Dow FC Parking Structure Sealant Datasheet Dow FC Parking Structure Sealant

Information provided by Gluespec
  • Description for Dow FC Parking Structure Sealant

    Good weatherability; resilient; long life reliability; unprimed adhesion; seals irregular surfaces; self-leveling; fast cure.

    *See Terms of Use Below

    Application Type Bond, Sealant
    1 Part or 2 Part 2-Part
    Material Form Liquid
    Manufacturer Dow
    Chemistry Silicone
    Cure Method Neutral-cure, Part A/Part B
    Cure Temperature (°C) 25
    Cure Time (min) Fast, 1,440 to 2,880, 2,880
    Viscosity (cPs) Self-leveling
    High Temperature Resistance (°C) 149
    Low Temperature Resistance (°C) -45
  • Technical Data for Dow FC Parking Structure Sealant

    Overview
    • Application Type
    • 1 Part or 2 Part
      • 2-Part
    • Material Form
      • Liquid
    • Chemistry
    • Cure Method
      • 2-Part Cure - Part A/Part B
      • Other - Neutral-cure
    Specifications
    Cure Specs
    Cure Temperature (°C) 25 Test Method
    Cure Time (min) Fast, 1,440 to 2,880, 2,880 Test Method
    Viscosity (cPs) Self-leveling
    Work / Pot Time (min) <20 Test Method
    Bond Strength
    Tensile Strength (psi) 75 Test Method
    Material Resistance
    High Temperature Resistance (°C) 149
    Low Temperature Resistance (°C) -45
    Hardness
    Elongation (%) 1,600, >600 Test Method
    Shore OO Hardness 60 Test Method
    Flexibility Resilient
    Modulus (psi) Ultra-low, 23, 8, 10 Test Method
    Other Properties
    Flash Point (°F) 213.8
    Business Information
    Shelf Life Details When stored in the original, unopened container at or below 32°C (90°F) Dow Corning FC Parking Structure Sealant has a shelf life of 18 months from date of manufacture. Refer to product packaging for “Use By Date.” Keep containers tightly closed.
    Shelf Life Type From date of manufacture
    Shelf Life (mon) 18
  • Best Practices for Dow FC Parking Structure Sealant

    *See Terms of Use Below

    1. Surface Preparation

      Clean all concrete, masonry and stone joints of all contaminants and impurities. Porous substrates should be cleaned where necessary by grinding, saw cutting, blast cleaning (sand or water), mechanical abrading or a combination of these methods as required to provide a sound, clean, dry surface for sealant application. Dust, loose particles, etc., should be blown out of joints with dry, oil-free compressed air or be vacuum cleaned. Metal and glass surfaces adjacent to masonry should be cleaned by wiping with an oil-free absorbent cloth saturated with solvent such as xylene or toluene. Do not use alcohols as they inhibit the cure.

    2. Application

      When using Dow Corning FC Parking Structure Sealant with other Dow Corning® brand Parking Structure Sealants, please note that these materials are all compatible with one another in either the cured or uncured state, may come in contact with one another, and will bond to one another provided no debris or other contaminants interfere with the bond.

  • Comparable Materials for Dow FC Parking Structure Sealant

    *See Terms of Use Below

    Spec Engine® Results

Popular Articles

Silicones in LED Lighting | Gluespec

Read Article

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

Testing the effectiveness of surface treatments

Read Article

What Are the Differences Between Adhesives and Sealants?

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article

Featured Ads

Top Catalog Pages for Dow FC Parking Structure Sealant

Gluespec Poll

What level of expertise do you have in specialty chemicals like adhesives, sealants, conformal coatings, etc.?
Cure Temperature Test Methods
Cure Temperature Cure Time Test Method
25°C 50 percent RH
Cure Time Test Methods
Cure Time Test Method
Fast
1,440 to 2,880 min
2,880 min 50 percent RH
Work / Pot Time Test Methods
Work / Pot Time Temperature
<20 min 25°C
Tensile Strength Test Methods
Tensile Strength Cure Time Cure Temperature Cure Humidity Test Method
75 psi 2,880 min 25°C 50(%) RH ASTM D 412, After 48 hours at 25°C (77°F) and 50 percent RH
Elongation Test Methods
Elongation Test Method
1,600 % ASTM D 412, After 48 hours at 25°C (77°F) and 50 percent RH
>600 % ASTM C 1135, After 48 hours at 25°C (77°F) and 50 percent RH, Ultimate
Modulus Test Methods
Modulus Test Method
Ultra-low Modulus Test Method
23 psi ASTM D 412, at 150% elongation, After 48 hours at 25°C (77°F) and 50 percent RH
8 psi ASTM C 1135, at 25% elongation, After 48 hours at 25°C (77°F) and 50 percent RH
10 psi ASTM C 1135, at 50% elongation, After 48 hours at 25°C (77°F) and 50 percent RH
Shore OO Hardness Test Methods
Shore OO Hardness Shore Hardness Test Method Hardness Temperature
60 ASTM D 2240, After 48 hours at 25°C (77°F) and 50 percent RH 25°C