High |
|
|
|
|
|
|
1,500 psi |
Overlap shear strength |
|
|
2024 T-3 clad aluminum |
-55°C |
Overlap shear strength was measured on FPL etched 1" wide by 1/2" overlap specimens. The bonds were made from 2 panels of 4" x 7" x 0.063", 2024 T-3 clad aluminum bonded together and cut into 1" wide specimens. The separation rate of the testing jaws was 0.1"/minute. Tests similar to ASTM D-1002. |
2,400 psi |
Overlap shear strength |
|
|
2024 T-3 clad aluminum |
24°C |
Overlap shear strength was measured on FPL etched 1" wide by 1/2" overlap specimens. The bonds were made from 2 panels of 4" x 7" x 0.063", 2024 T-3 clad aluminum bonded together and cut into 1" wide specimens. The separation rate of the testing jaws was 0.1"/minute. Tests similar to ASTM D-1002. |
300 psi |
Overlap shear strength |
|
|
2024 T-3 clad aluminum |
82°C |
Overlap shear strength was measured on FPL etched 1" wide by 1/2" overlap specimens. The bonds were made from 2 panels of 4" x 7" x 0.063", 2024 T-3 clad aluminum bonded together and cut into 1" wide specimens. The separation rate of the testing jaws was 0.1"/minute. Tests similar to ASTM D-1002. |
1,000 psi |
Overlap shear strength |
|
|
Cold rolled steel |
-55°C |
Overlap shear strength was measured on 1" wide by 1/2" overlap bonds of 0.035" cold rolled steel. The steel was prepared by MEK solvent wiping, abrading and MEK wiping. The separation rate of the testing jaws was 0.1"/minute. Tests similar to ASTM D-1002. |
2,000 psi |
Overlap shear strength |
|
|
Cold rolled steel |
24°C |
Overlap shear strength was measured on 1" wide by 1/2" overlap bonds of 0.035" cold rolled steel. The steel was prepared by MEK solvent wiping, abrading and MEK wiping. The separation rate of the testing jaws was 0.1"/minute. Tests similar to ASTM D-1002. |
150 psi |
Overlap shear strength |
|
|
Cold rolled steel |
82°C |
Overlap shear strength was measured on 1" wide by 1/2" overlap bonds of 0.035" cold rolled steel. The steel was prepared by MEK solvent wiping, abrading and MEK wiping. The separation rate of the testing jaws was 0.1"/minute. Tests similar to ASTM D-1002. |
400 psi |
Overlap shear strength |
20 min |
24°C |
2024 T-3 clad FPL etched aluminum |
|
The following data was developed in overlap shear on 2024 T-3 clad FPL etched aluminum curing the adhesive at 75°F (24°C) for the times specified. Test similar to ASTM D-1002. |
500 psi |
Overlap shear strength |
30 min |
24°C |
2024 T-3 clad FPL etched aluminum |
|
The following data was developed in overlap shear on 2024 T-3 clad FPL etched aluminum curing the adhesive at 75°F (24°C) for the times specified. Test similar to ASTM D-1002. |
750 psi |
Overlap shear strength |
60 min |
24°C |
2024 T-3 clad FPL etched aluminum |
|
The following data was developed in overlap shear on 2024 T-3 clad FPL etched aluminum curing the adhesive at 75°F (24°C) for the times specified. Test similar to ASTM D-1002. |
900 psi |
Overlap shear strength |
90 min |
24°C |
2024 T-3 clad FPL etched aluminum |
|
The following data was developed in overlap shear on 2024 T-3 clad FPL etched aluminum curing the adhesive at 75°F (24°C) for the times specified. Test similar to ASTM D-1002. |