• Description for Loxeal 86-54

    Loxeal 86-54 is a 1-Part Anaerobic Methacrylate Liquid used to Adhere Mon metal materials, Metal surfaces and Steel

    *See Terms of Use Below

    Chemical Resistance Highly resistant to gases, Chemical Resistance: Fluid Resistance: Highly resistant to water, Highly resistant to hydrocarbons, Chemical Resistance: Fluid Resistance: Water/glycol 50% resistance, Highly resistant to many chemicals, Gasoline resistance
    Application Type Bond, Locking, Sealing
    1 Part or 2 Part 1-Part
    Material Form Liquid
    Substrate Metal surfaces, Steel, Bolt M10 x 20 Zn
    Industry For locking and sealing thread connections
    Manufacturer Loxeal
    Chemistry Methacrylate
    Cure Method Anaerobic, Room temperature cure
    Cure Temperature (°C) 25, 25
    Gap Fill (in) 0.012
    Cure Time (min) 180 to 360, 360 to 720, 60 to 180, 1,440 to 2,160
    Viscosity (cPs) High, 8,000 to 24,000
    Fluorescent Under blue light
    Color Green
    Torque (psi) 40 - 50 N m, 45 - 55 N m
    Oil Resistance Highly resistant to oils, Motor oil resistance, Gear box oil resistance, Brakes oil resistance
    High Temperature Resistance (°C) Highly resistant to heat, 150
    Low Temperature Resistance (°C) -55
  • Technical Data for Loxeal 86-54

    Overview
    • Chemical Resistance
      • Chemical Resistance : Fluid Resistance : Water Resistance - Water/glycol 50% resistance, Highly resistant to water
      • Chemical Resistance - Gasoline resistance, Highly resistant to many chemicals, Highly resistant to hydrocarbons, Highly resistant to gases
    • Application Type
    • 1 Part or 2 Part
      • 1-Part
    • Material Form
      • Liquid
    • Substrate
      • Metal - Metal surfaces
      • Steel
      • Zinc - Bolt M10 x 20 Zn
      • Other - Mon metal materials
    • Industry
      • Mechanical Fastening Parts - For locking and sealing thread connections
    • Chemistry
    • Cure Method
      • Room Temperature / Air Dry - Room temperature cure
      • Anaerobic
    • Color
      • Green
    Specifications
    Cure Specs
    Cure Temperature (°C) 25, 25 Test Method
    Gap Fill (in) 0.012
    Cure Time (min) 180 to 360, 360 to 720, 60 to 180, 1,440 to 2,160 Test Method
    Viscosity (cPs) High, 8,000 to 24,000 Test Method
    Fixture or Handling Strength Time (min) 15 to 30 Test Method
    Fluorescent Under blue light
    Thixotropic Thixotropic
    Bond Strength
    Torque (psi) 40 - 50 N m, 45 - 55 N m
    General Bond Strength (psi) High strength
    Shear Strength (psi) 2,176 to 3,626 Test Method
    Material Resistance
    Non-Corrosive Highly resistant to corrosion
    Oil Resistance Highly resistant to oils, Motor oil resistance, Gear box oil resistance, Brakes oil resistance
    Environmental Resistance Environmental resistance
    High Temperature Resistance (°C) Highly resistant to heat, 150 Test Method
    Low Temperature Resistance (°C) -55 Test Method
    Vibration Resistance/Shock Resistance Highly resistant to vibrations
    Other Properties
    Flash Point (°F) 212.0
    Business Information
    Shelf Life Details 1 year in original unopened packaging
    Shelf Life Temperature (°F) 77
    Shelf Life (mon) 12
    Not Good For
    Don't Use For Can damage coating
    Don't Use With Can damage some elastomers, Can damage some plastics, Some thermoplastics
  • Best Practices for Loxeal 86-54

    *See Terms of Use Below

    1. Surface Preparation

      Clean and degrease parts before bonding with Loxeal Cleaner 10.

    2. Application

      Apply product to fill completely the gap, assemble parts and hold on for curing time.

      For application on non metal materials, contact Loxeal Technical Service.

    3. Curing

      Curing rate depends on the assembly clearance, material surfaces and temperature. Functional strength is usually reached in 1 - 3 hours and full curing takes 24 - 36 hours. In case of passive surfaces and/or low temperature a fast cure can be obtained using Loxeal activator 11.

    4. Removal

      For disassembly, use normal tools and eventually heat pieces at +150°C/+250°C, remove any residue of cured product mechanically and clean parts with Acetone.

  • Comparable Materials for Loxeal 86-54

    *See Terms of Use Below

    Spec Engine® Results

Popular Articles

What Projects Require Custom Adhesive Formulations and Why?

Read Article

Testing the effectiveness of surface treatments

Read Article

Anaerobic Adhesives

Read Article

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article

Featured Ads

Gluespec Poll

Who do you read or follow for engineering news and entertainment?
Cure Temperature Test Methods
Cure Temperature Cure Time Test Method
25°C Bolt M10 x 20 Zn - quality 8.8 - nut h = 0,8 d, Functional cure
25°C Bolt M10 x 20 Zn - quality 8.8 - nut h = 0,8 d, Full cure
Cure Time Test Methods
Cure Time Test Method
180 to 360 min Bolt M10 x 20 Zn - quality 8.8 - nut h = 0,8 d, Functional cure
360 to 720 min Bolt M10 x 20 Zn - quality 8.8 - nut h = 0,8 d, Full cure
60 to 180 min Functional strength, Curing
1,440 to 2,160 min Full curing
Fixture or Handling Strength Time Test Methods
Fixture or Handling Strength Time Fixture-Handling Strength Test Method Fixture-Handling Strength Time Temperature
15 to 30 min Bolt M10 x 20 Zn - quality 8.8 - nut h = 0,8 d, Handling cure time 25°C
Viscosity Test Methods
Viscosity Temperature
High
8,000 to 24,000 cPs 25°C
Shear Strength Test Methods
Shear Strength Cure Temperature Substrate Test Method
2,176 to 3,626 psi 25°C Bolt M10 x 20 Zn Curing, ISO 10123, quality 8.8 - nut h = 0,8 d
High Temperature Resistance Test Methods
High Temperature Resistance Test Method
Highly resistant to heat
150°C Bolt M10 x 20 Zn - quality 8.8 - nut h = 0,8 d at +25°C
Low Temperature Resistance Test Methods
Low Temperature Resistance Test Method
-55°C Bolt M10 x 20 Zn - quality 8.8 - nut h = 0,8 d at +25°C