Description for Epoxy Technology Epo-Tek 301-2FL
• Two component • Optical and semiconductor grade • Epoxy resin • Suitable for LED encapsulation • Resist<br/>yellowing over 17 days of continuous UV light exposure • Resistant to impact • Resistant to vibrations • Underfill for flip chips.<br/>Brand Epo-Tek Application Type Bond, Casting, Encapsulation, Potting 1 Part or 2 Part 2-Part Material Form Liquid Substrate Glass, Metals, Most Plastics, Wood, Porous objects, Wooden objects Industry Suitable for LED encapsulation, Underfill for flip chips, Semiconductor grade, Optical grade, Underfill for flip chips, Glob top encapsulation over wire bonds, Spin coating at wafer level, LCD optical lamination, Bonding optics inside OEM / scientific instruments, Fiber optic, Mounting optics inside fiber components, Terminating fiber into ferrule, Bundling fibers, Spectral transmission of visible and IR light, Sealing of glass plates Manufacturer Epoxy Technology Chemistry Epoxy resin Cure Method 2-part cure, Heat cure, Room temperature cure Cure Temperature (°C) 80, >23 Cure Time (min) 180, >4,320 Viscosity (cPs) Pourable, 100 to 200 Non-Yellowing UV Resistance: Resist yellowing over 17 days of continuous UV light exposure High Temperature Resistance (°C) <250, 325 Volume Resistivity (O) >= 0.6e12 (Ohm-cm) Stress Relief Low Stress Light Refractive Index (RI) 1.5102 -
Technical Data for Epoxy Technology Epo-Tek 301-2FL
Overview
-
Application Type
- Casting / Moldmaking - Casting
- Adhesive - Bond
- Pottant / Encapsulant - Potting, Encapsulation
-
1 Part or 2 Part
- 2-Part
-
Material Form
- Liquid
-
Industry
- Semiconductor - Semiconductor grade
- Optical - Optical grade, LCD optical lamination, Fiber optic, Bonding optics inside OEM / scientific instruments, Mounting optics inside fiber components, Terminating fiber into ferrule, Bundling fibers, Spectral transmission of visible and IR light, Sealing of glass plates
- LED (Light-Emitting Diodes) - Suitable for LED encapsulation
- Wafer - Spin coating at wafer level
- Flip chip - Underfill for flip chips
- Underfill - Underfill for flip chips
- Glob Top - Glob top encapsulation over wire bonds
- Other - Bonding glass cover slip over V-groove
-
Chemistry
- Epoxy - Epoxy resin
-
Cure Method
- Room Temperature / Air Dry - Room temperature cure
- Heat - Heat cure
- 2-Part Cure
-
Brand
- Epo-Tek
Specifications
Cure Specs
Cure Temperature (°C) 80, >23 Test Method Cure Time (min) 180, >4,320 Test Method Viscosity (cPs) Pourable, 100 to 200 Test Method Work / Pot Time (min) 600 Test Method Thixotropic Thixotropic Mix Ratio 100:35 (by weight) Bond Strength
General Bond Strength (psi) Very good Shear Strength (psi) >2,000, 3,556 Test Method Material Resistance
High Temperature Resistance (°C) <250, 325 Test Method Impact Resistance Resistant to impact Vibration Resistance/Shock Resistance Resistant to vibrations Conductivity
Dissipation Factor Test Method Dielectric Constant 3.54 Test Method Volume Resistivity (O) >= 0.6e12 (Ohm-cm) Test Method Hardness
Stress Relief Low Stress Shore D Hardness 70 Test Method Flexibility Flexible Modulus (psi) 318,685 Test Method Other Properties
Glass Transition Temp (Tg) (°C) >45 Test Method Light Refractive Index (RI) 1.5102 Test Method Outgassing 0.50%, 0.96%, 3.52% Test Method Coefficient of Thermal Expansion (CTE) 56e-6 (in/in°C), 211e-6 (in/in°C) Test Method Business Information
Shelf Life Temperature (°F) 68 to 77 Room temperature, -40 Shelf Life (mon) 12 Bulk, 6 Syringe -
-
Best Practices for Epoxy Technology Epo-Tek 301-2FL
-
Comparable Materials for Epoxy Technology Epo-Tek 301-2FL
Spec Engine® Results
Closest Results from this Manufacturer
Popular Articles
Testing the effectiveness of surface treatments
Read ArticleElectrically Conductive Adhesives
Read ArticleEpoxy Adhesives for Medical Devices
Read ArticleInfographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Cure Temperature Test Methods
Cure Temperature | Cure Time Test Method |
---|---|
80°C | Recommended cure |
>23°C | Minimum alternative cure |
Cure Time Test Methods
Cure Time | Test Method |
---|---|
180 min | Recommended cure |
>4,320 min | Minimum alternative cure |
Viscosity Test Methods
Viscosity | Test Method | Temperature |
---|---|---|
Pourable | Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification.; Test on lot acceptance basis | |
100 to 200 cPs | @ 100 rpm; Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification.; Test on lot acceptance basis | 23°C |
Work / Pot Time Test Methods
Work / Pot Time | Test Method |
---|---|
600 min | Pot life |
Shear Strength Test Methods
Shear Strength | Type | Cure Temperature | Test Method |
---|---|---|---|
>2,000 psi | Lap shear | 23°C | Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification. |
3,556 psi | Die shear | 23°C | Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification.; Test on lot acceptance basis. |
High Temperature Resistance Test Methods
High Temperature Resistance | Test Method |
---|---|
<250°C | Intermittent; Suggested operating temperature; Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification.; Test on lot acceptance basis. |
325°C | Degradation temperature; Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification. |
Dielectric Constant Test Methods
Dielectric Constant | Test Method |
---|---|
3.54 | 1KHz; Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification.; Test on lot acceptance basis. |
Dissipation Factor Test Methods
Dissipation Factor | Test Method |
---|
Volume Resistivity Test Methods
Volume Resistivity | Temp (°C) | Test Method |
---|---|---|
>= 0.6e12 (Ohm-cm) | 23°C | Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification.; Test on lot acceptance basis. |
Modulus Test Methods
Modulus | Test Method |
---|---|
318,685 psi | Storage modulus; Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification. |
Shore D Hardness Test Methods
Shore D Hardness | Shore Hardness Test Method |
---|---|
70 | Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification.; Test on lot acceptance basis. |
Coefficient of Thermal Expansion (CTE) Test Methods
Coefficient of Thermal Expansion (CTE) | CTE Test Method |
---|---|
56e-6 (in/in°C) | Below Tg; Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification.; Test on lot acceptance basis. |
211e-6 (in/in°C) | Above Tg; Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification.; Test on lot acceptance basis. |
Glass Transition Temp (Tg) Test Methods
Glass Transition Temp (Tg) | Glass Transition Temperature (Tg) Test Method |
---|---|
>45°C | Dynamic cure: 20-200°C/ISO 25 Min; Ramp -10-200°C @20°C/Min; Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification.; Test on lot acceptance basis. |
Light Refractive Index (RI) Test Methods
Light Refractive Index (RI) | Temperature | Test Method |
---|---|---|
1.5102 | 23°C | @ 589 nm; Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification.; Test on lot acceptance basis. |
Outgassing Test Methods
Outgassing | Temperature (°C) | Test Method |
---|---|---|
0.50% | 200°C | Weight loss; Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification.; Test on lot acceptance basis. |
0.96% | 250°C | Weight loss; Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification.; Test on lot acceptance basis. |
3.52% | 300°C | Weight loss; Cure condition: 80°C / 3 Hours; Different batches, conditions & applications yield differing results.; Data is not guaranteed.; To be used as a guide only, not as a specification.; Test on lot acceptance basis. |