Description for Henkel Bergquist Gap Pad TGP 1000VOUS
Ultra Conformable, Thermally Conductive Material for Filling Air Gaps .Electrically isolating, Puncture, Shear and Tear resistant.Brand Bergquist Application Type Filling Air Gaps, Gap Pad, TIM (Thermal Interface Material) 1 Part or 2 Part 1-Part Material Form Sheet form, Pad, Die-cut parts Industry Magnetic components, Heat sink, Heat-generating semiconductors, Computer, Telecommunications, Power conversion, Radar, Guidance Systems, Peripherals Manufacturer Henkel Chemistry Fiberglass Reinforcement, Silicone Cure Method Pressure Sensitive Color Mauve, Pink Puncture Resistance (g) Puncture resistant High Temperature Resistance (°C) 200 Low Temperature Resistance (°C) -60 Volume Resistivity (O) 1e11 (Ohm-meter) Density (g/cm³) 1.6 (g/cc) Key Specifications UL (Underwriters Laboratory), ULC (Underwriters Laboratories of Canada), NFPA (National Fire Protection Association): UL 94: Flammability, U.L. 94 V-0 -
Technical Data for Henkel Bergquist Gap Pad TGP 1000VOUS
Overview
-
Application Type
- Thermal Interface Material (TIM) - TIM (Thermal Interface Material)
- Gap Filler - Filling Air Gaps
- Gap Pad
-
1 Part or 2 Part
- 1-Part
-
Material Form
- Other - Sheet form, Die-cut parts
- Pad
-
Industry
- Semiconductor - Heat-generating semiconductors
- Storage & Graphics - Computer, Peripherals
- Telecom / Datacom - Telecommunications
- Power Conversion Systems - Power conversion
- Radar
- Guidance Systems
- Heat sink
- Magnet - Magnetic components
- Other - Thermal management
-
Chemistry
- Other - Fiberglass Reinforcement
- Silicone
-
Cure Method
- Pressure Sensitive (min) - Pressure Sensitive
-
Color
- Pink
- Other - Mauve
-
Key Specifications
- UL (Underwriters Laboratory), ULC (Underwriters Laboratories of Canada), NFPA (National Fire Protection Association) : UL 94 : V0 - Flammability, U.L. 94 V-0
-
Brand
- Bergquist
-
Also Known As
- Old Name - Gap Pad VO Ultra Soft
Specifications
Bond Strength
Shear Strength (psi) Shear resistant Tear Strength (piw) Tear resistant Material Resistance
Puncture Resistance (g) Puncture resistant High Temperature Resistance (°C) 200 Test Method Low Temperature Resistance (°C) -60 Test Method Vibration Resistance/Shock Resistance Excellent low-stress vibration dampening, Shock absorbing Conductivity
Dielectric Strength (V/mil) Electrically isolating, 6000 (VAC) Test Method Dielectric Constant 5.50 Test Method Thermal Conductivity (W/m°K) Thermally conductive, 1.00 Test Method Volume Resistivity (O) 1e11 (Ohm-meter) Test Method Hardness
Shore OO Hardness 5 Test Method Flexibility Ultra Conformable, Low hardness Modulus (psi) 8 Test Method Other Properties
Density (g/cm³) 1.6 (g/cc) Test Method Business Information
Shelf Life Details Store product in the unopened container in a dry location. Storage information may be indicated on the product container labeling; Optimal Storage: 25ºC (±3), 50% RH (±10) for a 12 months shelf life. Shelf Life Temperature (°F) 72 to 82 Shelf Life (mon) 12 -
-
Best Practices for Henkel Bergquist Gap Pad TGP 1000VOUS
-
Comparable Materials for Henkel Bergquist Gap Pad TGP 1000VOUS
Spec Engine® Results
Popular Articles
Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation
Read ArticleElectrically Conductive Adhesives
Read ArticleTesting the effectiveness of surface treatments
Read Article6 objects held together by adhesives you probably can't live without
Read ArticleSponsored Articles
Unique Advantages of Contact Adhesives
Read ArticleUsing LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials
Read ArticleSylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:
Read ArticleCase Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive
Read ArticleFeatured Ads

High Temperature Resistance Test Methods
High Temperature Resistance | Test Method |
---|---|
200°C | Operating Temperature |
Low Temperature Resistance Test Methods
Low Temperature Resistance | Test Method |
---|---|
-60°C | Operating Temperature |
Dielectric Constant Test Methods
Dielectric Constant | Test Method |
---|---|
5.50 | 1000 Hz, ASTM D150, Cured |
Dielectric Strength Test Methods
Dielectric Strength | Test Method |
---|---|
Electrically isolating | |
6000 (VAC) | Dielectric Breakdown Voltage, ASTM D149, Cured |
Thermal Conductivity Test Methods
Thermal Conductivity | Test Method |
---|---|
Thermally conductive | |
1.00 W/m°K | ASTM D5470 |
Volume Resistivity Test Methods
Volume Resistivity | Test Method |
---|---|
1e11 (Ohm-meter) | ASTM D257, Cured |
Modulus Test Methods
Modulus | Test Method |
---|---|
8 psi | Young's, ASTM D575 |
Shore OO Hardness Test Methods
Shore OO Hardness | Shore Hardness Test Method |
---|---|
5 | 30-sec delay value, ASTM D2240, Bulk rubber, cured |
Density Test Methods
Density | Test Method |
---|---|
1.6 (g/cc) | Bulk rubber, ASTM D792, cured |