Henkel Armstrong A-297 Datasheet Henkel Armstrong A-297

Information provided by Gluespec
  • Description for Henkel Armstrong A-297

    Offer long working life combined with fast-elevated temperature cures required by many of today’s high-speed production lines.

    Note: This material has been discontinued. Please view the Comparable Materials tab or call us at (262) 293-7970 for additional help.

    *See Terms of Use Below

    Brand Armstrong
    Application Type Adhesive
    1 Part or 2 Part 2-Part
    Material Form Liquid, Paste
    Substrate Al, ceramics, Metal, plastics
    Manufacturer Henkel
    Chemistry Epoxy
    Cure Method 2 Parts
    Cure Temperature (°C) 149
    Cure Time (min) 30
    Viscosity (cPs) Paste
  • Technical Data for Henkel Armstrong A-297

    Overview
    • Application Type
    • 1 Part or 2 Part
      • 2-Part
    • Material Form
      • Liquid
      • Paste
    • Substrate
    • Chemistry
    • Cure Method
      • 2-Part Cure - 2 Parts
    • Brand
      • Armstrong
    Specifications
    Cure Specs
    Cure Temperature (°C) 149
    Cure Time (min) 30
    Viscosity (cPs) Paste
    Work / Pot Time (min) Long Test Method
    Thixotropic Thixotropic
    Mix Ratio 3:2 (by volume), 3:2 (by weight)
    Bond Strength
    General Bond Strength (psi) 1,500, 1,000
    Cleavage Strength (psi) 800, 500
    Tensile Strength (psi) 3,000, 3,000, 700, 500, 2,800, 2,500, 1,000, 1,500 Test Method
    Hardness
    Elongation (%) 10
    Other Properties
    Specific Gravity 1.200 to 1.260, 1.020 to 1.080, 1.160, 1.100 Test Method
    Business Information
    Shelf Life Details Store below 25°C out of sunlight and in original unopened containers., Refer to packaging specific quote for shelf life information.
    Shelf Life Temperature (°F) <77
  • Best Practices for Henkel Armstrong A-297

    *See Terms of Use Below

    1. Surface Preparation

      Surface to be bonded should be clean and dry. For critical applications refer to Bulletin No. 964

    2. Application

      Apply the adhesive to surfaces to be bonded (preferably both surfaces) and press together.

    3. Mixing

      Thoroughly mix the Part B with the Part A in a clean, discardable container, using correct mix ratio. Avoid introduction of excess air.

    4. Curing

      Light clamping may be used to keep parts in position during cure.

      Cure as desired

  • Comparable Materials for Henkel Armstrong A-297

    *See Terms of Use Below

    Spec Engine® Results

Popular Articles

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

Testing the effectiveness of surface treatments

Read Article

Electrically Conductive Adhesives

Read Article

Epoxy Adhesives for Medical Devices

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article

Featured Ads

Top Catalog Pages for Henkel Armstrong A-297

Gluespec Poll

Which answer best describes a project you are currently working on?
Work / Pot Time Test Methods
Work / Pot Time Test Method Temperature
Long
Tensile Strength Test Methods
Tensile Strength Cure Time Cure Temperature Substrate Test Temperature Test Method
3,000 psi 30 min 149°C al/al 25°C CURED SYSTEM A-297, Cured 30 minutes @ 300°F
3,000 psi 30 min 149°C al/al 25°C CURED SYSTEM A-297, Cured 30 minutes @ 300°F
700 psi 30 min 149°C al/al 82°C CURED SYSTEM A-297, Cured 30 minutes @ 300°F
500 psi 30 min 149°C al/al 82°C CURED SYSTEM A-297, Cured 30 minutes @ 300°F
2,800 psi 30 min 149°C al/al -51°C CURED SYSTEM A-297, Cured 30 minutes @ 300°F
2,500 psi 30 min 149°C al/al -51°C CURED SYSTEM A-297, Cured 30 minutes @ 300°F
1,000 psi 30 min 149°C CURED SYSTEM A-297, Cured 30 minutes @ 300°F
1,500 psi 30 min 149°C CURED SYSTEM A-297, Cured 30 minutes @ 300°F
Specific Gravity Test Methods
Specific Gravity Test Method
1.200 to 1.260 A-297 "A"
1.020 to 1.080 A-297 "B"
1.160 A-297, CURED SYSTEM
1.100 A-297, CURED SYSTEM