Elantas (Altana) TU-6090 Datasheet Elantas (Altana) TU-6090

Information provided by Gluespec
  • Description for Elantas (Altana) TU-6090

    A two-component polyurethane casting system formulated to produce 90 Shore A elastomers.

    *See Terms of Use Below

    Brand Conathane, Cytec
    Application Type Casting, Potting
    1 Part or 2 Part 2-Part
    Material Form Liquid
    Industry Potting and casting of industrial wheels, Potting and casting of bushings
    Manufacturer Elantas (Altana)
    Chemistry Polyurethane
    Cure Method Resin/Hardener
    Cure Temperature (°C) 25, 80, 60
    Cure Time (min) 10,080 to 14,400, 960, 960
    Viscosity (cPs) 3,100
    Color Amber
    Can Be Used In Conjunction With These Materials Gaskets
  • Technical Data for Elantas (Altana) TU-6090

    Overview
    • Application Type
    • 1 Part or 2 Part
      • 2-Part
    • Material Form
      • Liquid
    • Industry
      • Industrial Wheels - Potting and casting of industrial wheels
      • Bushing - Potting and casting of bushings
      • Other - Potting and casting of metal forming pads, Potting and casting of flexible molds, Potting and casting of washers, Potting and casting of vibration dampening pads, Potting and casting of shock dampening pads, Potting and casting of sound dampening pads
    • Chemistry
    • Application Method
      • Other - Hand-mix Bench Potting / Casting, Meter-mix Bench Potting / Casting, Meter-mix Vacuum Potting / Casting
    • Cure Method
      • 2-Part Cure - Resin/Hardener
    • Color
      • Red - Amber
    • Can Be Used In Conjunction With These Materials
      • Gaskets
    • Brand
      • Conathane
      • Cytec
    Specifications
    Cure Specs
    Cure Temperature (°C) 25, 80, 60 Test Method
    Cure Time (min) 10,080 to 14,400, 960, 960 Test Method
    Viscosity (cPs) 3,100 Test Method
    Work / Pot Time (min) 15 to 20 Test Method
    Mix Ratio 100:50 (by volume), 100:50 (by weight)
    Bond Strength
    Tear Strength (piw) 390 (pli) Test Method
    Tensile Strength (psi) 2,840, 1,000, 2,380, 2,850, 1,000, 2,800 Test Method
    Material Resistance
    Dimensional Stability (%) Excellent physical properties
    Hardness
    Shore A Hardness 90 Test Method
    Elongation (%) 335 Test Method
    Other Properties
    % Solids (%) 100
    Business Information
    Shelf Life Details 18 months from date of manufacture when stored in the orignial unopened containers at 70°F-85°F., Store below 25°C / 77°F in a dry controlled environment out of direct sunlight. This material should be suitable for use stored under these conditions in the original sealed containers for twelve (12) months from the date of shipment.
    Shelf Life Temperature (°F) 70 to 85, <77
    Shelf Life Type From date of manufacture, From the date of shipment
    Shelf Life (mon) 18, 12
  • Best Practices for Elantas (Altana) TU-6090

    *See Terms of Use Below

    1. Mixing

      Mix the TU-6090 Part A and TU-6090 Part B in the ratio specified above until homogeneous. Components may be preheated up to 60°C if reduced viscosity is required. If hand mixing, degas at >27 in. Hg vacuum before use.

      Cure 7 - 10 days at 25°C / 77°F – or – 16 hours at 60°C / 140°F

  • Comparable Materials for Elantas (Altana) TU-6090

    *See Terms of Use Below

    Spec Engine® Results

Popular Articles

Testing the effectiveness of surface treatments

Read Article

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

Characteristics of MMAs

Read Article

The effectiveness of adhesives in the wind power industry

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article

Featured Ads

Top Catalog Pages for Elantas (Altana) TU-6090

Gluespec Poll

When you're researching or sourcing materials online, what device are you using?
Cure Temperature Test Methods
Cure Temperature Cure Time Test Method
25°C Full Cure
80°C Alternate Cure
60°C
Cure Time Test Methods
Cure Time Test Method
10,080 to 14,400 min Full Cure
960 min Alternate Cure
960 min
Viscosity Test Methods
Viscosity Test Method Temperature
3,100 cPs Mixed, initial 25°C
Work / Pot Time Test Methods
Work / Pot Time Test Method Temperature
15 to 20 min Work Life, Mixed 25°C
Tear Strength Test Methods
Tear Strength Test Temperature Test Method
390 (pli) 25°C ASTM D412
Tensile Strength Test Methods
Tensile Strength Test Temperature Test Method
2,840 psi
1,000 psi 100% modulus
2,380 psi 300% modulus
2,850 psi 25°C ASTM D412
1,000 psi ASTM D412, 100% modulus
2,800 psi ASTM D412, 300% modulus
Elongation Test Methods
Elongation Test Method
335 % Ultimate Elongation, 25°C, ASTM D412
Shore A Hardness Test Methods
Shore A Hardness Shore Hardness Test Method Hardness Temperature
90 ASTM D2240 25°C