Henkel Technomelt 1942 Datasheet Henkel Technomelt 1942

Information provided by Gluespec
  • Description for Henkel Technomelt 1942

    EVA-based, medium setting, general purpose adhesive. It exhibits excellent adhesion to wood and many plastics such as; nylon, polycarbonate, PVC, polystyrene, ABS, and acrylic.

    *See Terms of Use Below

    Brand Technomelt, Loctite, Hysol
    Application Type Bond
    1 Part or 2 Part 1-Part
    Material Form Sticks
    Substrate Acrylic, Aluminum, Glass, Nylon, Plastics, Polycarbonate, Polypropylene, PVC, Grit-Blasted Steel, Wood, Stainless Steel, Zinc Dichromate, Polystyrene, HD Polyethylene, LDPE, Anodized Aluminum, Epoxy, Galvanized, Polyester (PBT), ABS, Valox, G-10 Epoxy, PBT
    Manufacturer Henkel
    Chemistry Hot melt: EVA
    Cure Method Hot melt
    Cure Temperature (°C) 22
    Cure Time (min) 7,200
    Viscosity (cPs) 5,000
    High Temperature Resistance (°C) 61
    Volume Resistivity (O) 2.8e16
    Key Specifications FDA (U.S. Food & Drug Administration) and/or CFIA (Canadian Food Inspection Agency): Listed under Food and Drug Administration CFR 175.105, Adhesives
  • Technical Data for Henkel Technomelt 1942

    Overview
    • Application Type
    • 1 Part or 2 Part
      • 1-Part
    • Material Form
      • Stick - Sticks
    • Substrate
    • Chemistry
      • Hot melt : EVA (Ethyl Vinyl Acetate) - EVA
    • Cure Method
      • Hotmelt - Hot melt
    • Key Specifications
      • FDA (U.S. Food & Drug Administration) and/or CFIA (Canadian Food Inspection Agency) : 175.105 - Listed under Food and Drug Administration CFR 175.105, Adhesives
    • Brand
      • Hysol
      • Loctite
      • Technomelt
    • Also Known As
      • Old Name - 1942 Hysol, Loctite Hysol 1942
    Specifications
    Cure Specs
    Cure Temperature (°C) 22
    Cure Time (min) 7,200
    Viscosity (cPs) 5,000 Test Method
    Set Time (min) Medium
    Softening Point (°C) 92 Test Method
    Work / Pot Time (min) 0.50
    Bond Strength
    General Bond Strength (psi) Excellent
    Peel Strength (piw) 44 (pli) Test Method
    Shear Strength (psi) 1,030, 1,335, 845, 1,375, 1,445, 1,065, 280, 340, 395, 155, 280, 500, 540, 440, 325, 520 Test Method
    Tensile Strength (psi) 250 Test Method
    Material Resistance
    High Temperature Resistance (°C) 61 Test Method
    Conductivity
    Dissipation Factor 0.02600 Test Method
    Dielectric Strength (V/mil) >1,100 Test Method
    Dielectric Constant 2.90 Test Method
    Surface Resistivity (O) 8.9e15 Test Method
    Volume Resistivity (O) 2.8e16 Test Method
    Hardness
    Elongation (%) 500 Test Method
    Other Properties
    Glass Transition Temp (Tg) (°C) -14 Test Method
    Specific Gravity 0.960 Test Method
    Business Information
    Shelf Life Details Store product in unopened container in a cool dry location. Ideal conditions are within the range 8 to 21 degrees C (46 to 70 degrees F) and are recommended for long term storage. Exposure to higher temperatures (greater than 28 degrees C) for prolonged periods should be avoided as extended exposure to warm conditions can adversely affect product properties.
  • Best Practices for Henkel Technomelt 1942

    *See Terms of Use Below

    1. Application

      Please read the operating instructions for the Hysol Hot Melt Applicator being used. Allow the applicator 5 - 10 minutes to reach operating temperature before applying the adhesive. Squeeze the trigger to dispense hot melt to one of the parts to be bonded. For best results, press the parts as soon as possible

      within the hot melt’s open time. After use, unplug the applicator and squeeze trigger twice to advance any semimolten adhesive into the melt chamber. This helps for quick start-up when the applicator is used next. Always use gloves when using the applicator. Henkel offers a complete line of reliable, portable, hand held applicators designed to accurately dispense all shaped hot melt formulations.

  • Comparable Materials for Henkel Technomelt 1942

    *See Terms of Use Below

    Spec Engine® Results

Popular Articles

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

Testing the effectiveness of surface treatments

Read Article

6 objects held together by adhesives you probably can't live without

Read Article

Lightweighting drives automotive adhesives demand

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article

Featured Ads

Gluespec Poll

When you're researching or sourcing materials online, what device are you using?
Softening Point Test Methods
Softening Point Unit Test Method
92°C ASTM E 28-67
Viscosity Test Methods
Viscosity Test Method Temperature
5,000 cPs Viscosity @ 350°F, cP, ASTM D 3236 177°C
Peel Strength Test Methods
Peel Strength Type Substrate Test Method
44 (pli) T-Peel strength Aluminum ASTM D 1876
Tensile Strength Test Methods
Tensile Strength Test Method
250 psi ASTM D 638
Shear Strength Test Methods
Shear Strength Type Cure Time Cure Temperature Substrate Test Humidity Test Method
1,030 psi 7,200 min 22°C Grit-Blasted Steel ASTM D1002, cured 5 days at 22°C
1,335 psi 7,200 min 22°C Aluminum ASTM D1002, cured 5 days at 22°C
845 psi 7,200 min 22°C Anodized Aluminum ASTM D1002, cured 5 days at 22°C
1,375 psi 7,200 min 22°C Stainless Steel ASTM D1002, cured 5 days at 22°C
1,445 psi 7,200 min 22°C Galvanized ASTM D1002, cured 5 days at 22°C
1,065 psi 7,200 min 22°C Zinc Dichromate ASTM D1002, cured 5 days at 22°C
280 psi 7,200 min 22°C Polycarbonate ASTM D1002, cured 5 days at 22°C
340 psi 7,200 min 22°C Nylon ASTM D1002, cured 5 days at 22°C
395 psi 7,200 min 22°C G-10 Epoxy ASTM D1002, cured 5 days at 22°C
155 psi 7,200 min 22°C LDPE ASTM D1002, cured 5 days at 22°C
280 psi 7,200 min 22°C Glass ASTM D1002, cured 5 days at 22°C
500 psi Block shear strength 1,440 min 25°C PVC 50 % ASTM D4501, 24 Hour RTC, 68°F/50%RH
540 psi Block shear strength 1,440 min 25°C Valox 50 % ASTM D4501, 24 Hour RTC, 68°F/50%RH
440 psi Block shear strength 1,440 min 25°C HD Polyethylene 50 % ASTM D4501, 24 Hour RTC, 68°F/50%RH
325 psi Block shear strength 1,440 min 25°C Polypropylene 50 % ASTM D4501, 24 Hour RTC, 68°F/50%RH
520 psi Block shear strength 1,440 min 25°C ABS 50 % ASTM D4501, 24 Hour RTC, 68°F/50%RH
High Temperature Resistance Test Methods
High Temperature Resistance Test Method
61°C ASTM D 4498
Dielectric Constant Test Methods
Dielectric Constant Test Method
2.90 MIL 1-16923. K
Dielectric Strength Test Methods
Dielectric Strength Test Method
>1,100 V/mil ASTM D149
Dissipation Factor Test Methods
Dissipation Factor Test Method
0.02600 ASTM D 150
Surface Resistivity Test Methods
Surface Resistivity Test Method
8.9e15 ASTM D 257
Volume Resistivity Test Methods
Volume Resistivity Test Method
2.8e16 ASTM D 257
Elongation Test Methods
Elongation Test Method
500 % ASTM D 638
Glass Transition Temp (Tg) Test Methods
Glass Transition Temp (Tg) Glass Transition Temperature (Tg) Test Method
-14°C ASTM E 1640
Specific Gravity Test Methods
Specific Gravity Temperature Test Method
0.960 25°C ASTM D 792