Henkel Bergquist Gap Pad TGP 1000VOUS Datasheet Henkel Bergquist Gap Pad TGP 1000VOUS

Information provided by Gluespec
  • Description for Henkel Bergquist Gap Pad TGP 1000VOUS

    Ultra Conformable, Thermally Conductive Material for Filling Air Gaps .Electrically isolating, Puncture, Shear and Tear resistant.

    *See Terms of Use Below

    Brand Bergquist
    Application Type Filling Air Gaps, Gap Pad, TIM (Thermal Interface Material)
    1 Part or 2 Part 1-Part
    Material Form Sheet form, Pad, Die-cut parts
    Industry Magnetic components, Heat sink, Heat-generating semiconductors, Computer, Telecommunications, Power conversion, Radar, Guidance Systems, Peripherals
    Manufacturer Henkel
    Chemistry Fiberglass Reinforcement, Silicone
    Cure Method Pressure Sensitive
    Color Mauve, Pink
    Puncture Resistance (g) Puncture resistant
    High Temperature Resistance (°C) 200
    Low Temperature Resistance (°C) -60
    Volume Resistivity (O) 1e11 (Ohm-meter)
    Density (g/cm³) 1.6 (g/cc)
    Key Specifications UL (Underwriters Laboratory), ULC (Underwriters Laboratories of Canada), NFPA (National Fire Protection Association): UL 94: Flammability, U.L. 94 V-0
  • Technical Data for Henkel Bergquist Gap Pad TGP 1000VOUS

    Overview
    • Application Type
      • Thermal Interface Material (TIM) - TIM (Thermal Interface Material)
      • Gap Filler - Filling Air Gaps
      • Gap Pad
    • 1 Part or 2 Part
      • 1-Part
    • Material Form
      • Other - Sheet form, Die-cut parts
      • Pad
    • Industry
      • Semiconductor - Heat-generating semiconductors
      • Storage & Graphics - Computer, Peripherals
      • Telecom / Datacom - Telecommunications
      • Power Conversion Systems - Power conversion
      • Radar
      • Guidance Systems
      • Heat sink
      • Magnet - Magnetic components
      • Other - Thermal management
    • Chemistry
      • Other - Fiberglass Reinforcement
      • Silicone
    • Cure Method
      • Pressure Sensitive (min) - Pressure Sensitive
    • Color
      • Pink
      • Other - Mauve
    • Key Specifications
      • UL (Underwriters Laboratory), ULC (Underwriters Laboratories of Canada), NFPA (National Fire Protection Association) : UL 94 : V0 - Flammability, U.L. 94 V-0
    • Brand
      • Bergquist
    • Also Known As
      • Old Name - Gap Pad VO Ultra Soft
    Specifications
    Bond Strength
    Shear Strength (psi) Shear resistant
    Tear Strength (piw) Tear resistant
    Material Resistance
    Puncture Resistance (g) Puncture resistant
    High Temperature Resistance (°C) 200 Test Method
    Low Temperature Resistance (°C) -60 Test Method
    Vibration Resistance/Shock Resistance Excellent low-stress vibration dampening, Shock absorbing
    Conductivity
    Dielectric Strength (V/mil) Electrically isolating, 6000 (VAC) Test Method
    Dielectric Constant 5.50 Test Method
    Thermal Conductivity (W/m°K) Thermally conductive, 1.00 Test Method
    Volume Resistivity (O) 1e11 (Ohm-meter) Test Method
    Hardness
    Shore OO Hardness 5 Test Method
    Flexibility Ultra Conformable, Low hardness
    Modulus (psi) 8 Test Method
    Other Properties
    Density (g/cm³) 1.6 (g/cc) Test Method
    Business Information
    Shelf Life Details Store product in the unopened container in a dry location. Storage information may be indicated on the product container labeling; Optimal Storage: 25ºC (±3), 50% RH (±10) for a 12 months shelf life.
    Shelf Life Temperature (°F) 72 to 82
    Shelf Life (mon) 12
  • Best Practices for Henkel Bergquist Gap Pad TGP 1000VOUS

    *See Terms of Use Below

  • Comparable Materials for Henkel Bergquist Gap Pad TGP 1000VOUS

    *See Terms of Use Below

    Spec Engine® Results

Popular Articles

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

Electrically Conductive Adhesives

Read Article

Testing the effectiveness of surface treatments

Read Article

6 objects held together by adhesives you probably can't live without

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article

Featured Ads

Gluespec Poll

Who do you read or follow for engineering news and entertainment?
High Temperature Resistance Test Methods
High Temperature Resistance Test Method
200°C Operating Temperature
Low Temperature Resistance Test Methods
Low Temperature Resistance Test Method
-60°C Operating Temperature
Dielectric Constant Test Methods
Dielectric Constant Test Method
5.50 1000 Hz, ASTM D150, Cured
Dielectric Strength Test Methods
Dielectric Strength Test Method
Electrically isolating
6000 (VAC) Dielectric Breakdown Voltage, ASTM D149, Cured
Thermal Conductivity Test Methods
Thermal Conductivity Test Method
Thermally conductive
1.00 W/m°K ASTM D5470
Volume Resistivity Test Methods
Volume Resistivity Test Method
1e11 (Ohm-meter) ASTM D257, Cured
Modulus Test Methods
Modulus Test Method
8 psi Young's, ASTM D575
Shore OO Hardness Test Methods
Shore OO Hardness Shore Hardness Test Method
5 30-sec delay value, ASTM D2240, Bulk rubber, cured
Density Test Methods
Density Test Method
1.6 (g/cc) Bulk rubber, ASTM D792, cured