Description for Dymax Ultra Light-Weld 9008
A general purpose product for encapsulating and sealing electronic components in chip-on-Board or Chip-on-Flex (COF) applications. Forms flexible, highly moisture resistant bonds to diverse surfaces such as polyimide (Kapton®), DAP, glass, epoxy board, metal and PET.Brand Ultra Light-weld Application Type Encapsulate 1 Part or 2 Part 1-Part Material Form Liquid Substrate Ceramic, Glass, Metal, Polyimide, PET, Epoxy board Industry Chip on Flex, Camera Module, E-Mobility Solutions, Battery Systems, Avionics, Wire Bonding, Bare die, Chip on Board Manufacturer Dymax Chemistry Acrylated Urethane, No Nonreactive Solvents, Acrylated Urethane, Acrylated Urethane Cure Method UV/Visible Light Cure Cure Time (min) 0.08 Viscosity (cPs) 4,500 Color Clear, Light Straw, Lt. Yellow High Temperature Resistance (°C) 177 Low Temperature Resistance (°C) -55 Volume Resistivity (O) 1.80E+13 ohm-cm Light Refractive Index (RI) 1.5000 Density (g/cm³) 1.03 g/ml Key Specifications In full compliance with RoHS Directives 2002/95/EC; In full compliance with RoHS Directives 2003/11/EC -
Technical Data for Dymax Ultra Light-Weld 9008
Overview
-
Application Type
- Pottant / Encapsulant - Encapsulate
-
1 Part or 2 Part
- 1-Part
-
Material Form
- Liquid
-
Industry
- Cameras - Camera Module
- Wirebond - Wire Bonding
- Bare die
- Chip-on-Board (COB) - Chip on Board
- E-Mobility Solutions
- Avionics
- Electronics - Chip on Flex
- Battery Systems
- Other - Ideal for COF Applications
-
Chemistry
- Acrylated Urethane
- Acrylic - Acrylated Urethane
- Solvent-Free - No Nonreactive Solvents
- Polyurethane - Acrylated Urethane
-
Cure Method
- UV / Visible Light - UV/Visible Light Cure
-
Color
- Clear / Transparent - Clear, Lt. Yellow
- Yellow - Light Straw
-
Key Specifications
- RoHS (Restriction of Hazardous Substances) - In full compliance with RoHS Directives 2002/95/EC; In full compliance with RoHS Directives 2003/11/EC
-
Brand
- Ultra Light-weld
Specifications
Cure Specs
Cure Time (min) 0.08 Test Method Viscosity (cPs) 4,500 Test Method Fixture or Handling Strength Time (min) 0.02, 0.02, 0.03, 0.03, 0.03, 8.2 m/min, 8.2 m/min Test Method Linear Shrinkage (%) 1.20 Test Method Bond Strength
Tensile Strength (psi) 900, 1,500 Test Method Material Resistance
High Temperature Resistance (°C) 177 Low Temperature Resistance (°C) -55 Moisture/Humidity Resistance Moisture resistance, Moisture Resistant Bonds Conductivity
Dissipation Factor 0.06000 Test Method Dielectric Strength (V/mil) 0.01 Test Method Dielectric Constant 5.07 Test Method Surface Resistivity (O) 2.90E+14 ohm Test Method Volume Resistivity (O) 1.80E+13 ohm-cm Test Method Hardness
Shore A Hardness 85 Test Method Shore D Hardness 35 Test Method Elongation (%) 300, 270 Test Method Flexibility Flexible, Flexible Modulus (psi) 6,500 Test Method Other Properties
Glass Transition Temp (Tg) (°C) 55 Test Method Light Refractive Index (RI) 1.5000 Test Method Coefficient of Thermal Expansion (CTE) 131 µm/m/°C, 230 µm/m/°C Test Method Flash Point (°F) >199.4 Test Method Density (g/cm³) 1.03 g/ml Test Method Business Information
Shelf Life Details Store the material in a cool, dark place when not in use. Do not expose to light. This product may polymerize upon prolonged exposure to ambient and artificial light. Keep covered when not in use. This material has a minimum 12-month shelf life from date of shipment, unless otherwise specified, when stored between 10 C [50 F] and 32 C [90 F] in the original, unopened container. Shelf Life Temperature (°F) 50 to 90 Shelf Life Type From date of shipment Shelf Life (mon) 12 -
-
Best Practices for Dymax Ultra Light-Weld 9008
-
Surface Preparation
All surfaces in contact with the material should be clean and free from flux residue, grease, mold release, or other contaminants prior to dispensing the material.
-
Curing
Full cure is best determined empirically by curing at different times and intensities, and measuring the corresponding change in cured properties such as tackiness, adhesion, hardness, etc. Full cure is defined as the point at which more light exposure no longer improves cured properties. Higher intensities or longer cures (up to 5x) generally will not degrade Dymax light-curable materials.
This product cures with exposure to UV and visible light. Exposure to ambient and artificial light should be kept to a minimum before curing. Dispensing components including needles and fluid lines should be 100% light blocking, not just UV blocking.
Cure speed is dependent upon many variables, including lamp intensity, distance from the light source, required depth of cure, thickness, and percent light transmission of components between the material and light source.
Oxygen in the atmosphere may inhibit surface cure. Surfaces exposed to air may require high-intensity (>100 mW/cm2) UV light to produce a dry surface cure. Flooding the curing area with an inert gas, such as nitrogen, can also reduce the effects of oxygen inhibition.
Parts should be allowed to cool after cure before testing and subjecting to any loads or electrical testing.
Light curing generally produces some heat. If necessary, cooling fans can be placed in the curing area to reduce the heating effect on components.
At the point of curing, an air exhaust system is recommended to dissipate any heat and vapors formed during the curing process.
-
Clean-Up
Uncured material may be removed from dispensing components and parts with organic solvents. Cured material will be impervious to many solvents and difficult to remove. Cleanup of cured material may require mechanical methods of removal.
-
Troubleshooting
In rare cases, stress cracking may occur in assembled parts. Three options may be explored to eliminate this problem. One option is to heat anneal the parts to remove molded-in stresses. A second option is to open any gap between mating parts to reduce stress caused by an interference fit. The third option is to minimize the amount of time the liquid material remains in contact with the substrate(s) prior to curing.
-
-
Comparable Materials for Dymax Ultra Light-Weld 9008
Spec Engine® Results
Popular Articles
Testing the effectiveness of surface treatments
Read ArticleInstant Adhesives Guide
Read ArticleInfographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleElectronic Component Adhesives Guide
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Cure Time Test Methods
Cure Time | Test Method |
---|---|
0.08 min | Using 365 nanometer UV light, (0.25 inches) |
Fixture or Handling Strength Time Test Methods
Fixture or Handling Strength Time | Fixture-Handling Strength Test Method |
---|---|
0.02 min | 2000-EC (50 mW/cm2); Intensity was measured over the UVA range (320-395 nm) using a Dymax ACCU-CAL™ 50 Radiometer.; Curing through light-blocking substrates may require longer cure times if they obstruct wavelengths used for light curing (320-400 nm for UV light curing, 320-450 nm for UV/Visible light curing). These fixture times/belt speeds are typical for curing thin films through 100% light-transmitting substrates. |
0.02 min | 5000-EC (200 mW/cm2); Intensity was measured over the UVA range (320-395 nm) using a Dymax ACCU-CAL™ 50 Radiometer.; Curing through light-blocking substrates may require longer cure times if they obstruct wavelengths used for light curing (320-400 nm for UV light curing, 320-450 nm for UV/Visible light curing). These fixture times/belt speeds are typical for curing thin films through 100% light-transmitting substrates. |
0.03 min | BlueWave® LED Prime UVA (10 W/cm2); Intensity was measured over the UVA/Visible range (350-450 nm) using a Dymax ACCU-CAL™ 50-LED Radiometer.; Curing through light-blocking substrates may require longer cure times if they obstruct wavelengths used for light curing (320-400 nm for UV light curing, 320-450 nm for UV/Visible light curing). These fixture times/belt speeds are typical for curing thin films through 100% light-transmitting substrates. |
0.03 min | BlueWave® 75 (5.0 W/cm2); Intensity was measured over the UVA range (320-395 nm) using a Dymax ACCU-CAL™ 50 Radiometer.; Curing through light-blocking substrates may require longer cure times if they obstruct wavelengths used for light curing (320-400 nm for UV light curing, 320-450 nm for UV/Visible light curing). These fixture times/belt speeds are typical for curing thin films through 100% light-transmitting substrates. |
0.03 min | BlueWave® 200 (10 W/cm2); Intensity was measured over the UVA range (320-395 nm) using a Dymax ACCU-CAL™ 50 Radiometer.; Curing through light-blocking substrates may require longer cure times if they obstruct wavelengths used for light curing (320-400 nm for UV light curing, 320-450 nm for UV/Visible light curing). These fixture times/belt speeds are typical for curing thin films through 100% light-transmitting substrates. |
8.2 m/min | UVCS Conveyor with one 5000-EC (200 mW/cm2); At 53 mm [2.1 in] focal distance. Maximum speed of conveyor is 8.2 m/min [27 ft/min]. Intensity was measured over the UVA range (320-395 nm) using the Dymax ACCU-CAL™ 150 Radiometer.; Curing through light-blocking substrates may require longer cure times if they obstruct wavelengths used for light curing (320-400 nm for UV light curing, 320-450 nm for UV/Visible light curing). These fixture times/belt speeds are typical for curing thin films through 100% light-transmitting substrates. |
8.2 m/min | UVCS Conveyor with Fusion F300S (2.5 W/cm2); At 53 mm [2.1 in] focal distance. Maximum speed of conveyor is 8.2 m/min [27 ft/min]. Intensity was measured over the UVA range (320-395 nm) using the Dymax ACCU-CAL™ 150 Radiometer.; Curing through light-blocking substrates may require longer cure times if they obstruct wavelengths used for light curing (320-400 nm for UV light curing, 320-450 nm for UV/Visible light curing). These fixture times/belt speeds are typical for curing thin films through 100% light-transmitting substrates. |
Linear Shrinkage Test Methods
Linear Shrinkage | Test Method |
---|---|
1.20 % | ASTM D-2556 |
Viscosity Test Methods
Viscosity | Test Method |
---|---|
4,500 cPs | ASTM D-2556, (nominal) |
Tensile Strength Test Methods
Tensile Strength | Test Method |
---|---|
900 psi | ASTM D-638, at Break |
1,500 psi | at Break; ASTM D638; Cured |
Dielectric Constant Test Methods
Dielectric Constant | Test Method |
---|---|
5.07 | 1 MHz; ASTM D1304-99 |
Dielectric Strength Test Methods
Dielectric Strength | Test Method |
---|---|
0.01 V/mil | Dielectric Breakdown Voltage; MIL-I-46058C |
Dissipation Factor Test Methods
Dissipation Factor | Test Method |
---|---|
0.06000 | 1 MHz; ASTM D1304-99 |
Surface Resistivity Test Methods
Surface Resistivity | Test Method |
---|---|
2.90E+14 ohm | ASTM D1304-99 |
Volume Resistivity Test Methods
Volume Resistivity | Test Method |
---|---|
1.80E+13 ohm-cm | ASTM D1304-99 |
Elongation Test Methods
Elongation | Test Method |
---|---|
300 % | at Break; ASTM D-638 |
270 % | at Break; ASTM D638; Cured |
Modulus Test Methods
Modulus | Test Method |
---|---|
6,500 psi | Modulus of Elasticity; ASTM D638; Cured |
Shore A Hardness Test Methods
Shore A Hardness | Shore Hardness Test Method |
---|---|
85 | ASTM D-2240 |
Shore D Hardness Test Methods
Shore D Hardness | Shore Hardness Test Method |
---|---|
35 | ASTM D-2240 |
Coefficient of Thermal Expansion (CTE) Test Methods
Coefficient of Thermal Expansion (CTE) | CTE Test Method |
---|---|
131 µm/m/°C | DSTM 610; a1; Cured |
230 µm/m/°C | DSTM 610; a2; Cured |
Density Test Methods
Density | Test Method |
---|---|
1.03 g/ml | ASTM D1875 |
Flash Point Test Methods
Flash Point | Test Method |
---|---|
>93.0°C | Uncured |
Glass Transition Temp (Tg) Test Methods
Glass Transition Temp (Tg) | Glass Transition Temperature (Tg) Test Method |
---|---|
55°C | DSTM 256; Cured |
Light Refractive Index (RI) Test Methods
Light Refractive Index (RI) | Temperature | Test Method |
---|---|---|
1.5000 | 20°C | ASTM D542; Cured |