Description for Henkel Loctite SF A-534R
• Structural Acrylic Activator • Red Color - Visible Inspection of Activated Surfaces • Nonflammable • Solvent Free (100% Solids) • Environmentally Friendly • Flexible Activator / Adhesive Ratio - Consistent Bond Strength<br/>• User Friendly • Requires No Drying Time •<br/>Brand Loctite, Bondmaster Application Type Activator 1 Part or 2 Part 2-Part Material Form Liquid Substrate Steel (degreased) Manufacturer Henkel Chemistry Acrylic, Contains no solvents, Nonflammable Viscosity (cPs) <50, Very Low Color Red Can Be Used In Conjunction With These Materials Loctite toughened acrylic adhesives -
Technical Data for Henkel Loctite SF A-534R
Overview
-
Application Type
- Accelerator / Activator - Activator
-
1 Part or 2 Part
- 2-Part
-
Material Form
- Liquid
-
Substrate
- Steel - Steel (degreased)
-
Chemistry
- Non-flammable - Nonflammable
- Acrylic
- Solvent-Free - Contains no solvents
-
Application Method
- Brush
- Spray
- Other - Wipe
-
Cure Method
- None
-
Color
- Red
-
Can Be Used In Conjunction With These Materials
- Acrylics - Loctite toughened acrylic adhesives
-
Brand
- Loctite
- Bondmaster
-
Also Known As
- Old Name - Loctite A-534R
Specifications
Cure Specs
Viscosity (cPs) <50, Very Low Test Method Fixture or Handling Strength Time (min) <0.50 Test Method Work / Pot Time (min) 30 Mix Ratio 30:1 (by volume) Bond Strength
Structural/Load-Bearing Structural Shear Strength (psi) >1,203, >2,001 Test Method Other Properties
Specific Gravity 0.980 Test Method Flash Point (°F) >199.4, 209.8 Test Method % Solids (%) 100 Business Information
Shelf Life Details Shelf Life stored at or below 27°C (80°F) Shelf Life Temperature (°F) 81 Shelf Life (mon) 12 Not Good For
Don't Use For Use in pure oxygen systems, Use in oxygen rich systems, Sealant for chlorine, Other strong oxidizing materials -
-
Best Practices for Henkel Loctite SF A-534R
-
Application
Apply LOCTITE® SF A-534R™ by spraying, wiping, or brushing a thin film of the activator onto one of the bonding surfaces.
Apply the Adhesive to the bond area on the non-activated bonding surface.
Join surfaces with sufficient pressure to maintain intimate contact between the parts until handling strength is obtained.
A 15 to 30 second clamp time is usually required for bonding of parts with minimal gap.
-
Mixing
Bondmaster 534R and 533 Adhesive should not be mixed in large quantities, as a vigorous chemical reaction will occur generating a significant amount of heat and vapors.
-
Clean-Up
Unreacted initiator can be cleaned up using acetone, isopropanol, or MEK.
-
-
Comparable Materials for Henkel Loctite SF A-534R
Spec Engine® Results
Popular Articles
Instant Adhesives Guide
Read ArticleInfographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleTesting the effectiveness of surface treatments
Read ArticleElectronic Component Adhesives Guide
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Fixture or Handling Strength Time Test Methods
Fixture or Handling Strength Time | Fixture-Handling Strength Test Method |
---|---|
<0.50 min | ISO 4587, Steel (degreased) using LOCTITE® A-533™, single side activation, Fixture time is defined as the time to develop a shear strength of 0.1 N/mm² |
Viscosity Test Methods
Viscosity | Test Method | Temperature |
---|---|---|
<50 cPs | Brookfield - RVF, Spindle 1, speed 20 rpm | 25°C Room Temperature |
Very Low |
Shear Strength Test Methods
Shear Strength | Type | Cure Time | Cure Temperature | Substrate | Test Method |
---|---|---|---|---|---|
>1,203 psi | Lap Shear Strength | 15 min | 25°C | Steel (degreased) | ISO 4587, single side activation |
>2,001 psi | Lap Shear Strength | 1,440 min | 25°C | Steel (degreased) | ISO 4587, single side activation |
Flash Point Test Methods
Flash Point | Test Method |
---|---|
>93.0°C | Setaflash Closed Cup |
98.8°C | Setaflash Closed Cup |
Specific Gravity Test Methods
Specific Gravity | Temperature |
---|---|
0.980 | 25°C |