Description for Elantas (Altana) UC-48
A liquid, two-component, unfilled polyurethane resin that produces tough, high-impact resistant, dimensionally stable castings. It is used to produce prototype parts requiring a “thermoplastic” feel and appearance.Note: This material has been discontinued. Please view the Comparable Materials tab or call us at (262) 293-7970 for additional help.
Brand Cytec Application Type Bond, stable casting 1 Part or 2 Part 2-Part Material Form Liquid Manufacturer Elantas (Altana) Chemistry unfilled polyurethane resin Cure Method Part A/Part B Cure Temperature (°C) 20 to 25, 60, 20 to 25, 60, 20 to 25, 60 Cure Time (min) 75, 25, 960, 960, 10,080, 10,080 Viscosity (cPs) Low, 400, 250 Color Opaque, White -
Technical Data for Elantas (Altana) UC-48
Overview
-
Application Type
- Casting / Moldmaking - stable casting
- Adhesive - Bond
-
1 Part or 2 Part
- 2-Part
-
Material Form
- Liquid
-
Industry
- Industrial
- Other - used to produce prototype parts requiring a “thermoplastic” feel and appearance.
-
Chemistry
- Polyurethane - unfilled polyurethane resin
-
Cure Method
- 2-Part Cure - Part A/Part B
-
Color
- White
- Other - Opaque
-
Brand
- Cytec
Specifications
Cure Specs
Cure Temperature (°C) 20 to 25, 60, 20 to 25, 60, 20 to 25, 60 Test Method Cure Time (min) 75, 25, 960, 960, 10,080, 10,080 Test Method Viscosity (cPs) Low, 400, 250 Test Method Linear Shrinkage (%) Low, 0.0012 (in./in.), 0.011 (in./in.) Test Method Work / Pot Time (min) 13, 9 Test Method Mix Ratio Convenient (by volume), 100:120 (by volume), 100:100 (by weight) Bond Strength
Impact Strength (psi) 0.55/2.80 (ft.lb./in.), 0.49/2.70 (ft.lb./in.) Test Method Flexural Strength (psi) 6,600, 7,000 Test Method Tear Strength (piw) 365 (pli), 400 (pli) Test Method Tensile Strength (psi) 4,600, 5,100 Test Method Material Resistance
Impact Resistance high-impact resistant Conductivity
Filler Unfilled Hardness
Shore D Hardness 72, 72, unique ability to retain its hardness at elevated temperatures Test Method Elongation (%) 5, 5 Test Method Flexibility Curing flexibility Modulus (psi) 162,000, 175,000 Test Method Other Properties
Specific Gravity 1.060, 1.060 Test Method Business Information
Shelf Life Details Both the Part A and Part B components of CONATHANE® UC-48 are moisture sensitive. Avoid the use of paper cups and wooden sticks. Unless the contents are used within one day, we recommend flushing containers with dry nitrogen or CONAP® Dri-Purge each time the are closed.;CONATHANE® UC-48 Part A and Part B have a shelf life of 15 months from date of manufacture when stored in their original, unopened containers at 65°-85°F. Shelf Life Temperature (°F) 149 to 185 Shelf Life Type From date of manufacture Shelf Life (mon) 15 -
-
Best Practices for Elantas (Altana) UC-48
-
Mixing
Thoroughly mix the two components together at the recommended ratio. Stir carefully at 25°C to prevent entrapment of air. If air entrapment is excessive, degas the mixture for 2-3 minutes at 1-5 mm of vacuum. If mixing and stirring is done carefully, degassing of the mixed material may not be necessary.
-
-
Comparable Materials for Elantas (Altana) UC-48
Spec Engine® Results
Popular Articles
An Overview of Fluid Dispensing Systems & How They’re Used
Read ArticleCharacteristics of MMAs
Read ArticleTesting the effectiveness of surface treatments
Read ArticleInfographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Cure Temperature Test Methods
Cure Temperature | Cure Time Test Method |
---|---|
20 to 25°C | Demold time |
60°C | Demold time |
20 to 25°C | Post cure |
60°C | Post Cure |
20 to 25°C | Alternate Post Cure |
60°C | Alternate Post Cure |
Cure Time Test Methods
Cure Time | Test Method |
---|---|
75 min | Demold time |
25 min | Demold time |
960 min | Post cure |
960 min | Post Cure |
10,080 min | Alternate Post Cure |
10,080 min | Alternate Post Cure |
Linear Shrinkage Test Methods
Linear Shrinkage | Test Method | Temp |
---|---|---|
Low | ||
0.0012 (in./in.) | ASTM D2566 | RT |
0.011 (in./in.) | ASTM D2566 | 60°C |
Viscosity Test Methods
Viscosity | Temperature |
---|---|
Low | |
400 cPs | RT |
250 cPs | 60°C |
Work / Pot Time Test Methods
Work / Pot Time | Temperature |
---|---|
13 min | RT |
9 min | 60°C |
Flexural Strength Test Methods
Flexural Strength | Cure Temperature | Test Method |
---|---|---|
6,600 psi | 25°C | ASTM D790 |
7,000 psi | 60°C | ASTM D790 |
Impact Strength Test Methods
Impact Strength | Cure Temperature | Test Method |
---|---|---|
0.55/2.80 (ft.lb./in.) | 25°C | ASATM D256, Notched/Unnotched |
0.49/2.70 (ft.lb./in.) | 60°C | ASATM D256, Notched/Unnotched |
Tear Strength Test Methods
Tear Strength | Cure Temperature | Test Method |
---|---|---|
365 (pli) | 25°C | ASTM D624, Die C |
400 (pli) | 60°C | ASTM D624, Die C |
Tensile Strength Test Methods
Tensile Strength | Cure Temperature | Test Method |
---|---|---|
4,600 psi | Room Temperature | ASTM D412 |
5,100 psi | 60°C | ASTM D412 |
Elongation Test Methods
Elongation | Test Method |
---|---|
5 % | ASTM D412, at (RT) |
5 % | ASTM D412, at 60 [C] |
Modulus Test Methods
Modulus | Test Method |
---|---|
162,000 psi | ASTM D790 |
175,000 psi | ASTM D790 |
Shore D Hardness Test Methods
Shore D Hardness | Shore Hardness Test Method |
---|---|
72 | ASTM D2240,at RT |
72 | ASTM D2240, at 60 [C] |
unique ability to retain its hardness at elevated temperatures |
Specific Gravity Test Methods
Specific Gravity | Temperature | Test Method |
---|---|---|
1.060 | 25°C | ASTM D792, @ 25 (C) |
1.060 | 60°C | ASTM D792, @ 25 © |