Description for Dow Sylgard Q3-3600 Thermally ConDuctive Encapsulant
Two-part; rapid heat cure; long pot life; excellent flow; self-priming.Brand Sylgard Chemical Resistance Good Application Type Encapsulate 1 Part or 2 Part 2-Part Material Form Liquid Substrate Ceramics, Metals, Filled plastics, Epoxy laminate boards Industry Electronic, Automotive applications, Sensors, High voltage transformers, Smart Meters, E-Mobility Solutions, Smart Home Devices, Heat sinks Manufacturer Dow Chemistry Silicone Cure Method 2-Part Cure, Versatile heat cure Cure Temperature (°C) 100, 150, 150 Cure Time (min) Rapid, 60, 60, 30 Viscosity (cPs) 3,200, Highly Flowable, Self-leveling, Low Color Gray Ozone Resistance Ozone resistance High Temperature Resistance (°C) 200 Low Temperature Resistance (°C) -45, -55 Volume Resistivity (O) 1E+13 (ohms/cm) Key Specifications UL (Underwriters Laboratory), ULC (Underwriters Laboratories of Canada), NFPA (National Fire Protection Association): UL 94: UL 94 V-1 -
Technical Data for Dow Sylgard Q3-3600 Thermally ConDuctive Encapsulant
Overview
-
Chemical Resistance
- Chemical Resistance - Good
-
Application Type
- Pottant / Encapsulant - Encapsulate
-
1 Part or 2 Part
- 2-Part
-
Material Form
- Liquid
-
Industry
- Smart Meters
- Smart Home Devices
- Automotive - Automotive applications
- E-Mobility Solutions
- Electronics - Electronic, Heat sinks
- Sensors
- Transformers - High voltage transformers
- Industrial - Industrial applications
-
Chemistry
-
Application Method
- Dispenser - Automated, Manual dispensing
-
Cure Method
- Heat - Versatile heat cure
- 2-Part Cure
-
Color
- Gray
-
Key Specifications
- UL (Underwriters Laboratory), ULC (Underwriters Laboratories of Canada), NFPA (National Fire Protection Association) : UL 94 : V-1 - UL 94 V-1
-
Brand
- Sylgard
Specifications
Cure Specs
Cure Temperature (°C) 100, 150, 150 Test Method Cure Time (min) Rapid, 60, 60, 30 Test Method Viscosity (cPs) 3,200, Highly Flowable, Self-leveling, Low Work / Pot Time (min) Long, 1,440, Good Test Method Thixotropic Excellent Mix Ratio 1:1 (by volume) Bond Strength
Tensile Strength (psi) 957 Material Resistance
Flame Resistance Flame resistance Ozone Resistance Ozone resistance UV Resistance UV resistance Environmental Resistance Environmental resistance High Temperature Resistance (°C) 200 Low Temperature Resistance (°C) -45, -55 Moisture/Humidity Resistance Moisture/humidity resistance Conductivity
Dielectric Strength (V/mil) Durable, 660 Thermal Conductivity (W/m°K) 0.80 Test Method Volume Resistivity (O) 1E+13 (ohms/cm) Hardness
Shore A Hardness 89 Test Method Elongation (%) 55 Flexibility Flexible Other Properties
Specific Gravity 2.150 Test Method Business Information
Shelf Life Details Shelf life is indicated by the “Use By” date found on the product label. For best results, Dow Corning thermally conductive materials should be stored at or below the maximum specified storage temperature. Special precautions must be taken to prevent moisture from contacting these materials. Containers should be kept tightly closed and head or air space minimized. Partially filled containers should be purged with dry air or other gases, such as nitrogen. Any special storage and handling instructions will be printed on the product containers. Shelf Life Type From date of manufacture Shelf Life (mon) 12 Not Good For
Don't Use With non-reactive metal substrates, non-reactive plastic surfaces, Teflon, polyethylene, polypropylene. -
-
Best Practices for Dow Sylgard Q3-3600 Thermally ConDuctive Encapsulant
-
Surface Preparation
All surfaces should be thoroughly cleaned and/or degreased with solvents such as Dow Corning® brand OS Fluids, naphtha, mineral spirits, or methyl ethyl ketone (MEK). Light surface abrasion is recommended whenever possible, because it promotes good cleaning and increases the surface area for bonding. A final surface wipe with acetone or IPA is also useful to remove residues that may be left behind by other cleaning methods. On some surfaces, different cleaning techniques will give better results than others. Users should determine the best techniques for their applications.
-
Mixing
Upon standing, some filler may settle to the bottom of the liquid after several weeks. To ensure a uniform product mix, the material in each container should be thoroughly mixed prior to use. Two-part materials should be mixed in the proper ratio either by weight or volume. The presence of light-colored streaks or marbling indicates inadequate mixing.
-
Deairing/Degassing
Automated airless dispense equipment can be used to reduce or avoid the need to de-air. If de-airing is required to reduce voids in the cured elastomer, consider a vacuum de-air schedule of >28 inches Hg (or a residual pressure of 10-20 mm of Hg) for 10 minutes or until bubbling subsides.
-
Curing
The one-part moisture-cure adhesives are generally cured at room temperature and in a range of 20 to 80 percent relative humidity. Greater than 90 percent of their full physical properties should be attained within 24 to 72 hours depending on the product chosen. These materials are not typically used for highly confined or deep section cures. Materials will generally cure about 0.25 inch (6.35 mm) per 7 days. Addition-cure adhesives should be cured at 100ºC (212ºF) or above. The cure rate is rapidly accelerated with heat (see heat-cure times in Typical Properties table). Thin sections of less than 2 mils may be cured in 15 minutes at 150ºC (302ºF). For thicker sections, a pre-cure at 70ºC (158ºF) may be necessary to reduce voids in the elastomer. Length of pre-cure will depend on section thickness and confinement of adhesive. It is recommended that 30 minutes at 70ºC (158ºF) be used as a starting point for determining necessary pre-cure time. Addition-curing materials contain all the ingredients needed for cure with no by-products from the cure mechanism. Deep-section or confined cures are possible. Cure progresses evenly throughout the material. These adhesives generally have long working times.
-
Testing
Due to the wide variety of substrate types and differences in substrate surface conditions, general statements on adhesion and bond strength are impossible. To ensure maximum bond strength for elastomers and adhesives on a particular substrate, 100 percent cohesive failure of the adhesive in a lap shear or similar adhesive strength is needed. This ensures compatibility of the adhesive with the substrate being considered. Also, this test can be used to determine minimum cure time or to detect the presence of surface contaminants such as mold release agents, oils, greases and oxide films.
-
-
Comparable Materials for Dow Sylgard Q3-3600 Thermally ConDuctive Encapsulant
Spec Engine® Results
Popular Articles
Testing the effectiveness of surface treatments
Read Article6 objects held together by adhesives you probably can't live without
Read ArticleElectrically Conductive Adhesives
Read ArticleInfographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Cure Temperature Test Methods
Cure Temperature | Cure Time Test Method |
---|---|
100°C | Time to 90 percent of final hardness and adhesion or 90 percent of curve height for elastic modulus; additional time may be required for the part to warm to near oven temperature |
150°C | Time to 90 percent of final hardness and adhesion or 90 percent of curve height for elastic modulus, additional time may be required for the part to warm to near oven temperature. |
150°C | Time to 90 percent of final hardness and adhesion or 90 percent of curve height for elastic modulus, additional time may be required for the part to warm to near oven temperature. |
Cure Time Test Methods
Cure Time | Test Method |
---|---|
Rapid | |
60 min | Time to 90 percent of final hardness and adhesion or 90 percent of curve height for elastic modulus; additional time may be required for the part to warm to near oven temperature |
60 min | Time to 90 percent of final hardness and adhesion or 90 percent of curve height for elastic modulus, additional time may be required for the part to warm to near oven temperature. |
30 min | Time to 90 percent of final hardness and adhesion or 90 percent of curve height for elastic modulus, additional time may be required for the part to warm to near oven temperature. |
Work / Pot Time Test Methods
Work / Pot Time | Test Method | Temperature |
---|---|---|
Long | Room temperature | |
1,440 min | Working time | 25°C |
Good | Working time |
Thermal Conductivity Test Methods
Thermal Conductivity | Temperature |
---|---|
0.80 W/m°K | 25°C |
Shore A Hardness Test Methods
Shore A Hardness | Shore Hardness Test Method |
---|---|
89 | Durometer |
Specific Gravity Test Methods
Specific Gravity | Test Method |
---|---|
2.150 | Cured |

1 VIEW FREE
Don't Leave!