Shinetsu X-23-8033-1

Shinetsu X-23-8033-1 Datasheet
  • Description for Shinetsu X-23-8033-1

    Shinetsu X-23-8033-1 is a 1 Part Solvent Solvent diluted Grease used to Lubricate

    *See Terms of Use Below

    Application Type Thermal interface grease
    1 Part or 2 Part 1 Part
    Material Form Grease
    Industry Heat sinks requiring high thermal conductivity, Semiconductor elements requiring high thermal conductivity, CPUs, MPUs
    Manufacturer Shinetsu
    Chemistry Solvent diluted, 0.93%, Low Molecular Weight Siloxane Stripped
    Cure Method Solvent
    Viscosity (cPs) 70 (Pa·s)
    Color White
    High Temperature Resistance (°C) 10 (mm2·K/W), 200
    Low Temperature Resistance (°C) -40
    Density (g/cm³) 3.480

Questions about this material?

Get personal assistance with your specific application needs.

Your Profile Edit
  1. ad8dd37f-818d-4aee-954d-437891780fbe
  2. ad8dd37f-818d-4aee-954d-437891780fbe

Popular Articles

Lubricants In-Depth: Silicone Compounds

Read Article

Lubricants 101

Read Article

Testing the effectiveness of surface treatments

Read Article

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article
Information provided by Gluespec

Why Register?

  • View Technical Details
  • View Test Methods
  • View Key Specifications
  • View Similar Materials
  • Save your Project Searches

Already registered? Sign in.

Questions? Learn more about Gluespec

Gluespec Poll

Which answer best describes a project you are currently working on?
Viscosity Test Methods
Viscosity Test Method
70 (Pa·s) Values are not for specification purposes.
Low Temperature Resistance Test Methods
Low Temperature Resistance Test Method
-40°C Usable Temp., Values are not for specification purposes.
High Temperature Resistance Test Methods
High Temperature Resistance Test Method
10 (mm2·K/W) Thermal Resistance, Values are not for specification purposes.
200°C Usable Temp., Values are not for specification purposes.
Thermal Conductivity Test Methods
Thermal Conductivity Test Method
Superior
4.00 W/m°K Values are not for specification purposes.
Dielectric Strength Test Methods
Dielectric Strength Test Method
10 (kV/mm) Values are not for specification purposes.
Density Test Methods
Density Temperature Test Method
3.480 g/cm³ 23°C Values are not for specification purposes.