Elantas (Altana) Easypoxy K-22 Datasheet Elantas (Altana) Easypoxy K-22

Information provided by Gluespec
  • Description for Elantas (Altana) Easypoxy K-22

    A black, two-component, 100%-solids, room temperature cure epoxy adhesive system. General-purpose adhesive and repair compound for metal, wood, rubber and most plastics.<br/>

    *See Terms of Use Below

    Brand Cytec, Easypoxy
    Application Type Bond, Repair, Seal
    1 Part or 2 Part 2-Part
    Material Form Paste
    Substrate Etched aluminum, Metal, Most plastics , Rubber, Wood, Aluminum
    Industry General purpose
    Manufacturer Elantas (Altana)
    Chemistry Solventless
    Application Method Spatula
    Cure Method Low heat cure, Room temperature cure
    Cure Temperature (°C) 20 to 25 Room temperature, 25, 65
    Cure Time (min) 1,440, 120
    Color Black, Clear
    Fungus Resistance Fungus Resistance
    Volume Resistivity (O) 4.0e13 (ohm-cm)
  • Technical Data for Elantas (Altana) Easypoxy K-22

    Overview
    • Application Type
    • 1 Part or 2 Part
      • 2-Part
    • Material Form
      • Paste
    • Substrate
    • Industry
    • Chemistry
    • Application Method
      • Brush - Stiff brush
      • Spatula/Trowel - Spatula
    • Cure Method
      • Room Temperature / Air Dry - Room temperature cure
      • Heat - Low heat cure
    • Color
      • Black
      • Clear / Transparent - Clear
    • Brand
      • Easypoxy
      • Cytec
    Specifications
    Cure Specs
    Cure Temperature (°C) 20 to 25 Room temperature, 25, 65
    Cure Time (min) 1,440, 120
    Linear Shrinkage (%) <1.00 Test Method
    Work / Pot Time (min) 30
    Mix Ratio 100:45 (by weight)
    Bond Strength
    General Bond Strength (psi) High
    Shear Strength (psi) 2,500, 1,600, 2,300 Test Method
    Compressive Strength (psi) 10,000 Test Method
    Flexural Strength (psi) 6,000 Test Method
    Tensile Strength (psi) 2,500, 1,600, 2,300, 3,000 Test Method
    Material Resistance
    Fungus Resistance Fungus Resistance
    Conductivity
    Dissipation Factor 0.01000 Test Method
    Dielectric Constant 4.60 Test Method
    Thermal Conductivity (W/m°K) 5.7 (cal/sec/cm2/°C/cm x 10-4) Test Method
    Volume Resistivity (O) 4.0e13 (ohm-cm) Test Method
    Hardness
    Shore D Hardness 85 Test Method
    Other Properties
    % Solids (%) 100
    Business Information
    Shelf Life Details Store between 20 - 30°C / 68 - 86°F in a dry controlled environment out of direct sunlight. This material should be suitable for use stored under these conditions in the original sealed containers for twelve (12) months from the date of shipment.
    Shelf Life Temperature (°F) 65 to 85
    Shelf Life Type From date of manufacture
    Shelf Life (mon) 12
  • Best Practices for Elantas (Altana) Easypoxy K-22

    *See Terms of Use Below

    1. Surface Preparation

      The repair surface must be dry and free from oil and dirt.

    2. Application

      Mix thoroughly with tongue depressor until color is uniform. The repair surface must be dry and free from oil and dirt. Apply with spatula or stiff brush. Apply to both joining surfaces, if possible, and wipe away excess material before it hardens.

      If resin has crystallized, place closed tube in a 49 – 71°C / 120 – 160°F water bath for 45 – 60 minutes.

    3. Clean-Up

      Clean equipment before the adhesive hardens

      a good hydrocarbon solvent is recommended.

  • Comparable Materials for Elantas (Altana) Easypoxy K-22

    *See Terms of Use Below

    Spec Engine® Results

Popular Articles

Testing the effectiveness of surface treatments

Read Article

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

What Are the Differences Between Adhesives and Sealants?

Read Article

Anaerobic Adhesives

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article

Featured Ads

Top Catalog Pages for Elantas (Altana) Easypoxy K-22

Gluespec Poll

Which answer best describes a project you are currently working on?
Linear Shrinkage Test Methods
Linear Shrinkage Test Method Temp
<1.00 % ASTM D2566 25°C
Compressive Strength Test Methods
Compressive Strength Test Temperature Test Method
10,000 psi 25°C ASTM D695
Flexural Strength Test Methods
Flexural Strength Test Temperature Test Method
6,000 psi 25°C ASTM D790
Tensile Strength Test Methods
Tensile Strength Substrate Test Temperature Test Method
2,500 psi Etched AL/AL 25°C
1,600 psi Etched AL/AL -55°C
2,300 psi Etched AL/AL 82°C
3,000 psi 25°C ASTM D412
Shear Strength Test Methods
Shear Strength Type Substrate Test Temperature Test Method
2,500 psi Lap Shear strength Etched aluminum /aluminum 25°C ASTM D1002
1,600 psi Lap Shear strength Etched aluminum /aluminum -55°C ASTM D1002
2,300 psi Lap Shear strength Etched aluminum /aluminum 82°C ASTM D1002
Dielectric Constant Test Methods
Dielectric Constant Temperature Test Method
4.60 25°C 1 kHz, ASTM D150
Dissipation Factor Test Methods
Dissipation Factor Temperature Test Method
0.01000 25°C 1 kHz, ASTM D150
Thermal Conductivity Test Methods
Thermal Conductivity Test Method
5.7 (cal/sec/cm2/°C/cm x 10-4)
Volume Resistivity Test Methods
Volume Resistivity Temp (°C) Test Method
4.0e13 (ohm-cm) 25°C ASTM D257
Shore D Hardness Test Methods
Shore D Hardness Shore Hardness Test Method Hardness Temperature
85 ASTM D2240 25°C