1,100 psi |
Overlap shear strength |
>2,880 min |
23°C |
HDPE |
Control - no chemical exposure |
1,209,600 sec |
23°C |
Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
1,075 psi |
Overlap shear strength |
>2,880 min |
23°C |
PE |
100% RH |
1,209,600 sec |
23°C |
Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
1,100 psi |
Overlap shear strength |
>2,880 min |
23°C |
PP |
Water Soak |
1,209,600 sec |
23°C |
Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
750 psi |
Overlap shear strength |
>2,880 min |
23°C |
UHMWPE |
Salt Water Soak (5% by wt.) |
1,209,600 sec |
23°C |
Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
400 psi |
Overlap shear strength |
>2,880 min |
23°C |
LDPE |
100% RH Salt Water Soak (5% by wt.) |
1,209,600 sec |
23°C |
Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
1,525 psi |
Overlap shear strength |
>2,880 min |
23°C |
ABS |
NaOH (10% by wt.) |
1,209,600 sec |
23°C |
Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
850 psi |
Overlap shear strength |
>2,880 min |
23°C |
Polycarbonate |
HCl (16% by vol.) |
1,209,600 sec |
23°C |
Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
950 psi |
Overlap shear strength |
>2,880 min |
23°C |
Plexiglass (PMMA) |
Isopropyl Alcohol |
1,209,600 sec |
23°C |
Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
2,050 psi |
Overlap shear strength |
>2,880 min |
23°C |
PVC |
Antifreeze Coolant |
1,209,600 sec |
23°C |
Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
550 psi |
Overlap shear strength |
>2,880 min |
23°C |
HIPS |
Gasoline |
1,209,600 sec |
23°C |
Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
2,475 psi |
Overlap shear strength |
>2,880 min |
23°C |
Green FRP |
Diesel Fuel |
1,209,600 sec |
23°C |
Cohesive failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
250 psi |
Overlap shear strength |
>2,880 min |
23°C |
PTFE |
Toluene |
1,209,600 sec |
23°C |
Adhesive failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
775 psi |
Overlap shear strength |
>2,880 min |
23°C |
Polystyrene |
Acetone |
1,209,600 sec |
23°C |
Substrate Failure/Bread/Yields, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
650 psi |
Overlap shear strength |
>2,880 min |
23°C |
Glass (3/16" thick) |
|
|
23°C |
Substrate Failure/Bread/Yields, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
1,500 psi |
Overlap shear strength |
>2,880 min |
23°C |
Gel Coat (3/16" thick) |
|
|
23°C |
Substrate Failure/Bread/Yields, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
2,275 psi |
Overlap shear strength |
>2,880 min |
23°C |
Copper (1/16" thick) |
|
|
23°C |
Cohesive failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
2,275 psi |
Overlap shear strength |
>2,880 min |
23°C |
Aluminum (1/16" thick) |
|
|
23°C |
Cohesive failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
2,500 psi |
Overlap shear strength |
>2,880 min |
23°C |
Cold-Rolled Steel (1/32" thick) |
|
|
23°C |
Adhesive failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
2,300 psi |
Overlap shear strength |
>2,880 min |
23°C |
304 Stainless Steel (1/32" thick) |
|
|
23°C |
Cohesive failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
975 psi |
Overlap shear strength |
>2,880 min |
23°C |
HDPE/HDG |
|
|
23°C |
Substrate failure/Break/Yield (HDPE), Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
950 psi |
Overlap shear strength |
>2,880 min |
23°C |
HDPE/Galvanealed |
|
|
23°C |
Substrate failure/Break/Yield (HDPE), Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
950 psi |
Overlap shear strength |
>2,880 min |
23°C |
HDPE/CRS (non-abraded CRS) |
|
|
23°C |
Substrate failure/Break/Yield (HDPE), Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
2,150 psi |
Overlap shear strength |
>2,880 min |
23°C |
Oily HDG |
|
|
23°C |
Cohesive failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
750 psi |
Overlap shear strength |
|
|
HDPE |
|
|
-29°C |
Cohesive failure, Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
1,100 psi |
Overlap shear strength |
|
|
HDPE |
|
|
23°C |
Substrate failure/Break/Yield, Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
700 psi |
Overlap shear strength |
|
|
HDPE |
|
|
49°C |
Cohesive failure, Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
500 psi |
Overlap shear strength |
|
|
HDPE |
|
|
66°C |
Cohesive failure, Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
300 psi |
Overlap shear strength |
|
|
HDPE |
|
|
82°C |
Cohesive failure, Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
975 psi |
Overlap shear strength |
|
|
Green-FRP |
|
|
-29°C |
Adhesive failure, Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
2,475 psi |
Overlap shear strength |
|
|
Green-FRP |
|
|
23°C |
Adhesive failure, Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
1,875 psi |
Overlap shear strength |
|
|
Green-FRP |
|
|
49°C |
Mixed (Mode of AF and CF), Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
1,150 psi |
Overlap shear strength |
|
|
Green-FRP |
|
|
66°C |
Mixed (Mode of AF and CF), Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
750 psi |
Overlap shear strength |
|
|
Green-FRP |
|
|
82°C |
Mixed (Mode of AF and CF), Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
1,100 psi |
Overlap shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Substrate Failure/Break/Yield |
950 psi |
Overlap shear |
|
|
|
|
|
71°C |
Environmental & Chemical Exposure Test on HDPE, Mixed (Mode of AF and CF) |
975 psi |
Overlap shear |
|
|
|
|
|
71°C |
Environmental & Chemical Exposure Test on HDPE, Cohesive Failure |
1,100 psi |
Overlap shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Substrate Failure/Break/Yield |
925 psi |
Overlap shear |
|
|
|
|
|
71°C |
Environmental & Chemical Exposure Test on HDPE, Cohesive Failure |
1,075 psi |
Overlap shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Substrate Failure/Break/Yield |
1,100 psi |
Overlap shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Substrate Failure/Break/Yield |
950 psi |
Overlap shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Substrate Failure/Break/Yield |
1,000 psi |
Overlap shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Substrate Failure/Break/Yield |
325 psi |
Overlap shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Cohesive Failure |
1,050 psi |
Overlap shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Substrate Failure/Break/Yield |
25 psi |
Overlap shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Cohesive Failure |
100 psi |
Overlap shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Cohesive Failure |