Description for Dow Dowsil SC 102 Compound
• One part • White • Non-curing • Non-flowing thermally conductive compoundChemical Resistance Good Application Type Seal 1 Part or 2 Part 1-Part Material Form Paste Industry Electronic heat sources, Automotive applications, Heat sink, PCB system assembly modules, Computer, Smart Meters, E-Mobility Solutions, Chassis, Smart Home Devices, Electronics, Heat sinks, Electrical device Manufacturer Dow Chemistry Silicone, Non Volatile Content : 99.7 % Application Method Spatula Cure Temperature (°C) 20 to 25 Viscosity (cPs) Non-flowing, 29,000 Color White Ozone Resistance Ozone resistance High Temperature Resistance (°C) 200 Low Temperature Resistance (°C) -45, -55, Low thermal resistance Volume Resistivity (O) 2E+16 (Ohm-cm) -
Technical Data for Dow Dowsil SC 102 Compound
Overview
-
Chemical Resistance
- Chemical Resistance - Good
-
Application Type
- Sealant - Seal
-
1 Part or 2 Part
- 1-Part
-
Material Form
- Paste
-
Industry
- Storage & Graphics - Computer
- Smart Meters
- Smart Home Devices
- Automotive - Automotive applications
- E-Mobility Solutions
- Chassis
- Electronics - Electronic heat sources, Heat sinks, Electrical device
- Heat sink
- Printed Circuit Board (PCB) - PCB system assembly modules
- Power Supplies - Power supply
- Industrial - Gap fill
-
Chemistry
- VOC-free - Non Volatile Content : 99.7 %
- Silicone
-
Application Method
- Dispenser - Automated, Manual dispensing
- Spatula/Trowel - Spatula
- Screen Print - Screen, Stencil
-
Cure Method
- None - Non-curing
-
Color
- White
Specifications
Cure Specs
Cure Temperature (°C) 20 to 25 Viscosity (cPs) Non-flowing, 29,000 Test Method Material Resistance
Ozone Resistance Ozone resistance UV Resistance UV resistance High Temperature Resistance (°C) 200 Low Temperature Resistance (°C) -45, -55, Low thermal resistance Conductivity
Dissipation Factor 2E-02 Test Method Filler Heat-conductive metal oxides, Polydimethylsiloxane Dielectric Strength (V/mil) Durable, 50 Test Method Dielectric Constant 4.00 Test Method Thermal Conductivity (W/m°K) High, Moderate, 0.52 (BTU/hr-ft-°F), Thermally conductive Test Method Volume Resistivity (O) 2E+16 (Ohm-cm) Test Method Other Properties
Specific Gravity 2.400 Business Information
Shelf Life Details The product should be stored in its original packaging with the cover tightly attached to avoid any contamination. Store in accordance with any special instructions listed on the product label. The product should be used by the indicated Exp. Date found on the label. Shelf Life Type From date of manufacture Shelf Life (mon) 24 Not Good For
Don't Use With non-reactive metal substrates, non-reactive plastic surfaces, Teflon, polyethylene, polypropylene. -
-
Best Practices for Dow Dowsil SC 102 Compound
-
Surface Preparation
All surfaces should be thoroughly cleaned and/or degreased with solvents such as Dow Corning® brand OS Fluids, naphtha, mineral spirits, or methyl ethyl ketone (MEK). Light surface abrasion is recommended whenever possible, because it promotes good cleaning and increases the surface area for bonding. A final surface wipe with acetone or IPA is also useful to remove residues that may be left behind by other cleaning methods. On some surfaces, different cleaning techniques will give better results than others. Users should determine the best techniques for their applications.
-
Application
Apply grease with a squeegee through a stencil or screen
Apply grease with a squeegee through a stencil or screen
-
Curing
The one-part moisture-cure adhesives are generally cured at room temperature and in a range of 20 to 80 percent relative humidity. Greater than 90 percent of their full physical properties should be attained within 24 to 72 hours depending on the product chosen. These materials are not typically used for highly confined or deep section cures. Materials will generally cure about 0.25 inch (6.35 mm) per 7 days. Addition-cure adhesives should be cured at 100ºC (212ºF) or above. The cure rate is rapidly accelerated with heat (see heat-cure times in Typical Properties table). Thin sections of less than 2 mils may be cured in 15 minutes at 150ºC (302ºF). For thicker sections, a pre-cure at 70ºC (158ºF) may be necessary to reduce voids in the elastomer. Length of pre-cure will depend on section thickness and confinement of adhesive. It is recommended that 30 minutes at 70ºC (158ºF) be used as a starting point for determining necessary pre-cure time. Addition-curing materials contain all the ingredients needed for cure with no by-products from the cure mechanism. Deep-section or confined cures are possible. Cure progresses evenly throughout the material. These adhesives generally have long working times.
-
Testing
Due to the wide variety of substrate types and differences in substrate surface conditions, general statements on adhesion and bond strength are impossible. To ensure maximum bond strength for elastomers and adhesives on a particular substrate, 100 percent cohesive failure of the adhesive in a lap shear or similar adhesive strength is needed. This ensures compatibility of the adhesive with the substrate being considered. Also, this test can be used to determine minimum cure time or to detect the presence of surface contaminants such as mold release agents, oils, greases and oxide films.
-
-
Comparable Materials for Dow Dowsil SC 102 Compound
Spec Engine® Results
Closest Results from this Manufacturer
Popular Articles
Silicones in LED Lighting | Gluespec
Read ArticleWhat Are the Differences Between Adhesives and Sealants?
Read ArticleInfographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleTesting the effectiveness of surface treatments
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Viscosity Test Methods
Viscosity | Test Method |
---|---|
Non-flowing | |
29,000 cPs | These values are not intended for use in preparing specifications. |
Dielectric Constant Test Methods
Dielectric Constant | Test Method |
---|---|
4.00 | At 50 Hz, These values are not intended for use in preparing specifications. |
Dielectric Strength Test Methods
Dielectric Strength | Test Method |
---|---|
Durable | |
50 V/mil | These values are not intended for use in preparing specifications. |
Dissipation Factor Test Methods
Dissipation Factor | Test Method |
---|---|
2E-02 | At 50 Hz, These values are not intended for use in preparing specifications. |
Thermal Conductivity Test Methods
Thermal Conductivity | Test Method |
---|---|
High | |
Moderate | |
0.52 (BTU/hr-ft-°F) | These values are not intended for use in preparing specifications. |
Thermally conductive |
Volume Resistivity Test Methods
Volume Resistivity | Test Method |
---|---|