Elantas (Altana) Conathane TU-401 w/ TU-901 Datasheet Elantas (Altana) Conathane TU-401 w/ TU-901

Information provided by Gluespec
  • Description for Elantas (Altana) Conathane TU-401 w/ TU-901

    A new two-component, liquid casting system - free from MbOCA, TDI, MDA, and Hg catalyst- that produces flexible elastomers of exceptional toughness, high elongation, high tensile and tear strength.

    *See Terms of Use Below

    Brand Conathane, Cytec
    Chemical Resistance Good chemical resistance, Chemical Resistance: Good solvent resistance
    Application Type Casting, Potting, Gaskets
    1 Part or 2 Part 2 Part
    Material Form Liquid
    Industry Industrial wheels
    Manufacturer Elantas (Altana)
    Chemistry Non-MbOCA
    Cure Method Resin/Hardener, Room temperature curing
    Cure Temperature (°C) 80, 20 to 25, 80, 25
    Cure Time (min) 120, 1,440, 960, 10,080 to 30,240
    Viscosity (cPs) Low, 3,000, 3,000 to 5,000, 4,000
    Arc Resistance (sec) Arc Resistance
    Elastomeric Elastomeric properties
    Key Specifications UL94, pass V-2

Popular Articles

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

Testing the effectiveness of surface treatments

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article

Featured Ads

Top Catalog Pages for Elantas (Altana) Conathane TU-401 w/ TU-901

Gluespec Poll

What level of expertise do you have in specialty chemicals like adhesives, sealants, conformal coatings, etc.?
Cure Temperature Test Methods
Cure Temperature Cure Time Test Method
80°C Cytec
20 to 25°C Cytec
80°C
25°C
Cure Time Test Methods
Cure Time Test Method
120 min Cytec
1,440 min Cytec
960 min
10,080 to 30,240 min
Linear Shrinkage Test Methods
Linear Shrinkage Test Method Temp
1.00 % Cytec 80°C
Undetectable Cytec 25°C
<0.50 % ASTM D2566 25 to 80°C
1.00 %
Viscosity Test Methods
Viscosity Test Method Temperature
Low
3,000 cPs 25°C
3,000 to 5,000 cPs 25°C
4,000 cPs Mixed; initial 25°C
Work / Pot Time Test Methods
Work / Pot Time Test Method Temperature
20 to 30 min Work Life, Mixed
Tear Strength Test Methods
Tear Strength Test Method
High
400 (pli) Graves, ASTM D624
Tensile Strength Test Methods
Tensile Strength Test Method
High
4,000 psi ASTM D412
600 psi 100% Modulus, ASTM D412
875 psi 200% Modulus, ASTM D412
1,000 psi 300% Modulus, ASTM D412
UV Resistance Test Methods
UV Resistance Test Method
UV Resistance ASTM G-53
Excellent UV stability
Arc Resistance Test Methods
Arc Resistance Test Method
Arc Resistance MIL-M-24041C, > 120 seconds
Dielectric Constant Test Methods
Dielectric Constant Temperature Test Method
5.27 25°C ASTM D150, 100 Hz
5.12 25°C ASTM D150, 1 KHz
4.25 25°C ASTM D150, 1 MHz
5.30 25°C ASTM D150, 100 Hz
5.10 25°C ASTM D150, 1 KHz
4.30 25°C ASTM D150, 1 MHz
Dielectric Strength Test Methods
Dielectric Strength Temperature Test Method
579 (vpm) ASTM D149
580 V/mil 1/16” 25°C
Dissipation Factor Test Methods
Dissipation Factor Temperature Test Method
0.07200 25°C ASTM D150, 100 Hz
0.02300 25°C ASTM D150, 1 KHz
0.07600 25°C ASTM D150, 1 MHz
0.07000 25°C ASTM D150, 100 Hz
0.02000 25°C ASTM D150, 1 kHz
0.08000 25°C ASTM D150, 1 MHz
Surface Resistivity Test Methods
Surface Resistivity Temperature Test Method
3.5e14 ohms / sq. 25°C ASTM D257
Volume Resistivity Test Methods
Volume Resistivity Temp (°C) Test Method
7.6e12 (ohm-cm) 25°C ASTM D257
Elongation Test Methods
Elongation Test Method
High
750 % ASTM D412
Shore A Hardness Test Methods
Shore A Hardness Shore Hardness Test Method
90 to 0 ASTM D412