Panacol Vitralit 4735 HC

Panacol Vitralit 4735 HC Datasheet
  • Description for Panacol Vitralit 4735 HC

    Panacol Vitralit 4735 HC is a 1 Part Heat cure Modified acrylate Liquid used to Laminate PMMA, Dry surface and Plastic

    *See Terms of Use Below

    Brand Vitralit
    Application Type Laminate, Potting, Bond
    1 Part or 2 Part 1 Part
    Material Form Liquid
    Substrate PMMA, Plastic, Glass/Al, Glass/PC, Al/PC, Polypropylene, Polyethylene, Low surface energy, Glass, Al/PC, Glass/Al, Glass/PC
    Industry Display, PCB’s
    Manufacturer Panacol
    Chemistry Modified acrylate, Solvent-free, Free of PFOS, Free of heavy metals, Free of Phthalates
    Cure Method Heat cure, UV / Visible light cure
    Cure Temperature (°C) 105
    Cure Time (min) 0.08, 0.03, 0.03, 30, >720
    Viscosity (cPs) 700 to 1,000
    Color Transparent
    High Temperature Resistance (°C) 120
    Low Temperature Resistance (°C) -40
    Light Refractive Index (RI) 1.47 – 1.48 nD20
    Density (g/cm³) 1.000 to 1.200
    Key Specifications Conform to the current EU-Directive RoHS.
  • Technical Data for Panacol Vitralit 4735 HC

    Overview
    • Application Type
    • 1 Part or 2 Part
      • 1 Part or 2 Part - 1 Part
    • Material Form
      • Liquid
    • Substrate
    • Industry
      • Displays - Display
      • Printed Circuit Board (PCB) - PCB’s
      • Medical - Medical devices
      • Other - Foil laminating
    • Chemistry
      • Acrylic - Modified acrylate
      • Solvent-Free
      • Metal-Free - Free of heavy metals
      • Other - Free of Phthalates, Free of PFOS
    • Cure Method
      • UV / Visible Light - UV / Visible light cure
      • Heat - Heat cure
    • Color
      • Clear / Transparent - Transparent
    • Key Specifications
      • RoHS (Restriction of Hazardous Substances) - Conform to the current EU-Directive RoHS.
    • Brand
      • Vitralit
    Specifications
    Cure Specs
    Cure Temperature (°C) 105 Test Method
    Cure Time (min) 0.08, 0.03, 0.03, 30, >720 Test Method
    Viscosity (cPs) 700 to 1,000 Test Method
    Linear Shrinkage (%) <3.00 Test Method
    Work / Pot Time (min) 10,080 Test Method
    Bond Strength
    General Bond Strength (psi) Excellent
    Shear Strength (psi) 3-7 MPa, 2-5 MPa, 2-5 MPa Test Method
    Tear Strength (piw) Tearproof
    Tensile Strength (psi) <2 MPa Test Method
    Material Resistance
    High Temperature Resistance (°C) 120 Test Method
    Low Temperature Resistance (°C) -40 Test Method
    Hardness
    Shore D Hardness 20 to 40 Test Method
    Elongation (%) 240 to 340 Test Method
    Flexibility Flexible
    Modulus (psi) 5-15 MPa Test Method
    Other Properties
    Light Refractive Index (RI) 1.47 – 1.48 nD20 Test Method
    Glass Transition Temp (Tg) (°C) 30 to 40 Test Method
    Coefficient of Thermal Expansion (CTE) <40 ppm/K, 300-500 ppm/K Test Method
    Flash Point (°F) >212.0 Test Method
    Density (g/cm³) 1.000 to 1.200 Test Method
    Business Information
    Shelf Life Details Syringe/Cartridge, Other packages, Transport At room temperature max. 25°C, At delivery, Store in original, unopened containers!, This is light sensitive material. Containers must remain covered when not in use. Minimize exposure of uncured material to daylight, artificial light, and UV light during storage and handling. Store uncured product in its original, closed container in a dry location. Any material removed from the original container must not be returned to the container as it could be contaminated. Panacol cannot assume responsibility for products that were improperly stored, contaminated, or repackaged into other containers.
    Shelf Life Temperature (°F) 32 to 50
    Shelf Life (mon) 6 to 12
  • Best Practices

    Best Practices information currently not available.
  • Comparable Materials for Panacol Vitralit 4735 HC

    *See Terms of Use Below

    Spec Engine® Results

Questions about this material?

Get personal assistance with your specific application needs.

Your Profile Edit
  1. 436d9baf-1a86-40f0-be9b-f524f6e2880a
  2. 436d9baf-1a86-40f0-be9b-f524f6e2880a

Popular Articles

Testing the effectiveness of surface treatments

Read Article

What Projects Require Custom Adhesive Formulations and Why?

Read Article

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

An Overview of Fluid Dispensing Systems & How They’re Used

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article
Information provided by Gluespec

Why Register?

  • View Technical Details
  • View Test Methods
  • View Key Specifications
  • View Similar Materials
  • Save your Project Searches

Already registered? Sign in.

Questions? Learn more about Gluespec

Gluespec Poll

Which answer best describes a project you are currently working on?
Cure Time Test Methods
Cure Time Test Method
0.08 min UV-curing (Hoenle Discharge lamp, 320-390nm), Intensity [mW/cm²] 60, measured by Hoenle UV-Meter 3.0 / UV-A F0, Layer thickness [mm] 0.05.
0.03 min LED-curing (Hoenle LED Spot 100, 365nm), Intensity [mW/cm²] 300, measured by Hoenle UV-Meter 3.0 / LED F2, Layer thickness [mm] 0.2
0.03 min LED-curing (Hoenle LED Spot 100, 405nm), Intensity [mW/cm²] 500, Measured by Hoenle UV-Meter 3.0 / LED F2, Layer thickness [mm] 0.2
30 min Secondary heat cure
>720 min Final strength
Cure Temperature Test Methods
Cure Temperature Cure Time Test Method
105°C Secondary heat cure
Viscosity Test Methods
Viscosity Test Method Temperature
700 to 1,000 cPs Brookfield LVT, Sp. 3/30 rpm, PE-Norm 001, Uncured 25°C
Linear Shrinkage Test Methods
Linear Shrinkage Test Method
<3.00 % PE-Norm 031, Cured
Work / Pot Time Test Methods
Work / Pot Time Test Method Temperature
10,080 min Uncured 20 to 25°C Room temperature
Tensile Strength Test Methods
Tensile Strength Test Method
<2 MPa 60mW/cm², 30sec, Fe spectrum, PE-Norm 014, Cured
Shear Strength Test Methods
Shear Strength Type Cure Time Cure Temperature Substrate Test Method
3-7 MPa Lab shear strength 30 min 105°C Glass/PC 500mW/cm², 2sec, 405nm LED, PE-Norm 013, Cured
2-5 MPa Lab shear strength 30 min 105°C Glass/Al 500mW/cm², 2sec, 405nm LED, PE-Norm 013, Cured
2-5 MPa Lab shear strength 30 min 105°C Al/PC 500mW/cm², 2sec, 405nm LED, PE-Norm 013, Cured
High Temperature Resistance Test Methods
High Temperature Resistance Test Method
120°C Cured
Low Temperature Resistance Test Methods
Low Temperature Resistance Test Method
-40°C Cured
Shore D Hardness Test Methods
Shore D Hardness Shore Hardness Test Method
20 to 40 Cured, PE-Norm 006
Elongation Test Methods
Elongation Test Method
240 to 340 % At break, 60mW/cm², 30sec, Fe spectrum, PE-Norm 014, Cured
Modulus Test Methods
Modulus Test Method
5-15 MPa Young´s modulus – Tensile test, 60mW/cm², 30sec, Fe spectrum, PE-Norm 056, Cured
Light Refractive Index (RI) Test Methods
Light Refractive Index (RI) Test Method
1.47 – 1.48 nD20 PE-Norm 023, Uncured
Flash Point Test Methods
Flash Point Test Method
>100.0°C PE-Norm 050, Uncured
Density Test Methods
Density Test Method
1.000 to 1.200 g/cm³ Uncured, PE-Norm 004
Coefficient of Thermal Expansion (CTE) Test Methods
Coefficient of Thermal Expansion (CTE) CTE Test Method
<40 ppm/K Below Tg, PE-Norm 017, Cured
300-500 ppm/K Above Tg, PE-Norm 017, Cured
Glass Transition Temp (Tg) Test Methods
Glass Transition Temp (Tg) Glass Transition Temperature (Tg) Test Method
30 to 40°C PE-Norm 009, DSC, Cured