator on both surfaces. Wait 24 hours to put pieces under stress conditions.
-
Curing
Heat can be used to perform the curing when surfaces conditioning with primer (Activator 20) is not desiderable. Typical heat curing conditions consist of heating parts and maintaining the bond line at temperature given below for the time specified. Optimum conditions for heat cure should be determined on actual assemblies.
-
-
Comparable Materials for Loxeal 30-55
Spec Engine® Results
Closest Results from this Manufacturer
Popular Articles
Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticlePlastic Bonding with Adhesives - Considerations Q&A
Read ArticleWhat Projects Require Custom Adhesive Formulations and Why?
Read ArticleTesting the effectiveness of surface treatments
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Cure Temperature Test Methods
Cure Temperature | Cure Time Test Method |
---|---|
120°C | Heat cure |
150°C | Heat cure |
175°C | Heat cure |
Cure Time Test Methods
Cure Time | Test Method |
---|---|
1,440 min | Final strength |
20 min | Heat cure |
10 min | Heat cure |
5.00 min | Heat cure |
Fixture or Handling Strength Time Test Methods
Fixture or Handling Strength Time | Fixture-Handling Strength Test Method | Fixture-Handling Strength Time Temperature |
---|---|---|
<2.00 min | Curing, Fixture time, Gap 0.05 mm | 20°C |
10 min | Curing, Fixture time, Gap 0.25 mm | 20°C |
20 min | Curing, Fixture time, Gap 0,50 mm | 20°C |
Viscosity Test Methods
Viscosity | Test Method | Temperature |
---|---|---|
50-120 (Pa s) | Spindle 7 @ 20 RPM | 25°C |
30-60 (Pa s) | Spindle 7 @ 2,5 RPM | 25°C |
Impact Strength Test Methods
Impact Strength | Test Method |
---|---|
15 - 25 (kJ/m2) | Cured, ASTM D-950 |
Peel Strength Test Methods
Peel Strength | Test Method |
---|---|
Outstanding peeling resistance | |
0 to 0 piw 3.5-5 (N/25mm) | Cured, ISO 4578 |
Tensile Strength Test Methods
Tensile Strength | Test Method |
---|---|
High | |
2,176 psi | Cured, ISO 6922 |
Shear Strength Test Methods
Shear Strength | Test Method |
---|---|
1,740 to 3,626 psi | Cured, ISO 4587 |
High Temperature Resistance Test Methods
High Temperature Resistance | Test Method |
---|---|
120°C | Cured |
Low Temperature Resistance Test Methods
Low Temperature Resistance | Test Method |
---|---|
-40°C | Cured |
Dielectric Constant Test Methods
Dielectric Constant | Test Method |
---|---|
4.6 (Mhz) | Cured, ASTM D150 |
Dielectric Strength Test Methods
Dielectric Strength | Test Method |
---|---|
30 - 50 (KV/mm) | Cured, ASTM D149 |
Thermal Conductivity Test Methods
Thermal Conductivity | Test Method |
---|---|
0.10 W/m°K | Cured, ASTM C277 |
Volume Resistivity Test Methods
Volume Resistivity | Test Method |
---|---|
2e13 (Ohm.cm) | Cured, ASTM D257 |
Coefficient of Thermal Expansion (CTE) Test Methods
Coefficient of Thermal Expansion (CTE) | CTE Test Method |
---|---|
80 e –6 (1/K) | Cured, ATM D696 |
Flash Point Test Methods
Flash Point | Test Method |
---|---|
87.0°C | TCC |
Specific Gravity Test Methods
Specific Gravity | Temperature |
---|---|
1.0 (g/ml) | 25°C |