Resinlab Armstrong A-661 Datasheet Resinlab Armstrong A-661

Information provided by Gluespec
  • Description for Resinlab Armstrong A-661

    A two-part, smooth, brushable, non-sag, room temperature curing adhesive that produces bonds with excellent shear strength. Easy to apply paste that cures to handling strength overnight at room temperature.

    *See Terms of Use Below

    Brand Armstrong
    Application Type Bond
    1 Part or 2 Part 2-Part
    Material Form Paste
    Substrate Ceramic, Aluminium, Metal, Plastic, Steel, Wood
    Industry General Purpose
    Manufacturer Resinlab
    Chemistry Epoxy
    Cure Method 2-Part Cure, Room temperature curing, Heat Cure
    Cure Temperature (°C) 75, 25, 150
    Cure Time (min) 1,440, 10
    Viscosity (cPs) Non-sag, 185,000, Smooth
    High Temperature Resistance (°C) 205
    Low Temperature Resistance (°C) -40
  • Technical Data for Resinlab Armstrong A-661

    Overview
    • Application Type
    • 1 Part or 2 Part
      • 2-Part
    • Material Form
      • Paste
    • Substrate
    • Industry
      • General Purpose
    • Chemistry
    • Application Method
      • Brush - Brushable
    • Cure Method
      • Room Temperature / Air Dry - Room temperature curing
      • Heat - Heat Cure
      • 2-Part Cure
    • Brand
      • Armstrong
    Specifications
    Cure Specs
    Cure Temperature (°C) 75, 25, 150 Test Method
    Cure Time (min) 1,440, 10 Test Method
    Viscosity (cPs) Non-sag, 185,000, Smooth Test Method
    Fixture or Handling Strength Time (min) Overnight Test Method
    Work / Pot Time (min) 180, 81 Test Method
    Thixotropic Thixotropic
    Mix Ratio 4:1 (by weight), 2.5:1 (by volume)
    Bond Strength
    General Bond Strength (psi) 5,300 Test Method
    Shear Strength (psi) Excellent, 3,300, 3,460, 760, 430 Test Method
    Tensile Strength (psi) 2,800 Test Method
    Material Resistance
    High Temperature Resistance (°C) 205 Test Method
    Low Temperature Resistance (°C) -40 Test Method
    Hardness
    Elongation (%) 2 Test Method
    Other Properties
    Specific Gravity 1.410 Test Method
    Business Information
    Shelf Life Details Store below 25°C out of sunlight and in original unopened containers. Refer to packaging specific quote for shelf life information., 12 months at 25 °C in bulk packages; Storage at 25 +/- 10 °C is optimum for most products., 9 months DOP at 25 °C in C-kit.; Storage at 25 +/- 10 °C is optimum for most products.
    Shelf Life Temperature (°F) <77, 77, 77
    Shelf Life Type Shelf Life Type, DOP
    Shelf Life (mon) 12, 9
  • Best Practices for Resinlab Armstrong A-661

    *See Terms of Use Below

    1. Application

      Easy to apply

    2. Mixing

      Bring both components to room temperature prior to mixing.

      Cartridge format: Mixer should be attached keeping the cartridge vertical and any air pocket purged this way. After the mixer contains material, the mixer tip can be dropped to dispense pre-bleed amount. Attach a new static mixer with each cartridge, then pre-bleed the first 3 inches of dispensed material or until a uniform color is obtained. Maintain adequate velocity during dispensing to ensure complete mixing.

      Bulk format: weigh and mix parts A and B accurately and thoroughly, scraping sides of container often. Do not pour from mixing container, transfer to a new container as residual unmixed material may cause a tacky spot on the surface of the casting. Maintain adequate velocity during dispensing to ensure complete mixing.

    3. Curing

      Allow to cure undisturbed until product is fully gelled or tack-free to the touch.

    4. Clean-Up

      Clean up uncured resin with suitable organic solvent such as MEK, acetone or other organic solvent.

  • Comparable Materials for Resinlab Armstrong A-661

    *See Terms of Use Below

    Spec Engine® Results

    Closest Results from this Manufacturer

Popular Articles

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

Electrically Conductive Adhesives

Read Article

Epoxy Adhesives for Medical Devices

Read Article

Testing the effectiveness of surface treatments

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article

Featured Ads

Top Catalog Pages for Resinlab Armstrong A-661

Gluespec Poll

When you're researching or sourcing materials online, what device are you using?
Cure Temperature Test Methods
Cure Temperature Cure Time Test Method
75°C Elevated cure
25°C
150°C
Viscosity Test Methods
Viscosity Test Method Temperature
Non-sag
185,000 cPs Mixed, @1/s, Rheometer parallel plate 25mm 455300006291 25°C
Smooth
Work / Pot Time Test Methods
Work / Pot Time Test Method Temperature
180 min Work Life, 100g sample, Extrapolated from Henkel LDS 25°C
81 min Pot Life, defined as the time it takes for initial mixed viscosity to double, Rheometer parallel plate 25mm@1/s 455300006291 25°C
Cure Time Test Methods
Cure Time Test Method
1,440 min
10 min
Fixture or Handling Strength Time Test Methods
Fixture or Handling Strength Time Fixture-Handling Strength Time Temperature
Overnight 20 to 25°C Room Temperature
Shear Strength Test Methods
Shear Strength Type Cure Time Cure Temperature Substrate
Excellent
3,300 psi Lap Shear Strength 25°C 0.005” bond line Al to Al
3,460 psi Lap Shear Strength 82°C 0.005” bond line Al to Al
760 psi Lap Shear Strength 10 min 149°C 0.005” bond line Al to Al
430 psi Lap Shear Strength 204°C 0.005” bond line Al to Al
Tensile Strength Test Methods
Tensile Strength Cure Time Cure Temperature Test Temperature
2,800 psi 10 min 149°C 25°C
General Bond Strength Test Methods
General Bond Strength Type Cure Time Cure Temperature
5,300 psi Tensile Bond Strength 10 min 149°C
High Temperature Resistance Test Methods
High Temperature Resistance Test Method
205°C Operating Temperature Range is based on average design requirements and is not intended as a guarantee of suitability for all
Low Temperature Resistance Test Methods
Low Temperature Resistance Test Method
-40°C Operating Temperature Range is based on average design requirements and is not intended as a guarantee of suitability for all
Elongation Test Methods
Elongation Test Method
2 % Tensile Elongation, Extrapolated from Henkel LDS Cured 10 minutes @ 149 °C
Specific Gravity Test Methods
Specific Gravity Test Method
1.410 Mixed, Calculated