750 psi |
Overlap shear strength |
>2,880 min |
23°C |
UHMWPE |
Control - no chemical exposure |
1,209,600 sec |
23°C |
Substrate Failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
400 psi |
Overlap shear strength |
>2,880 min |
23°C |
LDPE |
100% RH |
1,209,600 sec |
23°C |
Substrate Failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
1,100 psi |
Overlap shear strength |
>2,880 min |
23°C |
HDPE |
Water Soak |
1,209,600 sec |
23°C |
Substrate Failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
1,225 psi |
Overlap shear strength |
>2,880 min |
23°C |
PE |
NaOH (10% by weight) |
1,209,600 sec |
23°C |
Substrate Failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
1,500 psi |
Overlap shear strength |
>2,880 min |
23°C |
PP |
HCI (16% by volume) |
1,209,600 sec |
23°C |
Cohesive failure, Substrate Failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
1,450 psi |
Overlap shear strength |
>2,880 min |
23°C |
ABS |
Isoproyl Alcohol |
1,209,600 sec |
23°C |
Substrate Failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
1,250 psi |
Overlap shear strength |
>2,880 min |
23°C |
Lexan |
Antifreeze Coolan |
1,209,600 sec |
23°C |
Cohesive Failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
1,075 psi |
Overlap shear strength |
>2,880 min |
23°C |
Plexiglass (PMMA) |
Gasoline |
1,209,600 sec |
23°C |
Substrate Failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
2,220 psi |
Overlap shear strength |
>2,880 min |
23°C |
PVC |
Diesel Fuel |
1,209,600 sec |
23°C |
Substrate Failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
575 psi |
Overlap shear strength |
>2,880 min |
23°C |
HIPS |
Toluene |
1,209,600 sec |
23°C |
Substrate Failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
550 psi |
Overlap shear strength |
>2,880 min |
23°C |
PTFE |
Acetone |
1,209,600 sec |
23°C |
Adhesive Failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
2,425 psi |
Overlap shear strength |
>2,880 min |
23°C |
Green FRP |
|
|
23°C |
Mixed (Mode of AF and CF), Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C). |
775 psi |
Overlap shear strength |
>2,880 min |
23°C |
Polystyrene |
|
|
23°C |
Substrate Failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
600 psi |
Overlap shear strength |
>2,880 min |
23°C |
Glass (3/16" thick) |
|
|
23°C |
Substrate Failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
1,550 psi |
Overlap shear strength |
>2,880 min |
23°C |
Gel Coat (3/16" thick) |
|
|
23°C |
Substrate Failure/Break/Yield, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
2,375 psi |
Overlap shear strength |
>2,880 min |
23°C |
Copper (1/16" thick) |
|
|
23°C |
Mixed (Mode of AF and CF), Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
2,200 psi |
Overlap shear strength |
>2,880 min |
23°C |
Aluminum (1/16" thick) |
|
|
23°C |
Cohesive Failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
1,525 psi |
Overlap shear strength |
>2,880 min |
23°C |
Cold-Rolled Steel (1/32" thick) |
|
|
23°C |
Adhesive Failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
900 psi |
Overlap shear strength |
>2,880 min |
23°C |
304 Stainless Steel (1/32" thick) |
|
|
23°C |
Adhesive Failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
200 psi |
Overlap shear strength |
>2,880 min |
23°C |
Acetal |
|
|
23°C |
Adhesive Failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
825 psi |
Overlap shear strength |
>2,880 min |
23°C |
CRS/HDPE (Non-abraded CRS) |
|
|
23°C |
Adhesive Failure to CRS, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
425 psi |
Overlap shear strength |
>2,880 min |
23°C |
Aluminum/HDPE (non-abraded aluminum) |
|
|
23°C |
Adhesive Failure to Al, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
1,225 psi |
Overlap shear strength |
>2,880 min |
23°C |
ED-500 E-coated CRS/HDPE |
|
|
23°C |
Adhesive Failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
1,575 psi |
Overlap shear strength |
>2,880 min |
23°C |
EC 3924 Primed CRS (non-abraded CRS) |
|
|
23°C |
Cohesive Failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
1,450 psi |
Overlap shear strength |
>2,880 min |
23°C |
EC 3924 Primed Al/HDPE (non-abraded Al) |
|
|
23°C |
Cohesive Failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
1,200 psi |
Overlap shear strength |
>2,880 min |
23°C |
DCT 5002X Top Coat CRS/HDPE (non-abraded CRS) |
|
|
23°C |
Top Coat Failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
125 psi |
Overlap shear strength |
>2,880 min |
23°C |
RK8010A Top Coat CRS/HDPE (non-abraded CRS) |
|
|
23°C |
Adhesive Failure, Overlap shear test for adhesion determined in accordance to ASTM D1002. Sampe dimenions were 1" x 4" x 1/8" (unless other thicknesses indicated) with an overlap area of 1" x 1/2". Plastics and glass substrates were cleansed with isopropyl alcohol (IPA) wipes, metal substrates were abraded with 150-grit sandpaper and cleansed with methyl ethyl ketone (MEK) wipes. All bonds were allowed to cure for a minimum of 48 hours at 73°F (23°C) before tested. Data were collected using a Sintech 5GL Mechanical Tester with the 2000-lb or 5000-lb load cells. Test rate was 2"/min. for plastic bonds, and 0.1"/min. for metal and glass bonds at 73°F (23°C) |
1,100 psi |
Overlap Shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Substrate Failure/Break/Yield |
1,000 psi |
Overlap Shear |
|
|
|
|
|
71°C |
Environmental & Chemical Exposure Test on HDPE, Mixed (Mode of AF and CF) |
1,175 psi |
Overlap Shear |
|
|
|
|
|
71°C |
Environmental & Chemical Exposure Test on HDPE, Cohesive Failure |
975 psi |
Overlap Shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Substrate Failure/Break/Yield |
975 psi |
Overlap Shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Substrate Failure/Break/Yield |
975 psi |
Overlap Shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Substrate Failure/Break/Yield |
1,000 psi |
Overlap Shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Substrate Failure/Break/Yield |
550 psi |
Overlap Shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Cohesive Failure |
925 psi |
Overlap Shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Substrate Failure/Break/Yield |
50 psi |
Overlap Shear |
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Cohesive Failure |
250 psi |
|
|
|
|
|
|
Room Temperature |
Environmental & Chemical Exposure Test on HDPE, Cohesive Failure |