Description for Henkel ETP 352
• Two-Part • General Purpose • Adjustable Flexibility • Clear Epoxy Adhesive • Wide Range of Product Assembly Applications • Bonding Dissimilar Substrates • Assemblies Requiring a Clear Adhesive • Room Temperature Curable, Accelerated by Heat • Easy to Use and Apply • Easy Mix Ratio • Adjustable Hardness and Flexibility • Adhesion to a Wide Variety of Substrates •<br/>Brand Bondmaster Application Type Bond 1 Part or 2 Part 2 Part Material Form Liquid Substrate Metals, Neoprene, Plastics, Nitrile Rubber, Aluminum Manufacturer Henkel Chemistry Epoxy, Amine Cure Method Part A/Part B Cure Temperature (°C) 20 to 25 Room Temperature, 25, 45, 65, 105 Cure Time (min) 960 to 1,440, 240 to 360, 120 to 240, 15 to 30 Viscosity (cPs) 20,000, 20,000, 21,000 Color Clear High Temperature Resistance (°C) 90, 80, 65 Low Temperature Resistance (°C) -40, -55, -55 Density (g/cm³) 1.060, 1.030, 1.010
Popular Articles
Epoxies in the Medical Device Industry
Read ArticleInfographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleTesting the effectiveness of surface treatments
Read ArticleElectrically Conductive Adhesives
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Viscosity Test Methods
Viscosity | Test Method | Temperature |
---|---|---|
20,000 cPs | Brookfield Viscosity, at 25°C 77°F,Rigid | 25°C |
20,000 cPs | Brookfield Viscosity, at 25°C (77°F), Semi Rigid | 25°C |
21,000 cPs | Brookfield Viscosity, at 25°C (77°F), Flexible | 25°C |
Work / Pot Time Test Methods
Work / Pot Time | Test Method |
---|---|
120 min | Rigid |
140 min | Semi-Rigid |
160 min | Flexible |
Shear Strength Test Methods
Shear Strength | Type | Substrate | Test Temperature | Test Method |
---|---|---|---|---|
2,400 psi | Lap shear strength | Al to Al | 25°C | ASTM D-1002, Rigid |
Dielectric Constant Test Methods
Dielectric Constant | Test Method |
---|---|
3.00 | Dielectric constant, 1 MHz, ASTM D-1550 |
Dielectric Strength Test Methods
Dielectric Strength | Test Method |
---|---|
400 V/mil | ASTM D-150 |
Dissipation Factor Test Methods
Dissipation Factor | Test Method |
---|---|
0.03000 | Dissipation factor, 1 MHz, ASTM D-257 |
Shore A Hardness Test Methods
Shore A Hardness | Shore Hardness Test Method |
---|---|
45 | Hardness/Durometer Test Method |
Adjustable | ASTM D-2240 |
Shore D Hardness Test Methods
Shore D Hardness | Shore Hardness Test Method |
---|---|
75 | Hardness/Durometer Test Method |
52 | ASTM D-2240 |