Description for Elantas (Altana) UC-23
A two-component modified urethane system that produces a tough, highly impact resistant elastoplastic. This liquid urethane casting system has excellent handling characteristics and will cure at room or elevated temperatures.Brand Cytec Application Type Casting/Molding 1 Part or 2 Part 2-Part Material Form Liquid Manufacturer Elantas (Altana) Chemistry Epoxy, urethane Cure Method Resin/Hardener Cure Temperature (°C) 25, 60 Viscosity (cPs) Low, 3,500 Color Light Amber Volume Resistivity (O) 4e13 (ohm-cm) Density (g/cm³) 0.03262 (lbs./cu.in.) -
Technical Data for Elantas (Altana) UC-23
Overview
-
Application Type
- Casting / Moldmaking - Casting/Molding
-
1 Part or 2 Part
- 2-Part
-
Material Form
- Liquid
-
Industry
- Industrial
- Other - Typical applications include making fixtures, patterns, structural parts, metal stamping pads
-
Chemistry
- Epoxy
- Polyurethane - urethane
-
Cure Method
- 2-Part Cure - Resin/Hardener
-
Color
- Red - Light Amber
-
Brand
- Cytec
Specifications
Cure Specs
Cure Temperature (°C) 25, 60 Viscosity (cPs) Low, 3,500 Test Method Fixture or Handling Strength Time (min) Excellent Linear Shrinkage (%) 0.0006 (in/in) Test Method Mix Ratio 100:25 (by volume), 100:20 (by weight) Bond Strength
Impact Strength (psi) 0.57 (Ft.-Pounds/Inch), 1.04 (Ft.-Pounds/Inch), 0.71 (Ft.-Pounds/Inch), 1.07 (Ft.-Pounds/Inch) Test Method Flexural Strength (psi) 8,460 Tear Strength (piw) 350 (pli) Test Method Tensile Strength (psi) High, 5,300 Test Method Material Resistance
Abrasion Resistance good abrasion resistance Impact Resistance impact resistant elastoplastic Conductivity
Dissipation Factor 0.02400 Test Method Dielectric Strength (V/mil) 480 (vpm) Test Method Dielectric Constant 4.80 Test Method Volume Resistivity (O) 4e13 (ohm-cm) Test Method Hardness
Shore D Hardness 75 to 85 Test Method Elongation (%) 20 Test Method Modulus (psi) 241,350 Other Properties
Specific Gravity 1.040 Test Method % Solids (%) 100 Density (g/cm³) 0.03262 (lbs./cu.in.) Test Method Business Information
Shelf Life Details Storage and Handling: CONAP® UC-23, Parts A and B, have a shelf life of 18-months from date of manufacture when stored in their original unopened containers. While UC-23 is not moisture sensitive and does not require blanketing with nitrogen (see CONAP® Dri-Purge), it is suggested that opened containers be closed when not in use. Shelf Life Type From date of manufacture Shelf Life (mon) 18 -
-
Best Practices for Elantas (Altana) UC-23
-
Application
UC-23 has very good adhesion to most substrates and generally will not require the use of a primer. If adhesion improvement is necessary, contact Cytec Industries Inc. for specific recommendations. If the cast part is to be demolded after cure, apply Cytec mold release agents prior to casting. Castings can generally be demolded in 2-4 hours at room temperature.
-
Mixing
Thoroughly mix the two components together at the recommended ratio at 25°C stirring carefully to prevent entrapment of air.
-
Deairing/Degassing
If this is done carefully, degassing of the mixed material may not be necessary. If air entrapment is excessive, degas the mixture for 3-5 minutes at 1-5 mm of vacuum.
-
-
Comparable Materials for Elantas (Altana) UC-23
Spec Engine® Results
Closest Results from this Manufacturer
Popular Articles
Testing the effectiveness of surface treatments
Read ArticleInfographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleFireproofing EV Batteries
Read ArticleThe effectiveness of adhesives in the wind power industry
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Linear Shrinkage Test Methods
Linear Shrinkage | Test Method |
---|---|
0.0006 (in/in) | Cytec |
Set Time Test Methods
Set Time | Set Temperature | Test Method |
---|
Viscosity Test Methods
Viscosity | Temperature |
---|---|
Low | |
3,500 cPs | 25°C |
Work / Pot Time Test Methods
Work / Pot Time | Test Method | Temperature |
---|
Impact Strength Test Methods
Impact Strength | Cure Temperature | Test Method |
---|---|---|
0.57 (Ft.-Pounds/Inch) | 25°C | ASTM D256, Izod, Cured at Room Temperature, Notched |
1.04 (Ft.-Pounds/Inch) | 25°C | ASTM D256, Izod, Cured at Room Temperature, Unnotched |
0.71 (Ft.-Pounds/Inch) | 60°C | ASTM D256, Izod, Cured at 60°C, Notched |
1.07 (Ft.-Pounds/Inch) | 60°C | ASTM D256, Izod, Cured at 60°C, Unnotched |
Tear Strength Test Methods
Tear Strength | Test Method |
---|---|
350 (pli) | ASTM D624 |
Tensile Strength Test Methods
Tensile Strength | Test Method |
---|---|
High | |
5,300 psi | ASTM D412 |
Dielectric Constant Test Methods
Dielectric Constant | Temperature | Test Method |
---|---|---|
4.80 | 25°C | ASTM D150, 1 KHz |
Dielectric Strength Test Methods
Dielectric Strength | Test Method |
---|---|
480 (vpm) | ASTM D149, (1/16" Thick) |
Dissipation Factor Test Methods
Dissipation Factor | Temperature | Test Method |
---|---|---|
0.02400 | 25°C | ASTM D150, 1 KHz |
Volume Resistivity Test Methods
Volume Resistivity | Temp (°C) | Test Method |
---|---|---|
4e13 (ohm-cm) | 25°C | ASTM D257 |
Elongation Test Methods
Elongation | Test Method |
---|---|
20 % | ASTM D412 |
Shore D Hardness Test Methods
Shore D Hardness | Shore Hardness Test Method |
---|---|
75 to 85 | ASTM D2240 |
Density Test Methods
Density | Test Method |
---|---|
0.03262 (lbs./cu.in.) | ASTM D792 |
Specific Gravity Test Methods
Specific Gravity | Temperature | Test Method |
---|---|---|
1.040 | 25°C | ASTM D792 |