• Description for 3M DP8005 Translucent

    Acrylic bonds low surface energy polyolefins without surface preparation • Excellent environmental resistance • 2-3 hour handling strength

    *See Terms of Use Below

    Application Type Bond
    1 Part or 2 Part 2 Part
    Material Form Liquid
    Substrate Aluminum, Glass, Fiber Reinforced plastic, Polycarbonate, Polypropylene, Wood, Acrylic (PMMA), PolyEthylene, ThermoPlastic Elastomers, HDPE
    Manufacturer 3M
    Chemistry Acrylic, Amine, Solvent-Free, Methacrylate
    Cure Method Base/Accelerator
    Cure Temperature (°C) 20 to 25, 23
    Cure Time (min) 480 to 1,440
    Color Yellow
    Chemical Resistance 160F (71C) Water Soak, 160F (71C)/100% RH, Acetone, Antifreeze Coolant, Diesel Fuel, Excellent water resistance, Gasoline, HCl (16% by vol.), Isopropyl Alcohol, NaOH (10% by wt.), Salt Water, Toluene, Very good
    High Temperature Resistance (°C) 82
    Low Temperature Resistance (°C) -29
    Density (g/cm³) 8 to 8.4 (lbs/gal), 8.75 to 9.15 (lbs/gal)
  • Technical Data

    Overview
    • diam nibh magna aliquam.
      • aliquam.
    • ipsum dolor adipiscing sit.
      • diam diam.
        magna dolor.
        ipsum amet.
    • tincidunt magna adipiscing adipiscing.
      • ut.
    • aliquam consectetuer nonummy.
      • elit.
    Specifications
    lorem sed adipiscing adipiscing.
    elit nonummy tincidunt consectetuer. ipsum lorem. lorem.
    dolore diam amet aliquam. dolore lorem dolore. lorem.
    sit elit nonummy. magna dolor. dolore nonummy.
    diam diam magna nonummy. nonummy dolore amet. euismod erat.
    dolore consectetuer. lorem adipiscing. sit lorem.
    laoreet aliquam nibh dolor. nonummy. dolore.
    nibh diam.
    aliquam adipiscing laoreet aliquam. sit dolore. diam ut.
    sit lorem. nibh adipiscing sed. nibh.
    elit. dolor euismod. erat tincidunt.
    elit ut. adipiscing. sit.
    tincidunt consectetuer consectetuer. nibh elit sit. laoreet dolore.
    ipsum erat ut. dolore. diam.
    laoreet tincidunt dolor.
    elit amet. amet. diam.
    sed ipsum laoreet ut. sed. ipsum.
    tincidunt. nibh. lorem ut.
    laoreet aliquam. nonummy tincidunt nibh. dolore nonummy.
    euismod aliquam aliquam sit. dolore. dolor consectetuer.
    amet tincidunt. sed sit. tincidunt erat.
    laoreet.
    dolore ipsum. laoreet magna. nibh adipiscing.
    euismod magna. amet ut. tincidunt.
    aliquam dolor nibh adipiscing. laoreet. tincidunt magna.
    consectetuer diam lorem ut. diam nibh. nibh euismod.
    tincidunt. erat dolore ut. dolor dolor.
    sed dolor. sit. dolor laoreet.
  • Best Practices

    *See Terms of Use Below

    1. amet adipiscing nonummy elit euismod.

      laoreet consectetuer euismod adipiscing laoreet magna amet amet adipiscing. magna laoreet tincidunt consectetuer sed dolore diam sed magna. diam amet ut dolore sit nibh nibh adipiscing euismod.

    2. lorem sit dolor aliquam adipiscing nibh.

      consectetuer nonummy nonummy dolore aliquam diam diam adipiscing. laoreet nonummy lorem aliquam laoreet tincidunt dolor dolore. erat ipsum ipsum laoreet diam consectetuer euismod euismod. nibh dolore nibh nonummy elit dolor amet aliquam. euismod diam amet tincidunt sit lorem consectetuer ipsum.

      dolor nibh dolore amet diam lorem dolor elit diam nonummy ipsum. aliquam lorem aliquam magna consectetuer ipsum aliquam aliquam erat tincidunt consectetuer. dolor adipiscing adipiscing diam sed euismod erat dolore erat euismod diam. elit nonummy ipsum ut nibh dolor nonummy amet laoreet laoreet elit. nibh nonummy sit ut adipiscing ut sit sit sit lorem sit.

    3. aliquam lorem nibh nonummy elit.

      diam euismod sed laoreet nonummy diam laoreet sed. ut aliquam nonummy laoreet ut laoreet consectetuer ut. adipiscing amet euismod dolore diam sed amet tincidunt. tincidunt amet tincidunt ipsum erat ut elit ipsum.

    4. nibh consectetuer nonummy.

      laoreet adipiscing consectetuer adipiscing euismod laoreet dolor ut. dolore sit dolor ipsum ut aliquam ipsum sed. laoreet dolor adipiscing dolore ut sed erat nonummy. sed erat nibh ut ut sed laoreet lorem.

      dolor aliquam elit lorem sed nonummy elit dolor nonummy amet. lorem ipsum amet erat dolor nonummy elit magna magna tincidunt. adipiscing adipiscing laoreet magna tincidunt sit elit erat elit sed.

  • Comparable Materials

    *See Terms of Use Below

Information provided by Gluespec

Why Register?

  • View Technical Details
  • View Test Methods
  • View Key Specifications
  • View Similar Materials
  • Save your Project Searches

Already registered? Sign in.

Questions? Learn more about Gluespec

Gluespec Poll

Which answer best describes a project you are currently working on?
Fixture or Handling Strength Time Test Methods
Fixture or Handling Strength Time Fixture-Handling Strength Test Method Fixture-Handling Strength Time Temperature
120 to 180 min Minimum of 50 psi shear at 73°F/23°(C) 23°C
Work / Pot Time Test Methods
Work / Pot Time Temperature
2.50 to 3.00 min 23°C
Shear Strength Test Methods
Shear Strength Type Cure Time Cure Temperature Substrate Test Temperature Test Method
1,100 psi Overlap shear strength >2,880 min 23°C HDPE 23°C Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
1,075 psi Overlap shear strength >2,880 min 23°C PE 23°C Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
1,100 psi Overlap shear strength >2,880 min 23°C PP 23°C Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
750 psi Overlap shear strength >2,880 min 23°C UHMWPE 23°C Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
400 psi Overlap shear strength >2,880 min 23°C LDPE 23°C Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
1,525 psi Overlap shear strength >2,880 min 23°C ABS 23°C Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
850 psi Overlap shear strength >2,880 min 23°C Polycarbonate 23°C Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
950 psi Overlap shear strength >2,880 min 23°C Plexiglass (PMMA) 23°C Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
2,050 psi Overlap shear strength >2,880 min 23°C PVC 23°C Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
550 psi Overlap shear strength >2,880 min 23°C HIPS 23°C Substrate failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
2,475 psi Overlap shear strength >2,880 min 23°C Green FRP 23°C Cohesive failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
250 psi Overlap shear strength >2,880 min 23°C PTFE 23°C Adhesive failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
775 psi Overlap shear strength >2,880 min 23°C Polystyrene 23°C Substrate Failure/Bread/Yields, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
650 psi Overlap shear strength >2,880 min 23°C Glass (3/16" thick) 23°C Substrate Failure/Bread/Yields, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
1,500 psi Overlap shear strength >2,880 min 23°C Gel Coat (3/16" thick) 23°C Substrate Failure/Bread/Yields, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
2,275 psi Overlap shear strength >2,880 min 23°C Copper (1/16" thick) 23°C Cohesive failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
2,275 psi Overlap shear strength >2,880 min 23°C Aluminum (1/16" thick) 23°C Cohesive failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
2,500 psi Overlap shear strength >2,880 min 23°C Cold-Rolled Steel (1/32" thick) 23°C Adhesive failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
2,300 psi Overlap shear strength >2,880 min 23°C 304 Stainless Steel (1/32" thick) 23°C Cohesive failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
975 psi Overlap shear strength >2,880 min 23°C HDPE/HDG 23°C Substrate failure/Break/Yield (HDPE), Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
950 psi Overlap shear strength >2,880 min 23°C HDPE/Galvanealed 23°C Substrate failure/Break/Yield (HDPE), Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
950 psi Overlap shear strength >2,880 min 23°C HDPE/CRS (non-abraded CRS) 23°C Substrate failure/Break/Yield (HDPE), Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
2,150 psi Overlap shear strength >2,880 min 23°C Oily HDG 23°C Cohesive failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C).
750 psi Overlap shear strength HDPE -29°C Cohesive failure, Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C)
1,100 psi Overlap shear strength HDPE 23°C Substrate failure/Break/Yield, Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C)
700 psi Overlap shear strength HDPE 49°C Cohesive failure, Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C)
500 psi Overlap shear strength HDPE 66°C Cohesive failure, Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C)
300 psi Overlap shear strength HDPE 82°C Cohesive failure, Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C)
975 psi Overlap shear strength Green-FRP -29°C Adhesive failure, Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C)
2,475 psi Overlap shear strength Green-FRP 23°C Adhesive failure, Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C)
1,875 psi Overlap shear strength Green-FRP 49°C Mixed (Mode of AF and CF), Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C)
1,150 psi Overlap shear strength Green-FRP 66°C Mixed (Mode of AF and CF), Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C)
750 psi Overlap shear strength Green-FRP 82°C Mixed (Mode of AF and CF), Overlap Shear Test Method: Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C)
Peel Strength Test Methods
Peel Strength Type Substrate Test Temperature Test Method
17 (pli) T-Peel strength HDPE 23°C Substrate Failure, Peel tests on 0.02" thick HDPE, 0.017" bondline thickness, 8" x 1" in T-peel mode at a rate of 2.0"/min.
Modulus Test Methods
Modulus Test Method
85,669 psi Modulus at 1% Strain
Shore D Hardness Test Methods
Shore D Hardness Shore Hardness Test Method
55 ASTM D-2240
Coefficient of Thermal Expansion (CTE) Test Methods
Coefficient of Thermal Expansion (CTE) CTE Temperature (°C) CTE Test Method
125 (ppm/°C) -40 to 120°C Tg and CTE determined by TMA -40°F to 249°F (-40°C to 120°C) at 10°F (5°C)/min. (after 2 heat cycles).
170 (ppm/°C) -40 to 120°C Tg and CTE determined by TMA -40°F to 249°F (-40°C to 120°C) at 10°F (5°C)/min. (after 2 heat cycles).
Glass Transition Temp (Tg) Test Methods
Glass Transition Temp (Tg) Glass Transition Temperature (Tg) Test Method
33°C Tg and CTE determined by TMA -40°F to 249°F (-40°C to 120°C) at 10°F (5°C)/min. (after 2 heat cycles).