Description for Wevo Casting Resin PD 445
Wevo Casting Resin PD 445 is a 2-Part Resin/Hardener Polyurethane Liquid used to Cast and Mold Glass, Metal and PlasticChemical Resistance Outstanding Chemical Resistance Application Type Casting, Encapsulating 1 Part or 2 Part 2-Part Material Form Liquid Substrate Glass, Metal, Plastic Industry Electrical and Electronic Components, Sensors, SMD-equipped PCBs Manufacturer Wevo Chemistry Polyurethane Cure Method Resin/Hardener, Room temperature cure Cure Temperature (°C) 25 Cure Time (min) 720 to 1,440 Viscosity (cPs) 1,800 to 2,200 (mPa·s) High Temperature Resistance (°C) 120 Low Temperature Resistance (°C) -60 Volume Resistivity (O) 4.2e14 (ohm •cm) -
Technical Data for Wevo Casting Resin PD 445
Overview
-
Chemical Resistance
- Chemical Resistance - Outstanding Chemical Resistance
-
Application Type
- Casting / Moldmaking - Casting
- Pottant / Encapsulant - Encapsulating
-
1 Part or 2 Part
- 2-Part
-
Material Form
- Liquid
-
Industry
- Electronics - Electrical and Electronic Components
- Sensors
- Printed Circuit Board (PCB) - SMD-equipped PCBs
-
Chemistry
-
Cure Method
- Room Temperature / Air Dry - Room temperature cure
- 2-Part Cure - Resin/Hardener
Specifications
Cure Specs
Cure Temperature (°C) 25 Cure Time (min) 720 to 1,440 Viscosity (cPs) 1,800 to 2,200 (mPa·s) Test Method Linear Shrinkage (%) 0.60 Work / Pot Time (min) 30 Test Method Mix Ratio 100:20 (by weight) Bond Strength
General Bond Strength (psi) Very good adhesion Tensile Strength (psi) 1 (N/mm²) Test Method Material Resistance
High Temperature Resistance (°C) 120 Low Temperature Resistance (°C) -60 Conductivity
Dissipation Factor 0.01400 Test Method Dielectric Strength (V/mil) 20 (kV/mm) Test Method Dielectric Constant 3.00, Very low and stable Test Method Thermal Conductivity (W/m°K) 0.20 Test Method Surface Resistivity (O) > 10(16) (ohm) Test Method Volume Resistivity (O) 4.2e14 (ohm •cm) Test Method Hardness
Shore A Hardness 25 to 30 Test Method Elongation (%) 140 Test Method Flexibility Highly flexible Modulus (psi) 2 (N/mm²) Test Method Other Properties
Glass Transition Temp (Tg) (°C) -65 Test Method Coefficient of Thermal Expansion (CTE) 80 (ppm/K), 220 (ppm/K) Test Method Business Information
Shelf Life Details Shelf life in original closed cans or drums, dry storage between 15°C and 25°C, 6 months. Shelf Life Temperature (°F) 59 to 77 Shelf Life (mon) 6 -
-
Best Practices for Wevo Casting Resin PD 445
-
Comparable Materials for Wevo Casting Resin PD 445
Spec Engine® Results
Popular Articles
Characteristics of MMAs
Read ArticleTesting the effectiveness of surface treatments
Read ArticleInfographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleThe effectiveness of adhesives in the wind power industry
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

Viscosity Test Methods
Viscosity | Temperature |
---|---|
1,800 to 2,200 (mPa·s) | 22°C |
Work / Pot Time Test Methods
Work / Pot Time | Test Method | Temperature |
---|---|---|
30 min | 70g | 25°C |
Tensile Strength Test Methods
Tensile Strength | Test Method |
---|---|
1 (N/mm²) | ISO 527-2 |
Dielectric Constant Test Methods
Dielectric Constant | Temperature | Test Method |
---|---|---|
3.00 | 23°C | at 50 Hz, IEC 60250 VDE 0303, TI.4 |
Very low and stable |
Dielectric Strength Test Methods
Dielectric Strength | Test Method |
---|---|
20 (kV/mm) | IEC 60243-1 VDE 0303, TI.2 |
Dissipation Factor Test Methods
Dissipation Factor | Temperature | Test Method |
---|---|---|
0.01400 | 23°C | at 50 Hz, IEC 60250 VDE 0303, TI.4 |
Surface Resistivity Test Methods
Surface Resistivity | Temperature | Test Method |
---|---|---|
> 10(16) (ohm) | 23°C | 50% r.h., IEC 60093 VDE 0303, TI.30 |
Thermal Conductivity Test Methods
Thermal Conductivity | Test Method |
---|---|
0.20 W/m°K | ISO 8894 |
Volume Resistivity Test Methods
Volume Resistivity | Temp (°C) | Test Method |
---|---|---|
4.2e14 (ohm •cm) | 23°C | 50% r.h., IEC 60093 VDE 0303, TI.30 |
Elongation Test Methods
Elongation | Test Method |
---|---|
140 % | at break, ISO 527-2 |
Modulus Test Methods
Modulus | Test Method |
---|---|
2 (N/mm²) | Elasticity, ISO 527-2 |
Shore A Hardness Test Methods
Shore A Hardness | Shore Hardness Test Method |
---|---|
25 to 30 | ISO 868, DIN 53505 |
Coefficient of Thermal Expansion (CTE) Test Methods
Coefficient of Thermal Expansion (CTE) | CTE Temperature (°C) | CTE Test Method |
---|---|---|
80 (ppm/K) | <-70°C | TMA |
220 (ppm/K) | >-60°C | TMA |
Glass Transition Temp (Tg) Test Methods
Glass Transition Temp (Tg) | Glass Transition Temperature (Tg) Test Method |
---|---|
-65°C | TMA |