Henkel Armstrong X-81 Activator A Datasheet Henkel Armstrong X-81 Activator A

Information provided by Gluespec
  • Description for Henkel Armstrong X-81 Activator A

    A fast-setting compound that is thixotropic in nature. The systems has three components. The mixed material is dark amber in appearance.

    *See Terms of Use Below

    Brand Armstrong
    Application Type Bond, Encapsulate, Repair
    1 Part or 2 Part Three components
    Material Form Paste
    Substrate Al
    Industry Rigid Electrical components, Printed circuit boards
    Manufacturer Henkel
    Chemistry Epoxy
    Cure Method Base resin/Flexible Resin #1/Activator A
    Cure Temperature (°C) 25, 74
    Cure Time (min) 1,440, 60 to 120
    Viscosity (cPs) 20,000 to 180,000, 5.00 to 15, 500 to 1,500

Popular Articles

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

Testing the effectiveness of surface treatments

Read Article

Epoxies in the Medical Device Industry

Read Article

Electrically Conductive Adhesives

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article

Featured Ads

Gluespec Poll

Who do you read or follow for engineering news and entertainment?
Shear Strength Test Methods
Shear Strength Type Cure Time Cure Temperature Substrate Test Method
>1,200 psi Tensile shear strength 120 min 74°C al/al X-81 & Act “A” 100/10, Cured 2 hrs 165°F
>1,000 psi Tensile shear strength 4,320 min 25°C al/al X-81 & Act “A” 100/10, Cured 3 days 77°F
>3,000 psi Tensile shear strength 120 min 74°C al/al X-81, Act A, & Flex Resin #1 100/10/20, Cured 2 hrs 165°F
>1,800 psi Tensile shear strength 4,320 min 25°C al/al X-81, Act A, & Flex Resin #1 100/10/20, Cured 3 days 77°F
Coefficient of Thermal Expansion (CTE) Test Methods
Coefficient of Thermal Expansion (CTE) CTE Test Method
3.2 x 10(-5) (in/in°F) X-81 & Act “A” 100/10
4.3 x 10(-5) (in/in°F) X-81, Act A, & Flex Resin #1 100/10/20
Specific Gravity Test Methods
Specific Gravity Test Method
1.200 X-81 & Act “A” 100/10