• Description for 3M F9752PC

    Utilize the 420 high performance adhesive system. This offers the ability to make adhesive bonds at temperature as low as 32°F (0°C). These products utilize a 58 lb. polycoated liner for moisture stability.

    *See Terms of Use Below

    Chemical Resistance Chemical Resistance: Very good
    Application Type Bond
    1 Part or 2 Part 1-Part
    Material Form Transfer tape
    Substrate Acrylic, Aluminum, Glass, Painted metal, Polycarbonate, Polypropylene, Steel, Stainless steel, L.D.Polyethylene, Epoxy, ABS
    Manufacturer 3M
    Chemistry Acrylic
    Cure Method Pressure Sensitive
    Application Temperature (°F) 70 to 100
    Color Clear
    High Temperature Resistance (°C) 149, 232
  • Technical Data for 3M F9752PC

    Overview
    • Chemical Resistance
      • Chemical Resistance : Relative Solvent Resistance - Very good
    • Application Type
    • 1 Part or 2 Part
      • 1-Part
    • Material Form
      • Tape - Transfer tape
    • Substrate
    • Chemistry
    • Application Method
      • Dispenser - Semi-automatic: S62C Pad Applicator, T646i and T646Wi application system, T653 Continuous Laminator
      • Contact
    • Cure Method
      • Pressure Sensitive (min) - Pressure Sensitive
    • Color
      • Clear / Transparent - Clear
    Specifications
    Cure Specs
    Application Temperature (°F) 70 to 100
    Bond Strength
    General Bond Strength (psi) 40 (oz./in.) Test Method
    Peel Strength (piw) 40 (oz./in), 45 (oz./in), 35 (oz./in), 50 (oz./in), 50 (oz./in), 45 (oz./in), 45 (oz./in), 25 (oz./in), 10 (oz./in), 15 (oz./in) Test Method
    Shear Strength (psi) 1000 (Grams), 500(Grams), 400 (Grams), 300 (Grams), 300 (Grams), 300 (Grams), 200 (Grams) Test Method
    Material Resistance
    UV Resistance Excellent
    High Temperature Resistance (°C) 149, 232
    Moisture/Humidity Resistance Moisture resistance
    Business Information
    Shelf Life Details 24 months from date of manufacture when stored in original cartons at 70°F (21°C) and 50% relative humidity.
    Shelf Life Temperature (°F) 70
    Shelf Life Type From date of manufacture.
    Shelf Life (mon) 24
  • Best Practices for 3M F9752PC

    *See Terms of Use Below

    1. Surface Preparation

      To obtain optimum adhesion, the bonding surfaces must be clean, dry and well unified. Typical surface cleaning solvents are isopropyl alcohol and water (rubbing alcohol) or heptane.

      Note: Be sure to follow the manufacturer's precautions and directions for use when using solvents.

    2. Application

      Bond strength is dependent upon the amount of adhesive-to-surface contact developed. Firm application pressure helps develop better adhesive contact and improve bond strength.

      Initial tape application to surfaces at temperatures below 50°F (10°C) is not recommended for most pressure sensitive adhesives because the adhesive becomes too firm to adhere readily. However, once properly applied, low temperature holding is generally satisfactory. 3MTM Adhesive Transfer Tapes F-9752PC and F-9755 PC can be bonded at temperatures as low as 32°F (0°C).

  • Comparable Materials for 3M F9752PC

    *See Terms of Use Below

    Spec Engine® Results

Popular Articles

Testing the effectiveness of surface treatments

Read Article

Plastic Bonding with Adhesives - Considerations Q&A

Read Article

What Projects Require Custom Adhesive Formulations and Why?

Read Article

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article

Featured Ads

Top Catalog Pages for 3M F9752PC

Gluespec Poll

When you're researching or sourcing materials online, what device are you using?
General Bond Strength Test Methods
General Bond Strength Substrate Test Method
40 (oz./in.) Steel ASTM D-3330
Peel Strength Test Methods
Peel Strength Type Substrate Test Time Test Temperature Test Method
40 (oz./in) 180° Peel Strength Stainless Steel 4,320 min 25°C ASTM D3330
45 (oz./in) 180° Peel Strength Painted Metal 4,320 min 25°C
35 (oz./in) 180° Peel Strength Glass 4,320 min 25°C
50 (oz./in) 180° Peel Strength Polycarbonate 4,320 min 25°C
50 (oz./in) 180° Peel Strength Acrylic 4,320 min 25°C
45 (oz./in) 180° Peel Strength Epoxy 4,320 min 25°C
45 (oz./in) 180° Peel Strength ABS 4,320 min 25°C
25 (oz./in) 180° Peel Strength Polypropylene 4,320 min 25°C
10 (oz./in) 180° Peel Strength LD. Polyethylene 4,320 min 25°C
15 (oz./in) 180° Peel Strength H.D. Polyethylene 4,320 min 25°C
Shear Strength Test Methods
Shear Strength Type Cure Time Substrate Test Time Test Temperature Test Method
1000 (Grams) Static shear strength 4,320 min Aluminum to a Stainless Steel 600,000 sec 22°C ASTM D3654, 1'' × 1'' Area Contact – Aluminum to a Stainless Steel – 72 Hr. dwell.
500(Grams) Static shear strength 4,320 min Aluminum to a Stainless Steel 600,000 sec 70°C ASTM D3654, 1'' × 1'' Area Contact – Aluminum to a Stainless Steel – 72 Hr. dwell.
400 (Grams) Static shear strength 4,320 min Aluminum to a Stainless Steel 600,000 sec 93°C ASTM D3654, 1'' × 1'' Area Contact – Aluminum to a Stainless Steel – 72 Hr. dwell.
300 (Grams) Static shear strength 4,320 min Aluminum to a Stainless Steel 600,000 sec 121°C ASTM D3654, 1'' × 1'' Area Contact – Aluminum to a Stainless Steel – 72 Hr. dwell.
300 (Grams) Static shear strength 4,320 min Aluminum to a Stainless Steel 600,000 sec 149°C ASTM D3654, 1'' × 1'' Area Contact – Aluminum to a Stainless Steel – 72 Hr. dwell.
300 (Grams) Static shear strength 4,320 min Aluminum to a Stainless Steel 600,000 sec 177°C ASTM D3654, 1'' × 1'' Area Contact – Aluminum to a Stainless Steel – 72 Hr. dwell.
200 (Grams) Static shear strength 4,320 min Aluminum to a Stainless Steel 600,000 sec 232°C ASTM D3654, 1'' × 1'' Area Contact – Aluminum to a Stainless Steel – 72 Hr. dwell.