Description for Dow Sylgard 184 Silicone Elastomer
Two part; 10:1 mix; minimal shrinkage; no exotherm during cure; no solvents or cure byproducts; deep section cure; repairable; good dielectric properties; flexible elastomer.Brand Sylgard Chemical Resistance Good Application Type Adhesive, Pot , Encapsulate 1 Part or 2 Part 2 Part Material Form Liquid, Silicone elastomer Industry Relays, Solar cells, Sensors, Transformers, Connectors, Amplifiers, Smart Meters, High voltage resistor packs, E-Mobility Solutions, Smart Home Devices, Electronics, Lead integrated circuit Manufacturer Dow Chemistry Silicone, Solvent-free, Silicone elastomer Cure Method Base/Curing Agent, Heat, Room Temperature Cure Cure Temperature (°C) 20 to 25, 100, 125, 150 Viscosity (cPs) 3,500, Flowable Color Colorless Ozone Resistance Ozone resistance High Temperature Resistance (°C) 200 Low Temperature Resistance (°C) -45, -55 Light Refractive Index (RI) Good, 1.4118, 1.4225, 1.4028, 1.3997 Key Specifications Mil-Spec (United States Military Standard): I-81550C: MIL-I-81550C, Type II, QPL, UL (Underwriters Laboratory), ULC (Underwriters Laboratories of Canada), NFPA (National Fire Protection Association): UL 94: UL 94 V-1 -
Technical Data for Dow Sylgard 184 Silicone Elastomer
Overview
-
Chemical Resistance
- Chemical Resistance - Good
-
Application Type
- Adhesive
- Pottant / Encapsulant - Pot , Encapsulate
-
1 Part or 2 Part
- 1 Part or 2 Part - 2 Part
- Part A Name - Base
- Part B Name - Curing Agent
-
Material Form
- Elastomer - Silicone elastomer
- Liquid
-
Industry
- Smart Meters
- Smart Home Devices
- E-Mobility Solutions
- Electronics - Lead integrated circuit, Relays
- Solar Energy - Solar cells
- Sensors
- Transformers
- Connectors
- Amplifiers
- Voltage Resistors - High voltage resistor packs
- Power Supplies
- Industrial - Industrial controls
-
Chemistry
- Solvent-Free
- Silicone - Silicone elastomer
-
Application Method
- Dispenser - Automated mixing, Dispensing equipment, Manual mixing
-
Cure Method
- Room Temperature / Air Dry - Room Temperature Cure
- Heat
- 2-Part Cure - Base/Curing Agent
-
Color
- Clear / Transparent - Colorless
-
Key Specifications
- Mil-Spec (United States Military Standard): I-81550C: Type II, QPL - MIL-I-81550C, Type II, QPL
- UL (Underwriters Laboratory), ULC (Underwriters Laboratories of Canada), NFPA (National Fire Protection Association): UL 94: V-1 - UL 94 V-1
-
Brand
- Sylgard
Specifications
Cure Specs
Cure Temperature (°C) 20 to 25, 100, 125, 150 Test Method Viscosity (cPs) 3,500, Flowable Linear Shrinkage (%) Minimal shrinkage Mix Ratio 10:1 (by volume), 10:1 (by weight) Bond Strength
Tensile Strength (psi) 980 Material Resistance
Ozone Resistance Ozone resistance UV Resistance UV resistance Environmental Resistance Environmental resistance High Temperature Resistance (°C) 200 Low Temperature Resistance (°C) -45, -55 Moisture/Humidity Resistance Moisture/humidity resistance Conductivity
Dissipation Factor 0.00257, 0.00133 Test Method Dielectric Strength (V/mil) Good, Durable Dielectric Constant 2.72, 2.68 Test Method Thermal Conductivity (W/m°K) 0.27 Volume Resistivity (O) 2.9e14(ohms/cm) Hardness
Shore D Hardness 43 Test Method Flexibility Flexible Other Properties
Light Refractive Index (RI) Good, 1.4118, 1.4225, 1.4028, 1.3997 Test Method Specific Gravity 1.030 Coefficient of Thermal Expansion (CTE) 340 (Linear (micron/m °C or ppm )) Flash Point (°F) 213.8 Business Information
Shelf Life Details Shelf life is indicated by the “Use Before” date found on the product label. Refer to the product label for storage temperature requirements. Shelf Life Temperature (°F) 77 Shelf Life Type From date of manufacture Shelf Life (mon) 24 -
Popular Articles
Staking materials and properties
Read ArticleInfographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleTesting the effectiveness of surface treatments
Read ArticleSilicone Adhesives in the Food and Drug Industry
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Cure Temperature Test Methods
Cure Temperature | Cure Time Test Method |
---|---|
20 to 25°C | These data were collected on 50-100 gram samples of a lot believed to be typical and should be used as initial estimates of cure times. Times will vary slightly from batch to batch and can be longer or shorter due to thermal mass of your parts and your heating ramp rate. Pretesting is recommended to confrm adequate cure for your application, For primerless adhesion products, cure time is based on time to reach durometer. Full adhesion may take more time at the cure temperature. |
100°C | These data were collected on 50-100 gram samples of a lot believed to be typical and should be used as initial estimates of cure times. Times will vary slightly from batch to batch and can be longer or shorter due to thermal mass of your parts and your heating ramp rate. Pretesting is recommended to confrm adequate cure for your application, For primerless adhesion products, cure time is based on time to reach durometer. Full adhesion may take more time at the cure temperature. |
125°C | These data were collected on 50-100 gram samples of a lot believed to be typical and should be used as initial estimates of cure times. Times will vary slightly from batch to batch and can be longer or shorter due to thermal mass of your parts and your heating ramp rate. Pretesting is recommended to confrm adequate cure for your application, For primerless adhesion products, cure time is based on time to reach durometer. Full adhesion may take more time at the cure temperature. |
150°C | These data were collected on 50-100 gram samples of a lot believed to be typical and should be used as initial estimates of cure times. Times will vary slightly from batch to batch and can be longer or shorter due to thermal mass of your parts and your heating ramp rate. Pretesting is recommended to confrm adequate cure for your application, For primerless adhesion products, cure time is based on time to reach durometer. Full adhesion may take more time at the cure temperature. |
Cure Time Test Methods
Cure Time | Test Method |
---|
Work / Pot Time Test Methods
Work / Pot Time | Temperature |
---|
Dielectric Constant Test Methods
Dielectric Constant | Test Method |
---|---|
2.72 | Dielectric constant, 100 Hz |
2.68 | Dielectric constant, 100 KHz |
Dissipation Factor Test Methods
Dissipation Factor | Test Method |
---|---|
0.00257 | Dissipation factor, 100 Hz |
0.00133 | Dissipation factor, 100 KHz |
Shore D Hardness Test Methods
Shore D Hardness | Shore Hardness Test Method |
---|---|
43 | Durometer |
Light Refractive Index (RI) Test Methods
Light Refractive Index (RI) | Test Method |
---|---|
Good | |
1.4118 | @ 589 nm |
1.4225 | @ 632.8 nm |
1.4028 | @1321 nm |
1.3997 | @ 1554 nm |