Description for Elantas (Altana) RN-1559
Liquid isocyanate terminated prepolymers that yield an elastomer with good tear and tensile strengths, good abrasion resistance, exceptional elongation, and good low temperature properties.Brand Cytec Application Type Bond 1 Part or 2 Part 2-Part Material Form Liquid Substrate Glass, Metal, Plastic Industry Gears, Industrial truck tires, Bushings Manufacturer Elantas (Altana) Chemistry isocyanate terminated prepolymers Cure Method 2 Parts Cure Temperature (°C) 100, 100 Cure Time (min) 480, 300 Viscosity (cPs) 25,000, 500 Color Light Amber -
Technical Data for Elantas (Altana) RN-1559
Overview
-
Application Type
- Adhesive - Bond
-
1 Part or 2 Part
- 2-Part
-
Material Form
- Liquid
-
Industry
- Trucks - Industrial truck tires
- Industrial
- Gears
- Bushing - Bushings
- Other - Rolls, Metal forming dies, Seals, Abrasion resistant belts, Casters, Impellers
-
Chemistry
- Other - isocyanate terminated prepolymers
-
Application Method
- Dispenser - automatic metering, mixing equipment
-
Cure Method
- 2-Part Cure - 2 Parts
-
Color
- Red - Light Amber
-
Brand
- Cytec
Specifications
Cure Specs
Cure Temperature (°C) 100, 100 Cure Time (min) 480, 300 Viscosity (cPs) 25,000, 500 Test Method Work / Pot Time (min) 2.00 to 8 Bond Strength
Tear Strength (piw) Good, 290 (pli), 400 (pli) Tensile Strength (psi) Good, 5,000, 800, 1,200, 4,000, 1,000, 1,500 Test Method Material Resistance
Abrasion Resistance good abrasion resistance Hardness
Shore A Hardness 70, 83, 90 Shore D Hardness 55, 30, 45 Elongation (%) Exceptional elongation, 700, 550 Other Properties
Specific Gravity 1.070 Test Method -
-
Best Practices for Elantas (Altana) RN-1559
-
Mixing
Pour mixed system into molds, preheated to 80-100°C that have been coated with CONAP® MR-5002 or equivalent, mold releases.
Automatic metering and mixing equipment can be used with these systems
-
Deairing/Degassing
Heat pre-weighed amounts of CONATHANE® prepolymer to 80-100°C and degas at 1-5 mm of vacuum for at least 5 minutes, or until excessive bubbling stops. Containers should be unlined metal, plastic, or glass, and should be large enough to allow for foaming during degassing.
When adding MbOCA to CONATHANE®, the MbOCA must be melted at 120°C prior to mixing. After adding curative, mix thoroughly and degas at 1-5 mm for 1 to 2 minutes.
-
-
Comparable Materials for Elantas (Altana) RN-1559
Spec Engine® Results
Popular Articles
Lightweighting drives automotive adhesives demand
Read Article6 objects held together by adhesives you probably can't live without
Read ArticleInfographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleTesting the effectiveness of surface treatments
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Viscosity Test Methods
Viscosity | Temperature |
---|---|
25,000 cPs | 25°C |
500 cPs | 100°C |
Tensile Strength Test Methods
Tensile Strength | Test Method |
---|---|
Good | |
5,000 psi | Die D |
800 psi | Die D,100% modulus |
1,200 psi | Die D,300% modulus |
4,000 psi | Die D |
1,000 psi | Die D,100% modulus |
1,500 psi | Die D,300% modulus |
Specific Gravity Test Methods
Specific Gravity | Temperature |
---|---|
1.070 | 25°C |