Description for Dow Dowsil 510 Fluid 100 cs
• Phenylmethyl polysiloxane • Heat resistance • High flash points • Low volatility • Radiation resistance • Silicone fluid • Hydraulic arrestors (snubbers) • Hydraulically actuated valves and instruments used in nuclear plants.Brand Dowsil Application Type Silicone fluid 1 Part or 2 Part 1 Part Material Form Fluid Substrate Metals, Silicone rubber Industry Construction of snubbers, Hydraulic arrestors (snubbers), Hydraulically actuated valves Manufacturer Dow Chemistry Phenylmethyl polysiloxane, Low volatility, Low flammability Viscosity (cPs) 100 (cs) Oxidation Resistance Excellent oxidation resistance High Temperature Resistance (°C) <232, Heat resistance Low Temperature Resistance (°C) -57 Other Resistance Radiation resistance, Excellent temperature resistance
Popular Articles
Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleElectrically Conductive Adhesives
Read Article6 objects held together by adhesives you probably can't live without
Read ArticleTesting the effectiveness of surface treatments
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Viscosity Test Methods
Viscosity | Temperature |
---|---|
100 (cs) | 25°C |
High Temperature Resistance Test Methods
High Temperature Resistance | Test Method |
---|---|
<232°C | High-temperature stability |
Heat resistance |
Other Resistance Test Methods
Other Resistance | Test Method |
---|---|
Radiation resistance | 1.7e8 (rads) |
Excellent temperature resistance |
Thermal Conductivity Test Methods
Thermal Conductivity | Temperature |
---|---|
0.00036 (g-Cal/cm2-sec-°C) | 50°C |
Modulus Test Methods
Modulus | Test Method |
---|---|
179000 | Bulk Modulus |
253000 | Bulk Modulus |
Flash Point Test Methods
Flash Point | Test Method |
---|---|
High | |
525.2°F | Minimum |
Specific Gravity Test Methods
Specific Gravity | Temperature |
---|---|
0.992 | 25°C |