Description for Elantas (Altana) FP-1305
A two-component, non-TDI, liquid polyurethane casting system produced under very carefully controlled conditions. This elastomeric system features excellent toughness, water resistance, and physical properties.Brand Cytec Chemical Resistance Chemical Resistance: Fluid Resistance: Water resistance Application Type Casting 1 Part or 2 Part 2 Part Material Form Liquid Industry Medical, General purpose potting compound Manufacturer Elantas (Altana) Chemistry polyurethane Cure Method Resin/Hardener Cure Temperature (°C) 50, 25, 80, 25 Cure Time (min) 300, 10,080, 240, 960 Viscosity (cPs) 4,000, 900 Color Clear Light Amber
Popular Articles
Testing the effectiveness of surface treatments
Read ArticleInfographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleCharacteristics of MMAs
Read ArticleThe effectiveness of adhesives in the wind power industry
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Viscosity Test Methods
Viscosity | Temperature |
---|---|
4,000 cPs | 25°C |
900 cPs | 50°C |
Work / Pot Time Test Methods
Work / Pot Time | Temperature |
---|---|
15 min | 60°C |
Tensile Strength Test Methods
Tensile Strength | Test Method |
---|---|
3,200 psi | ASTM D412, Die C |
Tear Strength Test Methods
Tear Strength | Test Method |
---|---|
450 (pli) | ASTM D624, Die C |
Elongation Test Methods
Elongation | Test Method |
---|---|
150 % | ASTM D412, Die C |
Shore A Hardness Test Methods
Shore A Hardness | Shore Hardness Test Method |
---|---|
44 | ASTM D2240,After 30 minutes @ 60°C |
95 | ASTM D2240, Fully Cured |
Specific Gravity Test Methods
Specific Gravity | Test Method |
---|---|
1.150 | ASTM D1475 |
0.970 | ASTM D1475 |