Description for Elantas (Altana) Conathane TU-401 w/ TU-901
A new two-component, liquid casting system - free from MbOCA, TDI, MDA, and Hg catalyst- that produces flexible elastomers of exceptional toughness, high elongation, high tensile and tear strength.Brand Conathane, Cytec Chemical Resistance Good chemical resistance, Chemical Resistance: Good solvent resistance Application Type Casting, Potting 1 Part or 2 Part 2-Part Material Form Liquid Industry Potting and casting of industrial wheels, Potting and casting of bushings Manufacturer Elantas (Altana) Chemistry Non-MbOCA Cure Method Resin/Hardener, Room temperature curing Cure Temperature (°C) 80, 20 to 25, 80, 25 Cure Time (min) 120, 1,440, 960, 10,080 to 30,240 Viscosity (cPs) Low, 3,000, 3,000 to 5,000, 4,000 Arc Resistance (sec) Arc Resistance Volume Resistivity (O) 7.6e12 (ohm-cm) Elastomeric Elastomeric properties Key Specifications UL94, pass V-2 Can Be Used In Conjunction With These Materials Gaskets -
Technical Data for Elantas (Altana) Conathane TU-401 w/ TU-901
Overview
-
Chemical Resistance
- Chemical Resistance - Good chemical resistance
- Chemical Resistance : Relative Solvent Resistance - Good solvent resistance
-
Application Type
- Casting / Moldmaking - Casting
- Pottant / Encapsulant - Potting
-
1 Part or 2 Part
- 2-Part
-
Material Form
- Liquid
-
Industry
- Industrial Wheels - Potting and casting of industrial wheels
- Bushing - Potting and casting of bushings
- Other - Potting and casting of vibration dampening pads, shock and sound dampening pads, Potting and casting of metal forming pads, Potting and casting of flexible molds, Potting and casting of washers, Diaphrams, Potting and casting of sound dampening pads, Potting and casting of shock dampening pads
-
Chemistry
- Other - Non-MbOCA
-
Application Method
- Dispenser - Automatic metering, Mixing equipment, Dispensing equipment
- Other - Hand-mix Bench Potting / Casting, Meter-mix Bench Potting / Casting, Meter-mix Vacuum Potting / Casting
-
Cure Method
- Room Temperature / Air Dry - Room temperature curing
- 2-Part Cure - Resin/Hardener
-
Key Specifications
- UL (Underwriters Laboratory), ULC (Underwriters Laboratories of Canada), NFPA (National Fire Protection Association) - UL94, pass V-2
-
Can Be Used In Conjunction With These Materials
- Gaskets
-
Brand
- Conathane
- Cytec
Specifications
Cure Specs
Cure Temperature (°C) 80, 20 to 25, 80, 25 Test Method Cure Time (min) 120, 1,440, 960, 10,080 to 30,240 Test Method Viscosity (cPs) Low, 3,000, 3,000 to 5,000, 4,000 Test Method Fixture or Handling Strength Time (min) Demold time Linear Shrinkage (%) 1.00, Undetectable, <0.50, 1.00 Test Method Work / Pot Time (min) 20 to 30 Test Method Mix Ratio Convienient (by volume), 100:45 (by volume), 100:44 (by weight) Bond Strength
Tear Strength (piw) High, 400 (pli) Test Method Tensile Strength (psi) High, 4,000, 600, 875, 1,000 Test Method Material Resistance
Dimensional Stability (%) Excellent physical properties Arc Resistance (sec) Arc Resistance Test Method Abrasion Resistance Excellent abrasion resistance UV Resistance UV Resistance, Excellent UV stability Test Method Conductivity
Dissipation Factor 0.07200, 0.02300, 0.07600, 0.07000, 0.02000, 0.08000 Test Method Dielectric Strength (V/mil) 579 (vpm), 580 1/16” Test Method Dielectric Constant 5.27, 5.12, 4.25, 5.30, 5.10, 4.30 Test Method Volume Resistivity (O) 7.6e12 (ohm-cm) Test Method Surface Resistivity (O) 3.5e14 ohms / sq. Test Method Hardness
Shore A Hardness 90 to 0 Test Method Elastomeric Elastomeric properties Elongation (%) High, 750 Test Method Flexibility Flexible Other Properties
% Solids (%) 100 Business Information
Shelf Life Details CONATHANE TU-401 Part A and TU-901 Part B have a storage life of at least 18 months from date of manufacture, when stored in their original unopened containers at 65F-85F, Store below 25°C / 77°F in a dry controlled environment out of direct sunlight. This material should be suitable for use stored under these conditions in the original sealed containers for twelve (12) months from the date of shipment. Shelf Life Temperature (°F) 65 to 85, <77 Shelf Life Type From date of manufacture, From the date of shipment Shelf Life (mon) 18, 12 -
-
Best Practices for Elantas (Altana) Conathane TU-401 w/ TU-901
-
Surface Preparation
When curing TU-901 at 80°C or above, the recommended primer is CONAP® AD-1147 or AD-1147-C.
It is important that all dirt, grease, and oil be removed from surfaces prior to applying the primers.
-
Application
Pour mixed material into molds or fixtures in a manner to avoid trapping air bubbles or pockets, and cure as recommended. Porous molds should be properly sealed prior to using. Contact Cytec's customer service department or your Regional Sales Manager for assistance.
If parts are to be demolded, a quality CONAP® mold release should be applied prior to pouring.
-
Mixing
Mix the TU-401 Part A and TU-901 Part B in the ratio specified above until homogeneous. Components may be preheated up to 60°C if reduced viscosity is required. If hand mixing, degas at >27 in. Hg vacuum before use.
-
Clean-Up
Equipment may be cleaned with Methyl Ethyl Ketone or other hydrocarbon solvents.
-
-
Comparable Materials for Elantas (Altana) Conathane TU-401 w/ TU-901
Spec Engine® Results
Popular Articles
Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleTesting the effectiveness of surface treatments
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Cure Temperature Test Methods
Cure Temperature | Cure Time Test Method |
---|---|
80°C | Cytec |
20 to 25°C | Cytec |
80°C | |
25°C |
Cure Time Test Methods
Cure Time | Test Method |
---|---|
120 min | Cytec |
1,440 min | Cytec |
960 min | |
10,080 to 30,240 min |
Linear Shrinkage Test Methods
Linear Shrinkage | Test Method | Temp |
---|---|---|
1.00 % | Cytec | 80°C |
Undetectable | Cytec | 25°C |
<0.50 % | ASTM D2566 | 25 to 80°C |
1.00 % |
Viscosity Test Methods
Viscosity | Test Method | Temperature |
---|---|---|
Low | ||
3,000 cPs | 25°C | |
3,000 to 5,000 cPs | 25°C | |
4,000 cPs | Mixed; initial | 25°C |
Work / Pot Time Test Methods
Work / Pot Time | Test Method | Temperature |
---|---|---|
20 to 30 min | Work Life, Mixed |
Tensile Strength Test Methods
Tensile Strength | Test Method |
---|---|
High | |
4,000 psi | ASTM D412 |
600 psi | 100% Modulus, ASTM D412 |
875 psi | 200% Modulus, ASTM D412 |
1,000 psi | 300% Modulus, ASTM D412 |
Tear Strength Test Methods
Tear Strength | Test Method |
---|---|
High | |
400 (pli) | Graves, ASTM D624 |
UV Resistance Test Methods
UV Resistance | Test Method |
---|---|
UV Resistance | ASTM G-53 |
Excellent UV stability |
Arc Resistance Test Methods
Arc Resistance | Test Method |
---|---|
Arc Resistance | MIL-M-24041C, > 120 seconds |
Dielectric Constant Test Methods
Dielectric Constant | Temperature | Test Method |
---|---|---|
5.27 | 25°C | ASTM D150, 100 Hz |
5.12 | 25°C | ASTM D150, 1 KHz |
4.25 | 25°C | ASTM D150, 1 MHz |
5.30 | 25°C | ASTM D150, 100 Hz |
5.10 | 25°C | ASTM D150, 1 KHz |
4.30 | 25°C | ASTM D150, 1 MHz |
Dielectric Strength Test Methods
Dielectric Strength | Temperature | Test Method |
---|---|---|
579 (vpm) | ASTM D149 | |
580 V/mil 1/16” | 25°C |
Dissipation Factor Test Methods
Dissipation Factor | Temperature | Test Method |
---|---|---|
0.07200 | 25°C | ASTM D150, 100 Hz |
0.02300 | 25°C | ASTM D150, 1 KHz |
0.07600 | 25°C | ASTM D150, 1 MHz |
0.07000 | 25°C | ASTM D150, 100 Hz |
0.02000 | 25°C | ASTM D150, 1 kHz |
0.08000 | 25°C | ASTM D150, 1 MHz |
Volume Resistivity Test Methods
Volume Resistivity | Temp (°C) | Test Method |
---|---|---|
7.6e12 (ohm-cm) | 25°C | ASTM D257 |
Surface Resistivity Test Methods
Surface Resistivity | Temperature | Test Method |
---|---|---|
3.5e14 ohms / sq. | 25°C | ASTM D257 |
Elongation Test Methods
Elongation | Test Method |
---|---|
High | |
750 % | ASTM D412 |
Shore A Hardness Test Methods
Shore A Hardness | Shore Hardness Test Method |
---|---|
90 to 0 | ASTM D412 |

1 VIEW FREE
Don't Leave!
View Elantas (Altana) - Conathane TU-401 w/ TU-901 now.