• Description for 3M 3532 B/A

    Fast cure semi-rigid urethane • 20-30 min. handling strength • Flexible bonds of many plastics, wood, and rubber

    *See Terms of Use Below

    Application Type Bond
    1 Part or 2 Part 2 Part
    Material Form Liquid
    Substrate Aluminum, PlexiGlass, Metal, Nylon, ABS, Plastic: Polystyrene, Rigid PVC, Cold rolled Steel, Rubber, Wood, FRP, Abraded Aluminum, Lexan, Polycarbonate, Primed Steel, Etched Aluminum, Plastic, Steel, Solvent Wiped Aluminum, Plastics, Abraded Steel , Solvent Wiped Steel, Primed steel
    Manufacturer 3M
    Chemistry Isocyanate, Polyol, Polyurethane, Urethane
    Cure Method Base/Accelerator
    Cure Temperature (°C) 20 to 25, 24
    Cure Time (min) 1,440, Fast
    Viscosity (cPs) 30,000
    Color Brown
    Chemical Resistance Salt spray, Water
    High Temperature Resistance (°C) 82
    Low Temperature Resistance (°C) -40
    Density (g/cm³) 10.3 (weight (lbs/gal)), 11.2 (weight (lbs/gal))
  • Technical Data

    Overview
    • sit lorem nonummy.
      • elit consectetuer ut.
    • nonummy.
      • dolor ipsum.
        adipiscing adipiscing.
        euismod consectetuer.
    • dolore ipsum.
      • tincidunt.
        dolore.
        ut.
    Specifications
    dolor sit sed consectetuer.
    aliquam laoreet amet. dolore. ut erat.
    laoreet ipsum ut. elit ipsum. euismod.
    lorem elit tincidunt. ipsum. sit ipsum.
    sit. sed elit. amet nonummy.
    elit diam elit amet.
    consectetuer consectetuer. nonummy sit euismod. erat sed.
    erat nonummy consectetuer. adipiscing nonummy adipiscing. adipiscing.
    elit tincidunt magna. ut dolore elit. aliquam laoreet.
    laoreet. amet diam consectetuer. elit.
    amet diam. elit ut ut. ipsum.
    nibh nibh. nibh. dolor amet.
    nibh adipiscing aliquam.
    elit dolore. adipiscing. diam sit.
    dolore ut nonummy. dolore adipiscing nonummy. dolor sit.
    tincidunt sed aliquam. amet ut. consectetuer.
    euismod dolor ut dolore. dolore nibh. sit nonummy.
    sed erat diam. ipsum elit. amet.
    sed ut. laoreet euismod. adipiscing erat.
    sit. magna dolor. tincidunt tincidunt.
    nonummy nibh aliquam lorem. elit amet. diam elit.
  • Best Practices

    *See Terms of Use Below

    1. euismod ut consectetuer lorem.

      sit adipiscing aliquam erat nonummy elit ut. consectetuer ipsum tincidunt nibh ipsum elit aliquam. nibh adipiscing nibh laoreet adipiscing dolor nonummy. ipsum euismod dolor adipiscing magna sit ipsum.

    2. ipsum erat tincidunt magna nonummy elit.

      laoreet euismod ut dolore dolore adipiscing adipiscing nibh ipsum elit tincidunt amet. dolor diam tincidunt dolor ut dolore tincidunt tincidunt sit tincidunt nibh dolore. dolore nonummy ipsum ut ipsum lorem erat dolor aliquam diam elit aliquam. adipiscing dolore adipiscing erat nonummy euismod erat adipiscing nibh euismod aliquam diam. erat laoreet dolore nonummy laoreet amet tincidunt dolor ipsum magna erat consectetuer.

    3. ipsum sed nibh consectetuer.

      laoreet magna diam tincidunt sit nibh tincidunt amet amet amet nibh. nibh ut consectetuer sit sed adipiscing ut laoreet consectetuer dolore sed.

      magna dolor aliquam aliquam lorem adipiscing amet sed amet lorem erat. lorem dolor ipsum dolor sed dolore tincidunt ut tincidunt tincidunt aliquam.

  • Comparable Materials

    *See Terms of Use Below

Information provided by Gluespec

Why Register?

  • View Technical Details
  • View Test Methods
  • View Key Specifications
  • View Similar Materials
  • Save your Project Searches

Already registered? Sign in.

Questions? Learn more about Gluespec

Gluespec Poll

What level of expertise do you have in specialty chemicals like adhesives, sealants, conformal coatings, etc.?
Viscosity Test Methods
Viscosity Temperature
30,000 cPs 24°C
Work / Pot Time Test Methods
Work / Pot Time Test Method Temperature
5.00 to 15 min 100 grams mixed at 75°F 24°C: 5-15 min. 24°C
7 min
Shear Strength Test Methods
Shear Strength Type Substrate Test Time Test Temperature Test Method
2,500 psi Overlap shear strength Etched Aluminum -40°C All aluminum data were developed on .063-inch thick 2024 T-3 clad aluminum and all steel data on .035-inch cold rolled steel. Test specimens were 1/2-inch overlap, 1-inch wide with .005-inch thick bondlines pulled at a testing rate of .1-inch/min.
2,000 psi Overlap shear strength Abraded and Solvent Wiped Aluminum -40°C All aluminum data were developed on .063-inch thick 2024 T-3 clad aluminum and all steel data on .035-inch cold rolled steel. Test specimens were 1/2-inch overlap, 1-inch wide with .005-inch thick bondlines pulled at a testing rate of .1-inch/min.
1,000 psi Overlap shear strength Solvent Wiped Aluminum -40°C All aluminum data were developed on .063-inch thick 2024 T-3 clad aluminum and all steel data on .035-inch cold rolled steel. Test specimens were 1/2-inch overlap, 1-inch wide with .005-inch thick bondlines pulled at a testing rate of .1-inch/min.
2,000 psi Overlap shear strength Abraded and Solvent Wiped Steel -40°C All aluminum data were developed on .063-inch thick 2024 T-3 clad aluminum and all steel data on .035-inch cold rolled steel. Test specimens were 1/2-inch overlap, 1-inch wide with .005-inch thick bondlines pulled at a testing rate of .1-inch/min.
1,000 psi Overlap shear strength Solvent Wiped Steel -40°C All aluminum data were developed on .063-inch thick 2024 T-3 clad aluminum and all steel data on .035-inch cold rolled steel. Test specimens were 1/2-inch overlap, 1-inch wide with .005-inch thick bondlines pulled at a testing rate of .1-inch/min.
2,000 psi Overlap shear strength Etched Aluminum 24°C All aluminum data were developed on .063-inch thick 2024 T-3 clad aluminum and all steel data on .035-inch cold rolled steel. Test specimens were 1/2-inch overlap, 1-inch wide with .005-inch thick bondlines pulled at a testing rate of .1-inch/min.
2,000 psi Overlap shear strength Abraded and Solvent Wiped Aluminum 24°C All aluminum data were developed on .063-inch thick 2024 T-3 clad aluminum and all steel data on .035-inch cold rolled steel. Test specimens were 1/2-inch overlap, 1-inch wide with .005-inch thick bondlines pulled at a testing rate of .1-inch/min.
1,000 psi Overlap shear strength Solvent Wiped Aluminum 24°C All aluminum data were developed on .063-inch thick 2024 T-3 clad aluminum and all steel data on .035-inch cold rolled steel. Test specimens were 1/2-inch overlap, 1-inch wide with .005-inch thick bondlines pulled at a testing rate of .1-inch/min.
1,200 psi Overlap shear strength Abraded and Solvent Wiped Steel 24°C All aluminum data were developed on .063-inch thick 2024 T-3 clad aluminum and all steel data on .035-inch cold rolled steel. Test specimens were 1/2-inch overlap, 1-inch wide with .005-inch thick bondlines pulled at a testing rate of .1-inch/min.
700 psi Overlap shear strength Solvent Wiped Steel 24°C All aluminum data were developed on .063-inch thick 2024 T-3 clad aluminum and all steel data on .035-inch cold rolled steel. Test specimens were 1/2-inch overlap, 1-inch wide with .005-inch thick bondlines pulled at a testing rate of .1-inch/min.
300 psi Overlap shear strength Etched Aluminum 82°C All aluminum data were developed on .063-inch thick 2024 T-3 clad aluminum and all steel data on .035-inch cold rolled steel. Test specimens were 1/2-inch overlap, 1-inch wide with .005-inch thick bondlines pulled at a testing rate of .1-inch/min.
300 psi Overlap shear strength Abraded and Solvent Wiped Aluminum 82°C All aluminum data were developed on .063-inch thick 2024 T-3 clad aluminum and all steel data on .035-inch cold rolled steel. Test specimens were 1/2-inch overlap, 1-inch wide with .005-inch thick bondlines pulled at a testing rate of .1-inch/min.
100 psi Overlap shear strength Solvent Wiped Aluminum 82°C All aluminum data were developed on .063-inch thick 2024 T-3 clad aluminum and all steel data on .035-inch cold rolled steel. Test specimens were 1/2-inch overlap, 1-inch wide with .005-inch thick bondlines pulled at a testing rate of .1-inch/min.
100 psi Overlap shear strength Abraded and Solvent Wiped Steel 82°C All aluminum data were developed on .063-inch thick 2024 T-3 clad aluminum and all steel data on .035-inch cold rolled steel. Test specimens were 1/2-inch overlap, 1-inch wide with .005-inch thick bondlines pulled at a testing rate of .1-inch/min.
20 psi Overlap shear strength Solvent Wiped Steel 82°C All aluminum data were developed on .063-inch thick 2024 T-3 clad aluminum and all steel data on .035-inch cold rolled steel. Test specimens were 1/2-inch overlap, 1-inch wide with .005-inch thick bondlines pulled at a testing rate of .1-inch/min.
240 psi Overlap shear strength Nylon -40°C All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
1,240 psi Overlap shear strength Lexan -40°C Denotes substrate failure., All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
620 psi Overlap shear strength Plexiglass -40°C All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
1,660 psi Overlap shear strength FRP -40°C Denotes substrate failure, All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
370 psi Overlap shear strength Rigid PVC -40°C All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
440 psi Overlap shear strength ABS -40°C Denotes substrate failure, All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
330 psi Overlap shear strength Polystyrene -40°C All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
580 psi Overlap shear strength Nylon 24°C All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
1,840 psi Overlap shear strength Lexan 24°C Denotes substrate failure., All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
1,300 psi Overlap shear strength Plexiglass 24°C All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
1,150 psi Overlap shear strength FRP 24°C Denotes substrate failure., All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
960 psi Overlap shear strength Rigid PVC 24°C All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
810 psi Overlap shear strength ABS 24°C All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
530 psi Overlap shear strength Polystyrene 24°C All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
40 psi Overlap shear strength Nylon 82°C All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
125 psi Overlap shear strength Lexan 82°C All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
70 psi Overlap shear strength Plexiglass 82°C All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
180 psi Overlap shear strength FRP 82°C All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
110 psi Overlap shear strength Rigid PVC 82°C All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
300 psi Overlap shear strength ABS 82°C All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
110 psi Overlap shear strength Polystyrene 82°C All data were developed on 1/8-inch thick, 1/2-inch overlap, 1-inch wide specimens with .005-inch thick bondlines that had been abraded and alcohol wiped prior to bonding.
5 psi Overlap shear strength plastic to primed steel 1,800 sec 25°C Specimens: 1/2-inch overlap fiber reinforced plastic to primed steel, 0.032-inch bondline. Specimens were pulled at 2 inches/min.
20 psi Overlap shear strength plastic to primed steel 3,600 sec 25°C Specimens: 1/2-inch overlap fiber reinforced plastic to primed steel, 0.032-inch bondline. Specimens were pulled at 2 inches/min.
90 psi Overlap shear strength plastic to primed steel 7,200 sec 25°C Specimens: 1/2-inch overlap fiber reinforced plastic to primed steel, 0.032-inch bondline. Specimens were pulled at 2 inches/min.
400 psi Overlap shear strength plastic to primed steel 10,800 sec 25°C Specimens: 1/2-inch overlap fiber reinforced plastic to primed steel, 0.032-inch bondline. Specimens were pulled at 2 inches/min.
490 psi Overlap shear strength plastic to primed steel 14,400 sec 25°C Specimens: 1/2-inch overlap fiber reinforced plastic to primed steel, 0.032-inch bondline. Specimens were pulled at 2 inches/min.
560 psi Overlap shear strength plastic to primed steel 18,000 sec 25°C Specimens: 1/2-inch overlap fiber reinforced plastic to primed steel, 0.032-inch bondline. Specimens were pulled at 2 inches/min.
680 psi Overlap shear strength plastic to primed steel 21,600 sec 25°C Specimens: 1/2-inch overlap fiber reinforced plastic to primed steel, 0.032-inch bondline. Specimens were pulled at 2 inches/min.
790 psi Overlap shear strength plastic to primed steel 25,200 sec 25°C Specimens: 1/2-inch overlap fiber reinforced plastic to primed steel, 0.032-inch bondline. Specimens were pulled at 2 inches/min.
1,200 psi Overlap shear strength plastic to primed steel 57,600 sec 25°C Specimens: 1/2-inch overlap fiber reinforced plastic to primed steel, 0.032-inch bondline. Specimens were pulled at 2 inches/min.
1,550 psi Overlap shear strength plastic to primed steel 86,400 sec 25°C Specimens: 1/2-inch overlap fiber reinforced plastic to primed steel, 0.032-inch bondline. Specimens were pulled at 2 inches/min.
0 psi Overlap shear strength plastic to primed steel 600 sec 38°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
240 psi Overlap shear strength plastic to primed steel 1,800 sec 38°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
500 psi Overlap shear strength plastic to primed steel 2,700 sec 38°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
650 psi Overlap shear strength plastic to primed steel 3,600 sec 38°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
140 psi Overlap shear strength plastic to primed steel 600 sec 49°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
480 psi Overlap shear strength plastic to primed steel 1,200 sec 49°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
750 psi Overlap shear strength plastic to primed steel 30 sec 49°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
120 psi Overlap shear strength plastic to primed steel 5.00 sec 66°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
400 psi Overlap shear strength plastic to primed steel 10 sec 66°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
760 psi Overlap shear strength plastic to primed steel 15 sec 66°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
400 psi Overlap shear strength plastic to primed steel 5.00 sec 82°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
660 psi Overlap shear strength plastic to primed steel 10 sec 82°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
900 psi Overlap shear strength plastic to primed steel 15 sec 82°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
340 psi Overlap shear strength plastic to primed steel 2.00 sec 93°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
660 psi Overlap shear strength plastic to primed steel 5.00 sec 93°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
900 psi Overlap shear strength plastic to primed steel 10 sec 93°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
440 psi Overlap shear strength plastic to primed steel 2.00 sec 107°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
760 psi Overlap shear strength plastic to primed steel 5.00 sec 107°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
900 psi Overlap shear strength plastic to primed steel 10 sec 107°C Specimens: 1/2-inch overlap shear, fiber reinforced plastic to primed steel .032-inch bondline. Specimens were placed in an oven at designated temperature for the specified time. Bonds were then cooled for 1 minute and pulled at a rate of 2-inch/min.
Tensile Strength Test Methods
Tensile Strength Cure Time Cure Temperature Test Temperature Test Method
3,000 psi 60 min 121°C 20 to 25°C RT ASTM-D-738 at 2 inches/min.
3,000 psi 30 min 141°C 20 to 25°C RT ASTM-D-738 at 2 inches/min.