• Description for Henkel ETP 352

    • Two-Part • General Purpose • Adjustable Flexibility • Clear Epoxy Adhesive • Wide Range of Product Assembly Applications • Bonding Dissimilar Substrates • Assemblies Requiring a Clear Adhesive • Room Temperature Curable, Accelerated by Heat • Easy to Use and Apply • Easy Mix Ratio • Adjustable Hardness and Flexibility • Adhesion to a Wide Variety of Substrates •<br/>

    *See Terms of Use Below

    Brand Bondmaster
    Application Type Bond
    1 Part or 2 Part 2 Part
    Material Form Liquid
    Substrate Metals, Neoprene, Plastics, Nitrile Rubber, Aluminum
    Manufacturer Henkel
    Chemistry Epoxy, Amine
    Cure Method Part A/Part B
    Cure Temperature (°C) 20 to 25 Room Temperature, 25, 45, 65, 105
    Cure Time (min) 960 to 1,440, 240 to 360, 120 to 240, 15 to 30
    Viscosity (cPs) 20,000, 20,000, 21,000
    Color Clear
    High Temperature Resistance (°C) 90, 80, 65
    Low Temperature Resistance (°C) -40, -55, -55
    Density (g/cm³) 1.060, 1.030, 1.010

Popular Articles

Epoxies in the Medical Device Industry

Read Article

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

Testing the effectiveness of surface treatments

Read Article

Electrically Conductive Adhesives

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article

Featured Ads

Gluespec Poll

What level of expertise do you have in specialty chemicals like adhesives, sealants, conformal coatings, etc.?
Viscosity Test Methods
Viscosity Test Method Temperature
20,000 cPs Brookfield Viscosity, at 25°C 77°F,Rigid 25°C
20,000 cPs Brookfield Viscosity, at 25°C (77°F), Semi Rigid 25°C
21,000 cPs Brookfield Viscosity, at 25°C (77°F), Flexible 25°C
Work / Pot Time Test Methods
Work / Pot Time Test Method
120 min Rigid
140 min Semi-Rigid
160 min Flexible
Shear Strength Test Methods
Shear Strength Type Substrate Test Temperature Test Method
2,400 psi Lap shear strength Al to Al 25°C ASTM D-1002, Rigid
Dielectric Constant Test Methods
Dielectric Constant Test Method
3.00 Dielectric constant, 1 MHz, ASTM D-1550
Dielectric Strength Test Methods
Dielectric Strength Test Method
400 V/mil ASTM D-150
Dissipation Factor Test Methods
Dissipation Factor Test Method
0.03000 Dissipation factor, 1 MHz, ASTM D-257
Shore A Hardness Test Methods
Shore A Hardness Shore Hardness Test Method
45 Hardness/Durometer Test Method
Adjustable ASTM D-2240
Shore D Hardness Test Methods
Shore D Hardness Shore Hardness Test Method
75 Hardness/Durometer Test Method
52 ASTM D-2240
Adjustable ASTM D-2240