Description for 3M 7993MP Membrane Switch Spacer
Single side spacers aid in the construction of membrane switch circuitry, i.e. to protect leads, hold domes in place, or build your own spacer.Chemical Resistance Excellent, Chemical Resistance: Mild acids, Chemical Resistance: Excellent Solvent, Germicidals, Alkalies, Oil, Gasoline, Kerosene, JP-4 fuel, Cleaning solutions Application Type Bond, Laminating 1 Part or 2 Part 1 Part Material Form Sheet Substrate Aluminum, PET, Metal, Plastic, Polycarbonate, Polyester, Stainless Steel Industry Construction of membrane switch circuitry, i.e. to protect leads, hold domes in place, or build your own spacer Manufacturer 3M Chemistry Hi-Performance Acrylic Ozone Resistance Ozone resistance Oxidation Resistance Oxidation resistance High Temperature Resistance (°C) 149
Popular Articles
Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleAn Overview of Fluid Dispensing Systems & How They’re Used
Read ArticleTesting the effectiveness of surface treatments
Read ArticleWhat Projects Require Custom Adhesive Formulations and Why?
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Peel Strength Test Methods
Peel Strength | Type | Substrate | Test Time | Test Temperature | Test Method |
---|---|---|---|---|---|
40 (oz./in.) | 90° Peel Strength | PET/Stainless Steel | 20 min | ASTM D3330 | |
36 (oz./in.) | 90° Peel Strength | PET/Aluminum | 20 min | ASTM D3330 | |
36 (oz./in.) | 90° Peel Strength | PET/PET | 20 min | ASTM D3330 | |
38 (oz./in.) | 90° Peel Strength | PET/Polycarbonate | 20 min | ASTM D3330 | |
68 (oz./in.) | 90° Peel Strength | PET/Stainless Steel | 4,320 min | 22°C | ASTM D3330 |
64 (oz./in.) | 90° Peel Strength | PET/Aluminum | 4,320 min | 22°C | ASTM D3330 |
46 (oz./in.) | 90° Peel Strength | PET/PET | 4,320 min | 22°C | ASTM D3330 |
51 (oz./in.) | 90° Peel Strength | PET/Polycarbonate | 4,320 min | 22°C | ASTM D3330 |
82 (oz./in.) | 90° Peel Strength | PET/Stainless Steel | 4,320 min | 70°C | ASTM D3330 |
79 (oz./in.) | 90° Peel Strength | PET/Aluminum | 4,320 min | 70°C | ASTM D3330 |
72 (oz./in.) | 90° Peel Strength | PET/PET | 4,320 min | 70°C | ASTM D3330 |
62 (oz./in.) | 90° Peel Strength | PET/Polycarbonate | 4,320 min | 70°C | ASTM D3330 |
Tensile Strength Test Methods
Tensile Strength | Test Temperature | Test Method |
---|---|---|
3,609 psi | 22°C | ASTM D2370 |
Moisture/Humidity Resistance Test Methods
Moisture/Humidity Resistance | Test Method |
---|---|
Moisture resistance | |
7 (days) | |
Humidity Resistance |
Dielectric Constant Test Methods
Dielectric Constant | Temperature | Test Method |
---|---|---|
2.77 | 22°C | ASTM D150 |
Dielectric Strength Test Methods
Dielectric Strength | Test Method |
---|---|
1,700 V/mil | ASTM D149 (Short time method (air)) |
Dissipation Factor Test Methods
Dissipation Factor | Temperature | Test Method |
---|---|---|
0.01200 | 22°C | ASTM D150 |
Insulation Resistance Test Methods
Insulation Resistance | Test Method |
---|---|
6.5 x 10(12) (Ohms) | Mil-I-46058C (100VDC, 60 sec.) |
Surface Resistivity Test Methods
Surface Resistivity | Temperature | Test Method |
---|---|---|
> 5.6e16 (Ohms) | 22°C | ASTM D257 |
Volume Resistivity Test Methods
Volume Resistivity | Temp (°C) | Test Method |
---|---|---|
2.7e15 (Ohm-cm) | 22°C | ASTM D257 |
Coefficient of Thermal Expansion (CTE) Test Methods
Coefficient of Thermal Expansion (CTE) | CTE Temperature (°C) | CTE Test Method |
---|---|---|