  • Description for Dow Dowsil HC 2100 Coating

    A one-part, translucent, fast tack free low viscosity conformal coating with controlled volatility, Cures to soft, low stress elastomer, RT cure.

    *See Terms of Use Below

    Brand Dowsil
    Chemical Resistance Good
    Application Type Conformal coating
    1 Part or 2 Part 1-Part
    Material Form Pre-Cure: Liquid, Post-Cure: Elastomer
    Substrate Low-surface energy surfaces
    Industry Connectors, Rigid circuit boards, Interconnections, Sensors, E-Mobility Solutions, Smart Meters, Smart Home Devices, Electronic components, Flexible circuit boards, Relays
    Manufacturer Dow
    Chemistry Silicone elastomer, Solventless, Non Volatile Content : 96.7%, Polydimethylsiloxane coating
    Application Method Flow: Flow coating
    Cure Method Atmospheric moisture, RTV, RT cure
    Cure Temperature (°C) 25 Room Temperature
    Cure Time (min) 30, 4,320
    Viscosity (cPs) High, 400, Low
    Color Translucent
    Ozone Resistance Ozone resistance
    High Temperature Resistance (°C) 200
    Low Temperature Resistance (°C) -45, -55
    Other Resistance Mechanical protection
    Volume Resistivity (O) 5.0 E15 (ohm*cm)
    Stress Relief Low stress
    Key Specifications UL (Underwriters Laboratory), ULC (Underwriters Laboratories of Canada), NFPA (National Fire Protection Association): Underwriters Laboratory (UL) 746E
  • Technical Data for Dow Dowsil HC 2100 Coating

    Overview
    • Chemical Resistance
      • Chemical Resistance - Good
    • Application Type
    • 1 Part or 2 Part
      • 1-Part
    • Material Form
      • Elastomer - Post-Cure: Elastomer
      • Liquid - Pre-Cure: Liquid
    • Substrate
      • Low Surface Energy - Low-surface energy surfaces
      • Other - Other substrates, Printed circuits, Most common materials, Most common substrates
    • Industry
      • Smart Meters
      • Smart Home Devices
      • E-Mobility Solutions
      • Electronics - Electronic components, Flexible circuit boards, Relays, Rigid circuit boards, Interconnections
      • Connectors
      • Sensors
      • Industrial - CD, DVD, HDD, Delicate components
    • Chemistry
      • VOC-free - Non Volatile Content : 96.7%
      • Solvent-Free - Solventless
      • Silicone - Silicone elastomer, Polydimethylsiloxane coating
    • Application Method
      • Dispenser - Robotic dispensing, Select coating, Syringe
      • Brush
      • Spray
      • Flow : Flow Coat - Flow coating
      • Dip
      • Screen Print - Automated pattern
    • Cure Method
      • Room Temperature / Air Dry - RT cure
      • Moisture / Condensation Cure - Atmospheric moisture
      • RTV (Room Temperature Vulcanization) - RTV
    • Color
      • Translucent
    • Key Specifications
      • UL (Underwriters Laboratory), ULC (Underwriters Laboratories of Canada), NFPA (National Fire Protection Association) : 746E - Underwriters Laboratory (UL) 746E
    • Brand
      • Dowsil
    Specifications
    Cure Specs
    Cure Temperature (°C) 25 Room Temperature Test Method
    Cure Time (min) 30, 4,320 Test Method
    Viscosity (cPs) High, 400, Low Test Method
    Tack Free Time (min) Fast, 10 Test Method
    Work / Pot Time (min) >86,400 Test Method
    Bond Strength
    General Bond Strength (psi) Good
    Material Resistance
    Ozone Resistance Ozone resistance
    UV Resistance UV resistance
    Environmental Resistance Environmental protection
    High Temperature Resistance (°C) 200
    Low Temperature Resistance (°C) -45, -55
    Moisture/Humidity Resistance Moisture/humidity resistance
    Other Resistance Mechanical protection
    Conductivity
    Dissipation Factor 0.00100 Test Method
    Dielectric Strength (V/mil) Durable, 625 Test Method
    Dielectric Constant 2.40 Test Method
    Volume Resistivity (O) 5.0 E15 (ohm*cm) Test Method
    Hardness
    Stress Relief Low stress
    Shore A Hardness 10 Test Method
    Flexibility Soft
    Other Properties
    Specific Gravity 0.980 Test Method
    % Solids (%) 100
    Business Information
    Shelf Life Details Storage conditions and shelf life (“Use by” date) are indicated on the product label., Shelf life is indicated by the “Use Before” date found on the product label.
    Shelf Life Type From date of manufacture
    Shelf Life (mon) 15
  • Best Practices for Dow Dowsil HC 2100 Coating

    *See Terms of Use Below

    1. Curing

      Time to cure is dependent on several variables including the method of application, film thickness, temperature and humidity. Tack-free time in the data table gives an indication of typical times until surface is dry enough to handle. Cure time for full cure are indications of time needed to develop full physical properties such as durometer, tensile strength or adhesion. These times, including full cure time, can be significantly improved by introducing mild heat of 60°C or less.

  • Comparable Materials for Dow Dowsil HC 2100 Coating

    *See Terms of Use Below

    Spec Engine® Results

    Closest Results from this Manufacturer

Popular Articles

Silicones in LED Lighting | Gluespec

Read Article

Electronic Component Adhesives Guide

Read Article

Testing the effectiveness of surface treatments

Read Article

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article

Featured Ads

Top Catalog Pages for Dow Dowsil HC 2100 Coating

Gluespec Poll

Which answer best describes a project you are currently working on?
Cure Temperature Test Methods
Cure Temperature Cure Time Test Method
25°C Room Temperature 50% RH, 0.3 mm, These values are not intended for use in preparing specifications.
Cure Time Test Methods
Cure Time Test Method
30 min 50% RH, 0.3 mm, These values are not intended for use in preparing specifications.
4,320 min
Tack Free Time Test Methods
Tack Free Time Tack Free Temperature Test Method
Fast
10 min 25°C These values are not intended for use in preparing specifications.
Viscosity Test Methods
Viscosity Test Method
High
400 cPs These values are not intended for use in preparing specifications.
Low
Work / Pot Time Test Methods
Work / Pot Time Temperature
>86,400 min <29°C
Dielectric Constant Test Methods
Dielectric Constant Test Method
2.40 1 MHz
Dielectric Strength Test Methods
Dielectric Strength Test Method
Durable
625 V/mil JIS K 6249, These values are not intended for use in preparing specifications.
Dissipation Factor Test Methods
Dissipation Factor Test Method
0.00100 @ 1MHz (JIS K 6249), These values are not intended for use in preparing specifications.
Volume Resistivity Test Methods
Volume Resistivity Test Method
5.0 E15 (ohm*cm) These values are not intended for use in preparing specifications.
Shore A Hardness Test Methods
Shore A Hardness Shore Hardness Test Method
10 These values are not intended for use in preparing specifications.
Specific Gravity Test Methods
Specific Gravity Test Method
0.980 Cured, These values are not intended for use in preparing specifications.