Dow FC Parking Structure Sealant

Dow FC Parking Structure Sealant Datasheet
  • Description for Dow FC Parking Structure Sealant

    Good weatherability; resilient; long life reliability; unprimed adhesion; seals irregular surfaces; self-leveling; fast cure.

    *See Terms of Use Below

    Application Type Bond, Sealant
    1 Part or 2 Part 2 Part
    Material Form Liquid
    Manufacturer Dow
    Chemistry Silicone
    Cure Method Neutral-cure, Part A/Part B
    Cure Temperature (°C) 25
    Cure Time (min) Fast, 1,440 to 2,880, 2,880
    Viscosity (cPs) Self-leveling
    High Temperature Resistance (°C) 149
    Low Temperature Resistance (°C) -45

Questions about this material?

Dow - FC Parking Structure Sealant

Get personal assistance with your specific application needs.

Your Profile Edit

Popular Articles

Silicones in LED Lighting | Gluespec

Read Article

What Are the Differences Between Adhesives and Sealants?

Read Article

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

Testing the effectiveness of surface treatments

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article
Information provided by Gluespec

Why Register?

  • View Technical Details
  • View Test Methods
  • View Key Specifications
  • View Similar Materials
  • Save your Project Searches

Already registered? Sign in.

Questions? Learn more about Gluespec

Gluespec Poll

Which answer best describes a project you are currently working on?
Cure Temperature Test Methods
Cure Temperature Cure Time Test Method
25°C 50 percent RH
Cure Time Test Methods
Cure Time Test Method
Fast
1,440 to 2,880 min
2,880 min 50 percent RH
Work / Pot Time Test Methods
Work / Pot Time Temperature
<20 min 25°C
Tensile Strength Test Methods
Tensile Strength Cure Time Cure Temperature Cure Humidity Test Method
75 psi 2,880 min 25°C 50(%) RH ASTM D 412, After 48 hours at 25°C (77°F) and 50 percent RH
Elongation Test Methods
Elongation Test Method
1,600 % ASTM D 412, After 48 hours at 25°C (77°F) and 50 percent RH
>600 % ASTM C 1135, After 48 hours at 25°C (77°F) and 50 percent RH, Ultimate
Modulus Test Methods
Modulus Test Method
Ultra-low Modulus Test Method
23 psi ASTM D 412, at 150% elongation, After 48 hours at 25°C (77°F) and 50 percent RH
8 psi ASTM C 1135, at 25% elongation, After 48 hours at 25°C (77°F) and 50 percent RH
10 psi ASTM C 1135, at 50% elongation, After 48 hours at 25°C (77°F) and 50 percent RH
Shore OO Hardness Test Methods
Shore OO Hardness Shore Hardness Test Method Hardness Temperature
60 ASTM D 2240, After 48 hours at 25°C (77°F) and 50 percent RH 25°C