• Description for Loxeal 59-30

    Loxeal 59-30 is a 1-Part Acetic curing Silicone Paste used to Seal

    *See Terms of Use Below

    Chemical Resistance Resists to several chemicals, Chemical Resistance: Fluid Resistance: Resists to water, Resists to LPG, Resists to gas
    Application Type Sealant
    1 Part or 2 Part 1-Part
    Material Form Paste
    Industry Suitable for sealing gear boxes flanges, Suitable for sealing gear boxes flanges, Suitable for sealing motors flanges, Suitable for sealing motors flanges, Suitable for sealing compressors flanges, Suitable for sealing pumps flanges
    Manufacturer Loxeal
    Chemistry Silicone
    Cure Method Acetic curing, Moisture, Room Temperature
    Cure Temperature (°C) 23
    Cure Time (min) 120 to 240, 720 to 1,440, >10,080
    Color Red/black, Red/black
    Oil Resistance Resists to oils
    High Temperature Resistance (°C) Resists to thermal shocks, 250, 300
    Low Temperature Resistance (°C) -60
  • Technical Data for Loxeal 59-30

    Overview
    • Chemical Resistance
      • Chemical Resistance : Fluid Resistance : Water Resistance - Resists to water
      • Chemical Resistance - Resists to several chemicals, Resists to LPG, Resists to gas
    • Application Type
    • 1 Part or 2 Part
      • 1-Part
    • Material Form
      • Paste
    • Industry
      • Industrial - Suitable for sealing hot fluid pipes
      • Gears - Suitable for sealing gear boxes flanges
      • Flange - Suitable for sealing gear boxes flanges, Suitable for sealing motors flanges, Suitable for sealing compressors flanges, Suitable for sealing pumps flanges
      • Motors - Suitable for sealing motors flanges
    • Chemistry
    • Cure Method
      • Room Temperature / Air Dry - Room Temperature
      • Moisture / Condensation Cure - Moisture
      • Other - Acetic curing
    • Color
      • Black - Red/black
      • Red - Red/black
    Specifications
    Cure Specs
    Cure Temperature (°C) 23 Test Method
    Cure Time (min) 120 to 240, 720 to 1,440, >10,080 Test Method
    Fixture or Handling Strength Time (min) 60 to 120 Test Method
    Tack Free Time (min) 10 to 20 Test Method
    Bond Strength
    Tensile Strength (psi) 2.5 (MPa) Test Method
    Material Resistance
    Oil Resistance Resists to oils
    High Temperature Resistance (°C) Resists to thermal shocks, 250, 300 Test Method
    Low Temperature Resistance (°C) -60
    Vibration Resistance/Shock Resistance Resists to vibrations
    Hardness
    Shore A Hardness 27 to 37 Test Method
    Elongation (%) 300 to 600 Test Method
    Flexibility Extremely flexible
    Modulus (psi) 0.4 (MPa), 2.2 (Mpa) Test Method
    Other Properties
    Coefficient of Thermal Expansion (CTE) 0.05 (%/°C) Test Method
    Business Information
    Shelf Life Details 1 year at +25°C in original unopened packaging
    Shelf Life Temperature (°F) 77
    Shelf Life (mon) 12
  • Best Practices for Loxeal 59-30

    *See Terms of Use Below

    1. Surface Preparation

      Clean and degrease parts to bond with Loxeal Cleaner 10.

    2. Application

      Apply enough product to fill the gap.

    3. Curing

      The product is moisture curing therefore pieces shall be assembled rapidly. Allow full cure before putting stress on pieces assembled.

    4. Removal

      Sealed parts can be disassembled using normal tools.

  • Comparable Materials for Loxeal 59-30

    *See Terms of Use Below

    Spec Engine® Results

    Closest Results from this Manufacturer

Popular Articles

Silicones in LED Lighting | Gluespec

Read Article

What Are the Differences Between Adhesives and Sealants?

Read Article

Infographic: ENSURING A STRONG BOND - 6 Basic Methods of Surface Preparation

Read Article

Testing the effectiveness of surface treatments

Read Article

Sponsored Articles

Unique Advantages of Contact Adhesives

Read Article

Using LOCTITE® 454™ is a Valid Option for Engineers Working with a Wide Variety of Materials

Read Article

Sylgard 184 by DOW is the Top Choice for a Transparent, Silicone Encapsulant. Read Why:

Read Article

Case Study: Creating reliable, corrosion-free bonds with LORD® 406 acrylic adhesive

Read Article

Featured Ads

Gluespec Poll

When you're researching or sourcing materials online, what device are you using?
Cure Temperature Test Methods
Cure Temperature Cure Time Test Method
23°C UR 50%
Cure Time Test Methods
Cure Time Test Method
120 to 240 min Functional cure
720 to 1,440 min Full cure
>10,080 min UR 50%
Fixture or Handling Strength Time Test Methods
Fixture or Handling Strength Time Fixture-Handling Strength Test Method
60 to 120 min Curing
Tack Free Time Test Methods
Tack Free Time Test Method
10 to 20 min Curing
Tensile Strength Test Methods
Tensile Strength Cure Time Cure Temperature Test Method
2.5 (MPa) >10,080 min 23°C ASTM D-412, UR 50%
High Temperature Resistance Test Methods
High Temperature Resistance Test Method
Resists to thermal shocks
250°C
300°C Peaks
Elongation Test Methods
Elongation Test Method
300 to 600 % At break, ASTM D-412, After 7 days/ +23°C/ UR 50%
Modulus Test Methods
Modulus Test Method
0.4 (MPa) Young, After 7 days/ +23°C/ UR 50%
2.2 (Mpa) Compression modulus, ASTM D-575, After 7 days/ +23°C/ UR 50%
Shore A Hardness Test Methods
Shore A Hardness Shore Hardness Test Method
27 to 37 ASTM 2240, After 7 days/ +23°C/ UR 50%
Coefficient of Thermal Expansion (CTE) Test Methods
Coefficient of Thermal Expansion (CTE) CTE Temperature (°C) CTE Time CTE Test Method
0.05 (%/°C) 23°C >10,080 min UR 50%