• Description for 3M 4932

    White, closed-cell acrylic foam carrier • Good adhesion to polypropylene and many powder paints• Apply as low as 50°F (10°C)

    *See Terms of Use Below

    Chemical Resistance Chemical Resistance: Excellent solvent resistance
    Application Type Bond
    1 Part or 2 Part 1 Part
    Material Form Tape
    Substrate EVA, PolyEthylene, Silicone, Polypropylene, Aluminum, Stainless steel , Galvanized Steel, Enameled Steel, Ceramic, Glass, Polycarbonate, Rigid PVC, Galvanized Steel, Tedlar, Teflon, ABS
    Industry Many exterior bonding applications, Many interior bonding applications
    Manufacturer 3M
    Chemistry Acrylic
    Application Method knife coat, Trowel
    Cure Method Pressure sensitive
    Color White
    High Temperature Resistance (°C) 71, 93
    Density (g/cm³) 0.800
    Key Specifications UL 746C

Popular Articles

Testing the effectiveness of surface treatments

Read Article

What Projects Require Custom Adhesive Formulations and Why?

Read Article

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

An Overview of Fluid Dispensing Systems & How They’re Used

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article

Featured Ads

Gluespec Poll

Which answer best describes a project you are currently working on?
Shear Strength Test Methods
Shear Strength Type Cure Time Substrate Test Time Test Temperature Test Method
High
100 psi Dynamic overlap shear strength 4,320 min Stainless steel 25°C Room Temperature ASTM D-1002 - To stainless steel, room temperature, 1 in2 (6.45 cm2), jaw speed 0.5 in/min (12.7 mm/min.) Peak force to separate is measured. 72 hour dwell.
1500 (grams) Static shear strength Stainless steel 600,000 sec 22°C ASTM D3654 - To stainless steel, tested at various temperatures and gram loadings. 0.5 in2 (3.22 cm2). Will hold listed weight for 10,000 minutes (approximately 7 days). Conversion: 1500 g/0.5 in2 equals 6.6 lb/in2, 500 g/0.5 in2 = 2.2 lb/in2.
500 (grams) Static shear strength Stainless steel 600,000 sec 66°C ASTM D3654 - To stainless steel, tested at various temperatures and gram loadings. 0.5 in2 (3.22 cm2). Will hold listed weight for 10,000 minutes (approximately 7 days). Conversion: 1500 g/0.5 in2 equals 6.6 lb/in2, 500 g/0.5 in2 = 2.2 lb/in2.
Tensile Strength Test Methods
Tensile Strength Cure Time Substrate Test Temperature Test Method
High 25°C Room Temperature
100 psi 4,320 min Aluminum ASTM D-897 - To aluminum, room temperature, 1 in2 (6.45 cm2), jaw speed 2 in/min (50 mm/min.) Peak force to separate is measured. 72 hour dwell.
Peel Strength Test Methods
Peel Strength Type Cure Time Substrate Test Temperature Test Method
High
20 (lb/in) 90° Peel strength 4,320 min Stainless steel 25°C Room Temperature Based on ASTM D3330 -To stainless steel, room temperature, jaw speed 12 in/min (305 mm/min). Average force to remove is measured. 72 hour dwell.
High Temperature Resistance Test Methods
High Temperature Resistance Test Method
71°C Long Term Temperature Tolerance - Maximum temperature where tape supports at least 250 g load per 0.5 in2 in static shear for 10,000 minutes. (Represents continuous exposure for days or weeks).
93°C Short Term Temperature Tolerance - No change in room temperature dynamic shear properties following 4 hours conditioning at indicated temperature with 100 g/static load. (Represents minutes, hours in a process type temperature exposure).