Elantas (Altana) UC-41

Elantas (Altana) UC-41 Datasheet
  • Description for Elantas (Altana) UC-41

    A two-component, unfilled urethane resin system that produces tough, impact resistant, dimensionally stable castings. UC-41 is used to produce prototype parts requiring a "thermoplastic" feel and appearance.

    *See Terms of Use Below

    Brand Cytec
    Application Type Bond
    1 Part or 2 Part 2 Part
    Material Form Liquid
    Manufacturer Elantas (Altana)
    Chemistry urethane
    Cure Method Part A/Part B
    Cure Temperature (°C) 25, 80, 25, 80
    Cure Time (min) 240, 60, 10,080, 960
    Viscosity (cPs) Low, 500
    Color Natural White
  • Technical Data for Elantas (Altana) UC-41

    Overview
    • Application Type
    • 1 Part or 2 Part
      • 1 Part or 2 Part - 2 Part
    • Material Form
      • Liquid
    • Industry
    • Chemistry
    • Application Method
      • Dispenser - processed by hand or by machine
    • Cure Method
      • 2-Part Cure - Part A/Part B
    • Color
      • White - Natural White
    • Brand
      • Cytec
    Specifications
    Cure Specs
    Cure Temperature (°C) 25, 80, 25, 80
    Cure Time (min) 240, 60, 10,080, 960
    Viscosity (cPs) Low, 500 Test Method
    Linear Shrinkage (%) Low, Not measurable (in/in), 0.0046 (in/in) Test Method
    Work / Pot Time (min) 4.00 Test Method
    Mix Ratio Convienient (by volume), 100:50 (by weight)
    Bond Strength
    Impact Strength (psi) 0.34 /2.3 (Ft.-lb/in.), 0.35 / 2.8 (Ft.-lb/in.) Test Method
    Flexural Strength (psi) 5,870, 7,870 Test Method
    Tensile Strength (psi) 5,500, 7,500 Test Method
    Material Resistance
    Impact Resistance High impact resistance
    Conductivity
    Unfilled Unfilled
    Dissipation Factor 0.00500 Test Method
    Dielectric Strength (V/mil) 581 (vpm) Test Method
    Dielectric Constant 3.80 Test Method
    Volume Resistivity (O) 1.2e14 (ohm/cm) Test Method
    Hardness
    Shore D Hardness 80, High, Excellent machinability Test Method
    Elongation (%) 6, 7 Test Method
    Modulus (psi) 174,155, 207,804 Test Method
    Other Properties
    Glass Transition Temp (Tg) (°C) 63, 93 Test Method
    Specific Gravity 1.100 Test Method
    Business Information
    Shelf Life Details Both Part A and Part B components are moisture sensitive. Avoid the use of paper cups and wooden sticks. Unless the contents are used within one day, we recommend flushing with dry nitrogen or CONAP® Dri-Purge each time the containers are closed., CONATHANE® UC-41, Part A and Part B, have a shelf life of 18 months from date of manufacture when stored in their original, unopened containers at 65°-85°F.
    Shelf Life Temperature (°F) 149 to 185
    Shelf Life Type From date of manufacture
    Shelf Life (mon) 12, 18
  • Best Practices for Elantas (Altana) UC-41

    *See Terms of Use Below

    1. Application

      CONATHANE® UC-41 may be processed by hand or by machine.

      CONATHANE® UC-41 has very good adhesion to most substrates and generally will not require the use of a primer. If adhesion improvement is necessary, contact Cytec Industries Inc. for specific recommendations. If the cast part is to be demolded after cure, apply a CONAP® mold release agent prior to casting. Castings can generally be demolded in 4 hours at room temperature

    2. Mixing

      Mix the two components thoroughly at 25°C in the recommended mix ratio. Stir carefully to prevent entrapment of air.

    3. Deairing/Degassing

      If stirring is done carefully degassing of the mixed material may not be necessary. If air entrapment is excessive, degas the mixture for 1 to 1 2 minutes at 1-5 mm of vacuum.

  • Comparable Materials for Elantas (Altana) UC-41

    *See Terms of Use Below

    Spec Engine® Results

Questions about this material?

Elantas (Altana) - UC-41

Get personal assistance with your specific application needs.

Your Profile Edit

Popular Articles

Testing the effectiveness of surface treatments

Read Article

Characteristics of MMAs

Read Article

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

An Overview of Fluid Dispensing Systems & How They’re Used

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article
Information provided by Gluespec

Why Register?

  • View Technical Details
  • View Test Methods
  • View Key Specifications
  • View Similar Materials
  • Save your Project Searches

Already registered? Sign in.

Questions? Learn more about Gluespec

Gluespec Poll

Who do you read or follow for engineering news and entertainment?
Linear Shrinkage Test Methods
Linear Shrinkage Test Method Temp
Low
Not measurable (in/in) Cytec, Cured @ RT 25°C
0.0046 (in/in) Cytec, Cured 16 hours @ 80 [C] 80°C
Viscosity Test Methods
Viscosity Temperature
Low
500 cPs 25°C
Work / Pot Time Test Methods
Work / Pot Time Test Method Temperature
4.00 min (200 grams) 25°C
Flexural Strength Test Methods
Flexural Strength Cure Time Cure Temperature Test Method
5,870 psi 25°C ASTM D790
7,870 psi 960 min 80°C ASTM D790
Impact Strength Test Methods
Impact Strength Cure Temperature Test Method
0.34 /2.3 (Ft.-lb/in.) 25°C Izod, ASTM D-256, Notched / Unotched
0.35 / 2.8 (Ft.-lb/in.) 80°C Izod, ASTM D-256, Notched / Unotched
Tensile Strength Test Methods
Tensile Strength Cure Time Cure Temperature Test Method
5,500 psi 25°C ASTM D638
7,500 psi 960 min 80°C ASTM D638
Dielectric Constant Test Methods
Dielectric Constant Temperature Test Method
3.80 25°C ASTM D150, Dielectric Constant @ 25°C @ 1 KHz
Dielectric Strength Test Methods
Dielectric Strength Test Method
581 (vpm) ASTM D149, (1/16" thick)
Dissipation Factor Test Methods
Dissipation Factor Temperature Test Method
0.00500 25°C ASTM D150, Dissipation Factor @ 25°C @ 1 KHz
Volume Resistivity Test Methods
Volume Resistivity Temp (°C) Test Method
1.2e14 (ohm/cm) 25°C ASTM D257
Elongation Test Methods
Elongation Test Method
6 % ASTM D638, (Cured @ Room Temperature)
7 % ASTM D638, (Cured 1 hour @ RT + 16 Hrs. @ 80ºC)
Modulus Test Methods
Modulus Temperature Test Method
174,155 psi 25°C Cured @ Room Temperature, ASTM D790
207,804 psi 80°C Cured 16 hours @ 80°C, ASTM D790
Shore D Hardness Test Methods
Shore D Hardness Shore Hardness Test Method
80 ASTM D2240
High
Excellent machinability
Glass Transition Temp (Tg) Test Methods
Glass Transition Temp (Tg) Glass Transition Temperature (Tg) Test Method
63°C Cured @ Room Temperature
93°C Cured 16 hours @ 80°C
Specific Gravity Test Methods
Specific Gravity Test Method
1.100 ASTM D792
;