A two-part, smooth, brushable, non-sag, room temperature curing adhesive that produces bonds with excellent shear strength. Easy to apply paste that cures to handling strength overnight at room temperature.Brand Armstrong Application Type Bond 1 Part or 2 Part 2-Part Material Form Paste Substrate Ceramic, Aluminium, Metal, Plastic, Steel, Wood Industry General Purpose Manufacturer Resinlab Chemistry Epoxy Cure Method 2-Part Cure, Room temperature curing, Heat Cure Cure Temperature (°C) 75, 25, 150 Cure Time (min) 1,440, 10 Viscosity (cPs) Non-sag, 185,000, Smooth High Temperature Resistance (°C) 205 Low Temperature Resistance (°C) -40 -
Technical Data for Resinlab Armstrong A-661
Overview
Specifications
Cure Specs
Cure Temperature (°C) 75, 25, 150 Test Method Cure Time (min) 1,440, 10 Test Method Viscosity (cPs) Non-sag, 185,000, Smooth Test Method Fixture or Handling Strength Time (min) Overnight Test Method Work / Pot Time (min) 180, 81 Test Method Thixotropic Thixotropic Mix Ratio 4:1 (by weight), 2.5:1 (by volume) Bond Strength
General Bond Strength (psi) 5,300 Test Method Shear Strength (psi) Excellent, 3,300, 3,460, 760, 430 Test Method Tensile Strength (psi) 2,800 Test Method Material Resistance
High Temperature Resistance (°C) 205 Test Method Low Temperature Resistance (°C) -40 Test Method Hardness
Elongation (%) 2 Test Method Other Properties
Specific Gravity 1.410 Test Method Business Information
Shelf Life Details Store below 25°C out of sunlight and in original unopened containers. Refer to packaging specific quote for shelf life information., 12 months at 25 °C in bulk packages; Storage at 25 +/- 10 °C is optimum for most products., 9 months DOP at 25 °C in C-kit.; Storage at 25 +/- 10 °C is optimum for most products. Shelf Life Temperature (°F) <77, 77, 77 Shelf Life Type Shelf Life Type, DOP Shelf Life (mon) 12, 9 -
Best Practices for Resinlab Armstrong A-661
-
Application
Easy to apply
-
Mixing
Bring both components to room temperature prior to mixing.
Cartridge format: Mixer should be attached keeping the cartridge vertical and any air pocket purged this way. After the mixer contains material, the mixer tip can be dropped to dispense pre-bleed amount. Attach a new static mixer with each cartridge, then pre-bleed the first 3 inches of dispensed material or until a uniform color is obtained. Maintain adequate velocity during dispensing to ensure complete mixing.
Bulk format: weigh and mix parts A and B accurately and thoroughly, scraping sides of container often. Do not pour from mixing container, transfer to a new container as residual unmixed material may cause a tacky spot on the surface of the casting. Maintain adequate velocity during dispensing to ensure complete mixing.
-
Curing
Allow to cure undisturbed until product is fully gelled or tack-free to the touch.
-
Clean-Up
Clean up uncured resin with suitable organic solvent such as MEK, acetone or other organic solvent.
-
-
Comparable Materials for Resinlab Armstrong A-661
Spec Engine® Results
Closest Results from this Manufacturer
Popular Articles
Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleElectrically Conductive Adhesives
Read ArticleEpoxy Adhesives for Medical Devices
Read ArticleTesting the effectiveness of surface treatments
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Cure Temperature Test Methods
Cure Temperature | Cure Time Test Method |
---|---|
75°C | Elevated cure |
25°C | |
150°C |
Viscosity Test Methods
Viscosity | Test Method | Temperature |
---|---|---|
Non-sag | ||
185,000 cPs | Mixed, @1/s, Rheometer parallel plate 25mm 455300006291 | 25°C |
Smooth |
Work / Pot Time Test Methods
Work / Pot Time | Test Method | Temperature |
---|---|---|
180 min | Work Life, 100g sample, Extrapolated from Henkel LDS | 25°C |
81 min | Pot Life, defined as the time it takes for initial mixed viscosity to double, Rheometer parallel plate 25mm@1/s 455300006291 | 25°C |
Cure Time Test Methods
Cure Time | Test Method |
---|---|
1,440 min | |
10 min |
Fixture or Handling Strength Time Test Methods
Fixture or Handling Strength Time | Fixture-Handling Strength Time Temperature |
---|---|
Overnight | 20 to 25°C Room Temperature |
Shear Strength Test Methods
Shear Strength | Type | Cure Time | Cure Temperature | Substrate |
---|---|---|---|---|
Excellent | ||||
3,300 psi | Lap Shear Strength | 25°C | 0.005” bond line Al to Al | |
3,460 psi | Lap Shear Strength | 82°C | 0.005” bond line Al to Al | |
760 psi | Lap Shear Strength | 10 min | 149°C | 0.005” bond line Al to Al |
430 psi | Lap Shear Strength | 204°C | 0.005” bond line Al to Al |
Tensile Strength Test Methods
Tensile Strength | Cure Time | Cure Temperature | Test Temperature |
---|---|---|---|
2,800 psi | 10 min | 149°C | 25°C |
General Bond Strength Test Methods
General Bond Strength | Type | Cure Time | Cure Temperature |
---|---|---|---|
5,300 psi | Tensile Bond Strength | 10 min | 149°C |
High Temperature Resistance Test Methods
High Temperature Resistance | Test Method |
---|---|
205°C | Operating Temperature Range is based on average design requirements and is not intended as a guarantee of suitability for all |
Low Temperature Resistance Test Methods
Low Temperature Resistance | Test Method |
---|---|
-40°C | Operating Temperature Range is based on average design requirements and is not intended as a guarantee of suitability for all |
Elongation Test Methods
Elongation | Test Method |
---|---|
2 % | Tensile Elongation, Extrapolated from Henkel LDS Cured 10 minutes @ 149 °C |
Specific Gravity Test Methods
Specific Gravity | Test Method |
---|---|
1.410 | Mixed, Calculated |