Elantas (Altana) Conap PR-1167 Datasheet Elantas (Altana) Conap PR-1167

Information provided by Gluespec
  • Description for Elantas (Altana) Conap PR-1167

    A solvent-borne, polyurethane, isocyanate prepolymer-based primer, excellent adhesion to neoprene rubber, curable at elevated or ambient temperature.

    *See Terms of Use Below

    Brand Cytec, Conap
    Application Type Primer
    1 Part or 2 Part 1-Part
    Material Form Liquid
    Substrate Neoprene rubber, Polyurethane, Rubber, Cadmium-plated metals
    Manufacturer Elantas (Altana)
    Chemistry Solvent- based, Polyurethane, Isocyanate prepolymer, Solvent-borne
    Cure Method Atmospheric humidity, Elevated temperature, Room temperature cure, Moisture, Ambient temperature, Air dry
    Viscosity (cPs) 75
    Color Light Amber
    Key Specifications Complies with Directive 2011/65/EU, Mil-Spec (United States Military Standard): QPL Listed for MIL-M-24041C, Category A, Type I, Mil-Spec (United States Military Standard): QPL Listed for MIL-M-24041C, Category B, Type I
    Can Be Used In Conjunction With These Materials Urethane
  • Technical Data for Elantas (Altana) Conap PR-1167

    Overview
    • Application Type
    • 1 Part or 2 Part
      • 1-Part
    • Material Form
      • Liquid
    • Substrate
    • Industry
      • Other - Bonding liquid polyurethane potting compounds, Bonding liquid polyurethane molding compounds
    • Chemistry
    • Application Method
      • Brush
      • Spray
      • Dip
    • Cure Method
      • Room Temperature / Air Dry - Room temperature cure, Air dry
      • Moisture / Condensation Cure - Atmospheric humidity, Moisture
      • Heat - Elevated temperature, Ambient temperature
    • Color
      • Red - Light Amber
    • Key Specifications
      • RoHS (Restriction of Hazardous Substances) - Complies with Directive 2011/65/EU
      • Mil-Spec (United States Military Standard) : M-24041C - QPL Listed for MIL-M-24041C, Category B, Type I, QPL Listed for MIL-M-24041C, Category A, Type I
    • Can Be Used In Conjunction With These Materials
      • Urethanes - Urethane
    • Brand
      • Conap
      • Cytec
    Specifications
    Cure Specs
    Viscosity (cPs) 75 Test Method
    Dry Time (min) 60 to 120
    Bond Strength
    General Bond Strength (psi) Excellent
    Other Properties
    Specific Gravity 1.020 Test Method
    Flash Point (°F) 80.6 Test Method
    % Solids (%) 58 Test Method
    Business Information
    Shelf Life Details CONAP PR-1167 has a minimum shelf life of 15 months from date of manufacture., Store at or below 25°C / 77°F in a dry controlled environment out of direct sunlight. This material should be suitable for use stored under these conditions in the original sealed containers for twelve (12) months from the date of shipment.
    Shelf Life Temperature (°F) <77
    Shelf Life Type From date of manufacture, From the date of shipment
    Shelf Life (mon) 15, 12
  • Best Practices for Elantas (Altana) Conap PR-1167

    *See Terms of Use Below

    1. Surface Preparation

      Cleanliness of the substrate is a major factor in promoting adhesion and preventing under-film corrosion. Assemblies must be clean, oil-free and dry.

    2. Application

      Performance of the CONAP® PR-1167 cured film is dependent on process controls used in application of the coating.

      PR-1167 can be applied by spraying, dipping or brushing. If additional viscosity reduction is desired, dilutions of the PR-1167 can be done with CONAP® S-13 Solvent for most applications.

      A smooth, uniform coat of PR-1167 should be applied and allowed to air dry for 1 – 2 hours or until tack-free.

    3. Curing

      Curable at elevated or ambient temperature

      The cure schedules are based on time after the unit reaches the specified temperature and are recommendations only. The user is responsible for determining the optimum cure conditions for his application.

  • Comparable Materials for Elantas (Altana) Conap PR-1167

    *See Terms of Use Below

    Spec Engine® Results

    Closest Results from this Manufacturer

Popular Articles

What are the Types of Adhesive Sealants? An In-Depth Q&A

Read Article

Primers and Surface Preparation for Proper Adhesive Wetting & Bonding - Q&A

Read Article

Testing the effectiveness of surface treatments

Read Article

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article

Featured Ads

Top Catalog Pages for Elantas (Altana) Conap PR-1167

Gluespec Poll

When you're researching or sourcing materials online, what device are you using?
Viscosity Test Methods
Viscosity Test Method Temperature
75 cPs Supplied, The above properties are typical values and are not intended for specification use. 25°C
Flash Point Test Methods
Flash Point Test Method
27.0°C ASTM D93, Supplied,The above properties are typical values and are not intended for specification use.
% Solids Test Methods
% Solids Test Method
58 % 135°C for 45 min, Supplied, The above properties are typical values and are not intended for specification use.
Specific Gravity Test Methods
Specific Gravity Temperature Test Method
1.020 25°C Supplied,The above properties are typical values and are not intended for specification use.