Description for Dow Dowsil HC 2100 Coating
A one-part, translucent, fast tack free low viscosity conformal coating with controlled volatility, Cures to soft, low stress elastomer, RT cure.Brand Dowsil Chemical Resistance Good Application Type Conformal coating 1 Part or 2 Part 1-Part Material Form Pre-Cure: Liquid, Post-Cure: Elastomer Substrate Low-surface energy surfaces Industry Connectors, Rigid circuit boards, Interconnections, Sensors, E-Mobility Solutions, Smart Meters, Smart Home Devices, Electronic components, Flexible circuit boards, Relays Manufacturer Dow Chemistry Silicone elastomer, Solventless, Non Volatile Content : 96.7%, Polydimethylsiloxane coating Application Method Flow: Flow coating Cure Method Atmospheric moisture, RTV, RT cure Cure Temperature (°C) 25 Room Temperature Cure Time (min) 30, 4,320 Viscosity (cPs) High, 400, Low Color Translucent Ozone Resistance Ozone resistance High Temperature Resistance (°C) 200 Low Temperature Resistance (°C) -45, -55 Other Resistance Mechanical protection Volume Resistivity (O) 5.0 E15 (ohm*cm) Stress Relief Low stress Key Specifications UL (Underwriters Laboratory), ULC (Underwriters Laboratories of Canada), NFPA (National Fire Protection Association): Underwriters Laboratory (UL) 746E -
Technical Data for Dow Dowsil HC 2100 Coating
Overview
-
Chemical Resistance
- Chemical Resistance - Good
-
Application Type
-
1 Part or 2 Part
- 1-Part
-
Material Form
- Elastomer - Post-Cure: Elastomer
- Liquid - Pre-Cure: Liquid
-
Substrate
- Low Surface Energy - Low-surface energy surfaces
- Other - Other substrates, Printed circuits, Most common materials, Most common substrates
-
Industry
- Smart Meters
- Smart Home Devices
- E-Mobility Solutions
- Electronics - Electronic components, Flexible circuit boards, Relays, Rigid circuit boards, Interconnections
- Connectors
- Sensors
- Industrial - CD, DVD, HDD, Delicate components
-
Chemistry
- VOC-free - Non Volatile Content : 96.7%
- Solvent-Free - Solventless
- Silicone - Silicone elastomer, Polydimethylsiloxane coating
-
Application Method
- Dispenser - Robotic dispensing, Select coating, Syringe
- Brush
- Spray
- Flow : Flow Coat - Flow coating
- Dip
- Screen Print - Automated pattern
-
Cure Method
- Room Temperature / Air Dry - RT cure
- Moisture / Condensation Cure - Atmospheric moisture
- RTV (Room Temperature Vulcanization) - RTV
-
Color
- Translucent
-
Key Specifications
- UL (Underwriters Laboratory), ULC (Underwriters Laboratories of Canada), NFPA (National Fire Protection Association) : 746E - Underwriters Laboratory (UL) 746E
-
Brand
- Dowsil
Specifications
Cure Specs
Cure Temperature (°C) 25 Room Temperature Test Method Cure Time (min) 30, 4,320 Test Method Viscosity (cPs) High, 400, Low Test Method Tack Free Time (min) Fast, 10 Test Method Work / Pot Time (min) >86,400 Test Method Bond Strength
General Bond Strength (psi) Good Material Resistance
Ozone Resistance Ozone resistance UV Resistance UV resistance Environmental Resistance Environmental protection High Temperature Resistance (°C) 200 Low Temperature Resistance (°C) -45, -55 Moisture/Humidity Resistance Moisture/humidity resistance Other Resistance Mechanical protection Conductivity
Dissipation Factor 0.00100 Test Method Dielectric Strength (V/mil) Durable, 625 Test Method Dielectric Constant 2.40 Test Method Volume Resistivity (O) 5.0 E15 (ohm*cm) Test Method Hardness
Stress Relief Low stress Shore A Hardness 10 Test Method Flexibility Soft Other Properties
Specific Gravity 0.980 Test Method % Solids (%) 100 Business Information
Shelf Life Details Storage conditions and shelf life (“Use by” date) are indicated on the product label., Shelf life is indicated by the “Use Before” date found on the product label. Shelf Life Type From date of manufacture Shelf Life (mon) 15 -
-
Best Practices for Dow Dowsil HC 2100 Coating
-
Curing
Time to cure is dependent on several variables including the method of application, film thickness, temperature and humidity. Tack-free time in the data table gives an indication of typical times until surface is dry enough to handle. Cure time for full cure are indications of time needed to develop full physical properties such as durometer, tensile strength or adhesion. These times, including full cure time, can be significantly improved by introducing mild heat of 60°C or less.
-
-
Comparable Materials for Dow Dowsil HC 2100 Coating
Spec Engine® Results
Closest Results from this Manufacturer
Popular Articles
Silicones in LED Lighting | Gluespec
Read ArticleElectronic Component Adhesives Guide
Read ArticleTesting the effectiveness of surface treatments
Read ArticleInfographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Cure Temperature Test Methods
Cure Temperature | Cure Time Test Method |
---|---|
25°C Room Temperature | 50% RH, 0.3 mm, These values are not intended for use in preparing specifications. |
Cure Time Test Methods
Cure Time | Test Method |
---|---|
30 min | 50% RH, 0.3 mm, These values are not intended for use in preparing specifications. |
4,320 min |
Tack Free Time Test Methods
Tack Free Time | Tack Free Temperature | Test Method |
---|---|---|
Fast | ||
10 min | 25°C | These values are not intended for use in preparing specifications. |
Viscosity Test Methods
Viscosity | Test Method |
---|---|
High | |
400 cPs | These values are not intended for use in preparing specifications. |
Low |
Work / Pot Time Test Methods
Work / Pot Time | Temperature |
---|---|
>86,400 min | <29°C |
Dielectric Constant Test Methods
Dielectric Constant | Test Method |
---|---|
2.40 | 1 MHz |
Dielectric Strength Test Methods
Dielectric Strength | Test Method |
---|---|
Durable | |
625 V/mil | JIS K 6249, These values are not intended for use in preparing specifications. |
Dissipation Factor Test Methods
Dissipation Factor | Test Method |
---|---|
0.00100 | @ 1MHz (JIS K 6249), These values are not intended for use in preparing specifications. |
Volume Resistivity Test Methods
Volume Resistivity | Test Method |
---|---|
5.0 E15 (ohm*cm) | These values are not intended for use in preparing specifications. |
Shore A Hardness Test Methods
Shore A Hardness | Shore Hardness Test Method |
---|---|
10 | These values are not intended for use in preparing specifications. |
Specific Gravity Test Methods
Specific Gravity | Test Method |
---|---|
0.980 | Cured, These values are not intended for use in preparing specifications. |