Description for Elantas (Altana) FP-1303
A two-component, unfilled, fast setting polyurethane sealant designed for use in Hepa and other air filtration devices. It is also used for potting, casting, embedding, and encapsulating of electronic circuits, components, and power devices.Note: This material has been discontinued. Please view the Comparable Materials tab or call us at (262) 293-7970 for additional help.
Brand Cytec Application Type Seal 1 Part or 2 Part 2-Part Material Form Liquid Industry electronic circuits, air filtration devices, components, power devices Manufacturer Elantas (Altana) Chemistry polyurethane Cure Method Resin/Hardener Cure Temperature (°C) 35, 25, 80 Cure Time (min) 10,080, 240 Viscosity (cPs) 1,100 Color Amber, White High Temperature Resistance (°C) 54 Low Temperature Resistance (°C) -54 Volume Resistivity (O) 7.2e14 (ohm-cm), 1.8e11 (ohm-cm) -
Technical Data for Elantas (Altana) FP-1303
Overview
-
Application Type
- Sealant - Seal
-
1 Part or 2 Part
- 2-Part
-
Material Form
- Liquid
-
Industry
- Electronics - electronic circuits, components, power devices
- Industrial - machine casting and rapid production.
- Filters - air filtration devices
- Other - Hepa
-
Chemistry
-
Application Method
- Other - hand processing
-
Cure Method
- 2-Part Cure - Resin/Hardener
-
Color
- Red - Amber
- White
-
Brand
- Cytec
Specifications
Cure Specs
Cure Temperature (°C) 35, 25, 80 Test Method Cure Time (min) 10,080, 240 Test Method Viscosity (cPs) 1,100 Test Method Set Time (min) Fast, 12 Test Method Work / Pot Time (min) 2.00 Test Method Mix Ratio 100:116 (by weight) Bond Strength
Tear Strength (piw) 119 (pli) Tensile Strength (psi) 2,000 Material Resistance
High Temperature Resistance (°C) 54 Low Temperature Resistance (°C) -54 Conductivity
Dissipation Factor 0.01700, 0.03000 Test Method Filler Unfilled Insulation Resistance (O) >2.5e13 (ohms), Insulation Resistance, 1.4e9 (ohms) Test Method Dielectric Strength (V/mil) 650 (vpm) Test Method Dielectric Constant 3.40, 6.10 Test Method Thermal Conductivity (W/m°K) 7.1e-4 (CAL/SEC/CM2/°C/CM) Surface Resistivity (O) >1.0e15 (ohms), 6.9e12 (ohms) Test Method Volume Resistivity (O) 7.2e14 (ohm-cm), 1.8e11 (ohm-cm) Test Method Hardness
Shore A Hardness 80 Elongation (%) 155 Other Properties
Specific Gravity 1.070 Test Method Business Information
Shelf Life Details The Part A and Part B components of these systems are storage stable in their original, unopened containers for 18 months from the date of manufacture when stored at 65-85°F. Shelf Life Temperature (°F) 149 to 185 Shelf Life Type From the date of manufacture Shelf Life (mon) 18 -
-
Best Practices for Elantas (Altana) FP-1303
-
Application
Pour into dry preheated units. Best results are generally obtained when the unit is at least 10°C warmer than the mixed material. Pour down the side of the unit to be potted to avoid air entrapment.
-
Mixing
Mix the two components together thoroughly at room temperature in metal, plastic, or glass containers, using a metal spatula. DO NOT use paper containers or wooden sticks. Any moisture introduced into the system will cause bubbling and/or foaming during curing.
-
Deairing/Degassing
If void-free castings are required for the particular application, degas the mixed system at 1-5mm of mercury vacuum. Allow froth to rise and collapse, continue vacuum for 2-5 minutes. Containers should generally have twice the volume of mixed material to allow for frothing.
-
Curing
If the potted device is to be heat cured, it is best to allow the device to sit at room temperature for 1-2 hours to permit air bubbles, entrapped during pouring, to dissipate.
-
-
Comparable Materials for Elantas (Altana) FP-1303
Spec Engine® Results
Closest Results from this Manufacturer
Popular Articles
What are the Types of Adhesive Sealants? An In-Depth Q&A
Read ArticleQ&A Tutorial on the Adhesive Sealant Selection Process
Read ArticleTesting the effectiveness of surface treatments
Read ArticleInfographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Cure Temperature Test Methods
Cure Temperature | Cure Time Test Method |
---|---|
35°C | 13 grams in 52°C oven |
25°C | |
80°C |
Cure Time Test Methods
Cure Time | Test Method |
---|---|
10,080 min | |
240 min |
Set Time Test Methods
Set Time | Set Temperature | Test Method |
---|---|---|
Fast | ||
12 min | 35°C | 13 grams in 52°C oven |
Viscosity Test Methods
Viscosity | Temperature |
---|---|
1,100 cPs | 35°C |
Work / Pot Time Test Methods
Work / Pot Time | Test Method | Temperature |
---|---|---|
2.00 min | Work Life @ 35°C - time to 100,000 cps | 35°C |
Dielectric Constant Test Methods
Dielectric Constant | Temperature | Test Method |
---|---|---|
3.40 | 25°C | Dielectric Constant @ 1 KHz |
6.10 | 105°C | Dielectric Constant @ 1 KHz |
Dielectric Strength Test Methods
Dielectric Strength | Test Method |
---|---|
650 (vpm) | (1/16) |
Dissipation Factor Test Methods
Dissipation Factor | Temperature | Test Method |
---|---|---|
0.01700 | 25°C | Dissipation Factor @ 1 KHz |
0.03000 | 25°C | Dissipation Factor @ 1 KHz |
Insulation Resistance Test Methods
Insulation Resistance | Temperature |
---|---|
>2.5e13 (ohms) | 25°C |
Insulation Resistance | 25°C |
1.4e9 (ohms) | 130°C |
Surface Resistivity Test Methods
Surface Resistivity | Temperature |
---|---|
>1.0e15 (ohms) | 25°C |
6.9e12 (ohms) | 130°C |
Volume Resistivity Test Methods
Volume Resistivity | Temp (°C) |
---|---|
7.2e14 (ohm-cm) | 25°C |
1.8e11 (ohm-cm) | 130°C |
Specific Gravity Test Methods
Specific Gravity | Temperature |
---|---|
1.070 | 25°C |