Description for Elantas (Altana) Conapoxy RN-1000 w/ EA-02 Hardener
A diluted epoxy potting and casting resin. When cured with the hardeners listed, these systems possess low shrinkage, low exotherm, good thermal shock and electrical properties.Brand Cytec, Conapoxy Application Type Casting, Potting, Encapsulation 1 Part or 2 Part 2 Part Material Form Liquid Industry Electrical devices, Transformers, Coils, Electronic devices, Modules Manufacturer Elantas (Altana) Chemistry Epoxy Cure Method 2-Part Cure Cure Temperature (°C) 20 to 25 Room temperature, 25, 60 Cure Time (min) 1,440, 120 Viscosity (cPs) Low, 600 Color Amber Arc Resistance (sec) Very good arc resistance High Temperature Resistance (°C) Good thermal shock resistance
Popular Articles
Testing the effectiveness of surface treatments
Read ArticleInfographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleThe effectiveness of adhesives in the wind power industry
Read ArticleEpoxies in the Aerospace Industry
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Set Time Test Methods
Set Time | Set Temperature | Test Method |
---|---|---|
30 min | 25°C | Gel Time, Mixed |
Viscosity Test Methods
Viscosity | Test Method | Temperature |
---|---|---|
Low | ||
600 cPs | Mixed, initial | 25°C |
Compressive Strength Test Methods
Compressive Strength | Cure Temperature | Test Method |
---|---|---|
15,000 psi | 25°C | ASTM D149 |
Tensile Strength Test Methods
Tensile Strength | Cure Temperature | Test Method |
---|---|---|
10,000 psi | 25°C | ASTM D412 |
Dielectric Constant Test Methods
Dielectric Constant | Temperature | Test Method |
---|---|---|
3.50 | 25°C | ASTM D150, 1 kHz |
Dielectric Strength Test Methods
Dielectric Strength | Temperature | Test Method |
---|---|---|
350 V/mil | 25°C | ASTM D149 |
Good |
Dissipation Factor Test Methods
Dissipation Factor | Temperature | Test Method |
---|---|---|
0.00200 | 25°C | ASTM D150, 1 kHz |
Surface Resistivity Test Methods
Surface Resistivity | Temperature | Test Method |
---|---|---|
2.0e15 (ohms) | 25°C | ASTM D257 |
Volume Resistivity Test Methods
Volume Resistivity | Temp (°C) | Test Method |
---|---|---|
3.0e14 (ohms/cm) | 25°C | ASTM D257 |
Glass Transition Temp (Tg) Test Methods
Glass Transition Temp (Tg) | Glass Transition Temperature (Tg) Test Method |
---|---|
80 to 185°C | DSC |
Specific Gravity Test Methods
Specific Gravity | Temperature |
---|---|
1.128 | 25°C |